PXI-5402
Modular Systems > National Instruments > PXI Waveform Generators
Description: | NI PXI-5402, 1 Channel, 14 Bits, 20 MHz, BNC Connector, PXI Waveform Generator |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments PXI-5402 PXI Waveform Generator
The National Instruments PXI-5402 (part numbers: 779655-01, 192887E-01L) is a 20 MHz PXI Waveform Generator designed to create various waveforms and standard functions. Boasting 14 bits of DAC resolution, the PXI-5402 offers incredible precision and fidelity for a wide range of applications. Designed with a singular analog output channel, this function generator is capable of producing signals ranging from -5 V to 5 V. The front panel of the device features 4 BNC female connectors, designated for analog output, PLL reference clock input, and trigger input / sample clock output.
A variety of common functions are possible with the NI PXI-5402. Sine, Square, and User-Defined functions have a maximum frequency of 20 MHz and a maximum sample rate of 400 MS/s. The maximum frequency of both Ramp and Triangle functions is 1 MHz, and they each have a maximum sample rate of 100 MS/s. The sample clock of the NI PXI-5402 Waveform Generator is an onboard VCXO clock with a maximum frequency of 100 MHz. By utilizing the TClk synchronization driver from National Instruments, the sample clocks from multiple SMC-based modules in a chassis can be synchronized.
In order to maintain precision, it is recommended to calibrate the PXI-5402 every two years. There are two calibration options with the waveform generator: self-calibration or external calibration. The self-calibration capability of the device is the best choice for calibrate the gain and offset, using an onboard 24 bit ADC. The external calibration option of the device should be used to correct the VCXO, voltage reference, and aspects of the self-calibration. The NI PXI-5402 has a 15 minute warm up time prior to calibration.
Physically, the PXI-5402 measures dimensions of 21.6 × 2.0 × 13.0 cm (8.5 × 0.8 × 5.1 in.) and weighs in at 351 g (12.4 oz). The device has an operating temperature range of 0 to +55 ºC and a storage temperature range of –25 to +85 ºC. Additional specifications for the PXI-5402 can be found in the manuals and datasheets under the "Manuals & PDFs" tab.
PXI-5402 Mature Status has been announced by National Instruments, but the waveform generator will still be available for purchase and repairs by Apex Waves.
Model | PXI-5402 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 779655-01, 192887E-01L |
Type | PXI Waveform Generator |
Maximum Bandwidth | 20 MHz |
Maximum Update Rate | 100 MS/s |
Analog Output Resolution | 14 bits |
Output Channels | 1 |
Warranty | Three Year Warranty |
PXI-5402 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for PXI-5402:
188524J-15L, 188524M-15L, 192378A-01, 192378B-01, 192378C-01, 192378H-01L, 192887A-01, 192887B-01, 192887C-01, 192887D-01L, 192887E-01L, 192887F-01L, 195176A-01, 200033A-01, 779655-01
National Instruments PXI-5402 Frequently Asked Questions
Question: Can the PXI-5402 generate pseudorandom noise or DC signals?
Answer: Yes, the PXI‑5402 is capable of generating psuedorandom noise and DC signals.
Question: What is the effective sample rate of the PXI 5402?
Answer: The PXI 5402 has a 400 MS/s effective sample rate.
Question: What is the sine and square wave generation rate on the NI PXI-5402?
Answer: The NI PXI-5402 has a 20 MHz sine and square wave generation.
Question: Is it possible to skip pulses with the PXI-5402?
Answer: No, to skip pulses, it is necessary to use an arbitary waveform generator or FPGA DIO.
PXI-5402 PDF Manuals
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI 5402 5406 CALIBRATION PROCEDURE.PDF
NI PXI PCI 5402 5406 SPECIFICATIONS.PDF
NI SIGNAL GENERATORS GETTING STARTED GUIDE.PDF
NOTE TO USERS RETROFITTING YOUR PXI MODULE.PDF
PCI PXI-5402 LETTER OF VOLATILITY.PDF
PXI-5402 Diagrams
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXI-5402
Modular Systems > National Instruments > PXI Waveform Generators
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments PXI-5402 PXI Waveform Generator
The National Instruments PXI-5402 (part numbers: 779655-01, 192887E-01L) is a 20 MHz PXI Waveform Generator designed to create various waveforms and standard functions. Boasting 14 bits of DAC resolution, the PXI-5402 offers incredible precision and fidelity for a wide range of applications. Designed with a singular analog output channel, this function generator is capable of producing signals ranging from -5 V to 5 V. The front panel of the device features 4 BNC female connectors, designated for analog output, PLL reference clock input, and trigger input / sample clock output.
A variety of common functions are possible with the NI PXI-5402. Sine, Square, and User-Defined functions have a maximum frequency of 20 MHz and a maximum sample rate of 400 MS/s. The maximum frequency of both Ramp and Triangle functions is 1 MHz, and they each have a maximum sample rate of 100 MS/s. The sample clock of the NI PXI-5402 Waveform Generator is an onboard VCXO clock with a maximum frequency of 100 MHz. By utilizing the TClk synchronization driver from National Instruments, the sample clocks from multiple SMC-based modules in a chassis can be synchronized.
In order to maintain precision, it is recommended to calibrate the PXI-5402 every two years. There are two calibration options with the waveform generator: self-calibration or external calibration. The self-calibration capability of the device is the best choice for calibrate the gain and offset, using an onboard 24 bit ADC. The external calibration option of the device should be used to correct the VCXO, voltage reference, and aspects of the self-calibration. The NI PXI-5402 has a 15 minute warm up time prior to calibration.
Physically, the PXI-5402 measures dimensions of 21.6 × 2.0 × 13.0 cm (8.5 × 0.8 × 5.1 in.) and weighs in at 351 g (12.4 oz). The device has an operating temperature range of 0 to +55 ºC and a storage temperature range of –25 to +85 ºC. Additional specifications for the PXI-5402 can be found in the manuals and datasheets under the "Manuals & PDFs" tab.
PXI-5402 Mature Status has been announced by National Instruments, but the waveform generator will still be available for purchase and repairs by Apex Waves.
Model | PXI-5402 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 779655-01, 192887E-01L |
Type | PXI Waveform Generator |
Maximum Bandwidth | 20 MHz |
Maximum Update Rate | 100 MS/s |
Analog Output Resolution | 14 bits |
Output Channels | 1 |
Warranty | Three Year Warranty |
PXI-5402 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXI-5402 Frequently Asked Questions
Question: Can the PXI-5402 generate pseudorandom noise or DC signals?
Answer: Yes, the PXI‑5402 is capable of generating psuedorandom noise and DC signals.
Question: What is the effective sample rate of the PXI 5402?
Answer: The PXI 5402 has a 400 MS/s effective sample rate.
Question: What is the sine and square wave generation rate on the NI PXI-5402?
Answer: The NI PXI-5402 has a 20 MHz sine and square wave generation.
Question: Is it possible to skip pulses with the PXI-5402?
Answer: No, to skip pulses, it is necessary to use an arbitary waveform generator or FPGA DIO.
PXI-5402 PDF Manuals & Diagrams
PXI-5402 PDF Manuals
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI 5402 5406 CALIBRATION PROCEDURE.PDF
NI PXI PCI 5402 5406 SPECIFICATIONS.PDF
NI SIGNAL GENERATORS GETTING STARTED GUIDE.PDF
NOTE TO USERS RETROFITTING YOUR PXI MODULE.PDF
PCI PXI-5402 LETTER OF VOLATILITY.PDF
PXI-5402 Diagrams
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."