PXI-8210 National Instruments Ethernet/Ultra Wide SCSI Interface | Apex Waves | ImagePXI-8210 National Instruments Ethernet/Ultra Wide SCSI Interface | Apex Waves | ImagePXI-8210 NewPXI-8210 | Legacy, Refurbished and New Surplus
PXI-8210 National Instruments Ethernet/Ultra Wide SCSI Interface | Apex Waves | Image
PXI-8210 National Instruments Ethernet/Ultra Wide SCSI Interface | Apex Waves | Image
PXI-8210 New
PXI-8210 | Legacy, Refurbished and New Surplus

PXI-8210

4.8/5 | 17 ratings

Modular Systems > National Instruments > Serial Interface Devices

Part Number PXI-8210
Manufacturer/Brand National Instruments
Description: PXI-8210, 40 Mbytes/s, Ethernet and Ultra Wide SCSI Interface
In Stock | Ships in 5-10 Days
(expedited shipping options available)
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXI-8210 Ethernet/Ultra Wide SCSI Interface

Feature with both Ultra-Wide SCSI and Fast Ethernet interfaces, the National Instruments PXI-8210 (Part Number: 777569-01) is a single add-in card. This interface supports 100Base-TX and Ethernet 10Base-T transfer protocols with an auto-negotiation capability, enabling the user to connect to their network at the maximum rate. In addition, the NI PXI-8210 has Ultra-Wide SCSI and SCSI-2 interfaces.

While operating in Ultra-Wide SCSI mode, this card offers up to 40 Mbytes/s transfer rates. The bus mastering capability can make it operate with transfer rates of up to 133 Mbytes/s across the CompactPCI local bus or PXI. With this device, the user will be able to utilize a 6 m (19.7 ft) cable. The National Instruments PXI-8210 allows operation of up to 15 different and separate SCSI devices. This model is compatible with both 8 and 16-bit SCSI devices. For 8-bit SCSI devices, this model comes equipped with an internal 50-contact low-density connector, while an External 68-contact high-density connector is provided to be used for 16/8-bit Ultra-Wide SCSI or SCSI-2.

This interface connects to as many as seven 8-bit, single-ended intelligent SCSI, SCSI-2, or SCSI-3 devices or up to 15, 16-bit single-ended devices including hard disks, scanners, printers, and CD-ROM drives. With a BIOS extension installed in the ROM socket, the NI PXI-8210 can boot from the Ethernet or SCSI device as well. For improved noise immunity, this model features active terminators on the SCSI bus. This model has a standard RJ-45 Ethernet connector for communications over Fast Ethernet.

PXI-8210 Obsolete Status has been announced by National Instruments, but the interface will still be available for purchase and repairs by Apex Waves.

ModelPXI-8210
Part Number777569-01
ManufacturerNational Instruments
TypeEthernet/Ultra Wide SCSI Interface
Maximum Throughput40 Mbytes/s
InterfacesUltra Wide SCSI and SCSI-2
Ethernet ConnectorRJ-45
Transfer Rates10 or 100 Mbits/s
Maximum Cable Length19.7 ft.
Warranty2-3 Year Warranty
PXI-8210 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the PXI-8210:

184609B-01, 184609C-01, 500687A-00, 777569-01


Associated NSNs for the PXI-8210:

5998-01-467-0141 (5998014670141)

National Instruments PXI-8210 Frequently Asked Questions

 

Question: What do the active terminators on the SCSI bus of the PXI-8210 accomplish?

 

Answer: The active terminators on the SCSI bus of the PXI-8210 enhance the noise immunity.

 

Question: How many devices can the NI PXI-8210 connect to simultaneously?

 

Answer: The NI PXI-8210 can connect to as many as seven 8-bit intelligent SCSI, SCSI-2, or SCSI-3 single-ended devices. This model can additionally connect to 15 16-bit-single-ended devices (eight of them can be 8-bit models); this includes printers, scanners, hard disks, and CD-ROM drives.

 

Question: Can differential SCSI devices be connected to the PXI-8210?

 

Answer: No, differential SCSI devices cannot be connected to the PXI-8210. If the user tries to do so this will harm the devices and the PXI-8210.

 

Question: How can the NI PXI-8210 be connected to the SCSI bus?

 

Answer: The NI PXI-8210 can be connected to the SCSI bus via an unshielded, low-density connector or a shielded, high-density connector.

  PXI-8210 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: LXI-8210, PAI-8210, PXJ-8210, PXK-8210, PXI-821P

PXI-8210



Modular Systems > National Instruments > Serial Interface Devices

PXI-8210
4.8/5 | 17 ratings

PXI-8210, 40 Mbytes/s, Ethernet and Ultra Wide SCSI Interface

In Stock | Ships in 5-10 Days
(expedited shipping options available)
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXI-8210 Ethernet/Ultra Wide SCSI Interface

Feature with both Ultra-Wide SCSI and Fast Ethernet interfaces, the National Instruments PXI-8210 (Part Number: 777569-01) is a single add-in card. This interface supports 100Base-TX and Ethernet 10Base-T transfer protocols with an auto-negotiation capability, enabling the user to connect to their network at the maximum rate. In addition, the NI PXI-8210 has Ultra-Wide SCSI and SCSI-2 interfaces.

While operating in Ultra-Wide SCSI mode, this card offers up to 40 Mbytes/s transfer rates. The bus mastering capability can make it operate with transfer rates of up to 133 Mbytes/s across the CompactPCI local bus or PXI. With this device, the user will be able to utilize a 6 m (19.7 ft) cable. The National Instruments PXI-8210 allows operation of up to 15 different and separate SCSI devices. This model is compatible with both 8 and 16-bit SCSI devices. For 8-bit SCSI devices, this model comes equipped with an internal 50-contact low-density connector, while an External 68-contact high-density connector is provided to be used for 16/8-bit Ultra-Wide SCSI or SCSI-2.

This interface connects to as many as seven 8-bit, single-ended intelligent SCSI, SCSI-2, or SCSI-3 devices or up to 15, 16-bit single-ended devices including hard disks, scanners, printers, and CD-ROM drives. With a BIOS extension installed in the ROM socket, the NI PXI-8210 can boot from the Ethernet or SCSI device as well. For improved noise immunity, this model features active terminators on the SCSI bus. This model has a standard RJ-45 Ethernet connector for communications over Fast Ethernet.

PXI-8210 Obsolete Status has been announced by National Instruments, but the interface will still be available for purchase and repairs by Apex Waves.

ModelPXI-8210
Part Number777569-01
ManufacturerNational Instruments
TypeEthernet/Ultra Wide SCSI Interface
Maximum Throughput40 Mbytes/s
InterfacesUltra Wide SCSI and SCSI-2
Ethernet ConnectorRJ-45
Transfer Rates10 or 100 Mbits/s
Maximum Cable Length19.7 ft.
Warranty2-3 Year Warranty
PXI-8210 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXI-8210 Frequently Asked Questions

 

Question: What do the active terminators on the SCSI bus of the PXI-8210 accomplish?

 

Answer: The active terminators on the SCSI bus of the PXI-8210 enhance the noise immunity.

 

Question: How many devices can the NI PXI-8210 connect to simultaneously?

 

Answer: The NI PXI-8210 can connect to as many as seven 8-bit intelligent SCSI, SCSI-2, or SCSI-3 single-ended devices. This model can additionally connect to 15 16-bit-single-ended devices (eight of them can be 8-bit models); this includes printers, scanners, hard disks, and CD-ROM drives.

 

Question: Can differential SCSI devices be connected to the PXI-8210?

 

Answer: No, differential SCSI devices cannot be connected to the PXI-8210. If the user tries to do so this will harm the devices and the PXI-8210.

 

Question: How can the NI PXI-8210 be connected to the SCSI bus?

 

Answer: The NI PXI-8210 can be connected to the SCSI bus via an unshielded, low-density connector or a shielded, high-density connector.

PXI-8210 PDF Manuals & Diagrams

  PXI-8210 PDF Manuals

ARCHIVED PXI-8210 INSTALLATION GUIDE.PDF


Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn