Part Number cDAQ-9136
Manufacturer/Brand National Instruments
Description: cDAQ-9136, 1.91 GHz Quad-Core, CompactDAQ Controller
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments cDAQ-9136 CompactDAQ Controller

The cDAQ-9136 is a quad-core CompactDAQ Controller by National Instruments. The cDAQ-9136 is available in two versions with different OS. Part number 784238-01 has Windows Embedded Standard 7 installed and part number 784239-01 has Linux Real-Time installed. This model can control synchronization and timing functions and is also used to transfer data between C Series devices and a computer. The cDAQ-9136 is a 4-slot DAQ Controller, so four C Series I/O modules can be connected simultaneously. This feature enables the customization of digital and analog channels and timers/counters to design custom CAN measurement and logging systems.

The cDAQ-9136 CompactDAQ Controller features a 4-core Intel processor. The processor type is Intel Atom E3845. The CPU frequency is 1.91 GHz, and it has a hard drive memory space of 32 GB. The cache of the cDAQ 9136 processor has a memory of 2 MB. This model features an internal RT clock with 200 ppm accuracy. The cDAQ-9136 features analog inputs. The number of channels and maximum rate of sampling depends upon the C Series module(s). The NI cDAQ-9136 has a timing accuracy of 50 ppm for the analog inputs. The maximum update rate is 1.6 MS/sec. This model supports both periodic and non-periodic AO waveform modes.

The cDAQ-9136 CompactDAQ Controller incorporates many ports/terminals for different functions. This model has 2 Ethernet ports that support the network interface. These ports are IEEE 802.3 compatible, with communication rates of 10 Mbps, 100 Mbps, and 1000 Mbps auto-negotiated. The cDAQ-9136 also has an RS-232 port for serial communication. The serial port can sustain up to +24 V of overvoltage. Three USB ports are also available in the cDAQ-9136. These USB ports have a Hi-Speed 2.0 interface, with a maximum data rate of 480 Mb per second.

The NI device weighs 1.3 oz, and measures 8.54 x 3.47 x 4.67 in. in physical dimensions. It has a maximum power consumption value of 40 W, with a voltage input range of 9 to 30 V. Additionally, the controller has a recommended operating temperature range of -20 to 55 °C, and a storage temperature range of -40 to 85 °C.

ModelcDAQ-9136
ManufacturerNational Instruments
Part Numbers784238-01, 784239-01
TypeCompactDAQ Controller
Slots4
Hard Drive Memory Size32 GB
Processor Core1.91 GHz Quad-Core Intel Atom
Dimensions8.64 x 3.47 x 4.67 in.
Weight4 lb., 1.3 oz.
WarrantyThree Year Warranty
cDAQ-9136 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for thecDAQ-9136:

155470B-03L, 155470B-04L, 159061A-11L, 159061A-12L, 159286A-01L, 159286A-02L, 159286B-01L, 159286B-02L, 159286C-01L, 159286C-02L, 159286D-01L, 159286D-02L, 784238-01, 784239-01

National Instruments cDAQ-9136 Frequently Asked Questions

 

Question: There are two part numbers listed for the cDAQ 9136 on the product page. Is there a difference between the part numbers?

Answer: Many NI products have several part numbers with slight differences. For example, part number 784238-01 for the cDAQ 9136 is compatible with Windows Embedded Standard 7 OS. However, part number 784239-01 is compatible with NI Linux Real-Time OS.

 

Question: What should I do if I have forgotten my password for the NI cDAQ-9136 and I need to format it?

Answer: The NI cDAQ-9136 has a RESET button which needs to be pressed and held for 10 seconds.


Question: Does LabVIEW 2014 support the cDAQ-9136?

Answer: The cDAQ-9136 can be used as a normal controller in any version of LabVIEW with DAQmx 15.1 or later installed (within reason.) However, real-time compatibility with the cDAQ-9136 was not introduced until LabVIEW Real-Time module 2015, which is only compatible with LabVIEW 2015. Thus, in order to use the cDAQ-9136 as a real-time controller, you'll need to have LabVIEW 2015 and LabVIEW real-time module 2015 or later. This note can be found in DAQmx 15.1 notes for supported devices.

 

Question: Can you use an HDMI cord with the NI cDAQ-9136?

Answer: HDMI cords are not compatible with the NI cDAQ-9136. It must be either active DVI or VGA.

  cDAQ-9136 PDF Manuals

Driver Downloads for cDAQ-9136






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: DDAQ-9136, CFAQ-9136, CDAQ-9Q36, CDAQ-913T, CDAQ-913Y

cDAQ-9136



Modular Systems > National Instruments > CompactDAQ

cDAQ-9136
4.5/5 | 16 ratings

cDAQ-9136, 1.91 GHz Quad-Core, CompactDAQ Controller

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments cDAQ-9136 CompactDAQ Controller

The cDAQ-9136 is a quad-core CompactDAQ Controller by National Instruments. The cDAQ-9136 is available in two versions with different OS. Part number 784238-01 has Windows Embedded Standard 7 installed and part number 784239-01 has Linux Real-Time installed. This model can control synchronization and timing functions and is also used to transfer data between C Series devices and a computer. The cDAQ-9136 is a 4-slot DAQ Controller, so four C Series I/O modules can be connected simultaneously. This feature enables the customization of digital and analog channels and timers/counters to design custom CAN measurement and logging systems.

The cDAQ-9136 CompactDAQ Controller features a 4-core Intel processor. The processor type is Intel Atom E3845. The CPU frequency is 1.91 GHz, and it has a hard drive memory space of 32 GB. The cache of the cDAQ 9136 processor has a memory of 2 MB. This model features an internal RT clock with 200 ppm accuracy. The cDAQ-9136 features analog inputs. The number of channels and maximum rate of sampling depends upon the C Series module(s). The NI cDAQ-9136 has a timing accuracy of 50 ppm for the analog inputs. The maximum update rate is 1.6 MS/sec. This model supports both periodic and non-periodic AO waveform modes.

The cDAQ-9136 CompactDAQ Controller incorporates many ports/terminals for different functions. This model has 2 Ethernet ports that support the network interface. These ports are IEEE 802.3 compatible, with communication rates of 10 Mbps, 100 Mbps, and 1000 Mbps auto-negotiated. The cDAQ-9136 also has an RS-232 port for serial communication. The serial port can sustain up to +24 V of overvoltage. Three USB ports are also available in the cDAQ-9136. These USB ports have a Hi-Speed 2.0 interface, with a maximum data rate of 480 Mb per second.

The NI device weighs 1.3 oz, and measures 8.54 x 3.47 x 4.67 in. in physical dimensions. It has a maximum power consumption value of 40 W, with a voltage input range of 9 to 30 V. Additionally, the controller has a recommended operating temperature range of -20 to 55 °C, and a storage temperature range of -40 to 85 °C.

ModelcDAQ-9136
ManufacturerNational Instruments
Part Numbers784238-01, 784239-01
TypeCompactDAQ Controller
Slots4
Hard Drive Memory Size32 GB
Processor Core1.91 GHz Quad-Core Intel Atom
Dimensions8.64 x 3.47 x 4.67 in.
Weight4 lb., 1.3 oz.
WarrantyThree Year Warranty
cDAQ-9136 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments cDAQ-9136 Frequently Asked Questions

 

Question: There are two part numbers listed for the cDAQ 9136 on the product page. Is there a difference between the part numbers?

Answer: Many NI products have several part numbers with slight differences. For example, part number 784238-01 for the cDAQ 9136 is compatible with Windows Embedded Standard 7 OS. However, part number 784239-01 is compatible with NI Linux Real-Time OS.

 

Question: What should I do if I have forgotten my password for the NI cDAQ-9136 and I need to format it?

Answer: The NI cDAQ-9136 has a RESET button which needs to be pressed and held for 10 seconds.


Question: Does LabVIEW 2014 support the cDAQ-9136?

Answer: The cDAQ-9136 can be used as a normal controller in any version of LabVIEW with DAQmx 15.1 or later installed (within reason.) However, real-time compatibility with the cDAQ-9136 was not introduced until LabVIEW Real-Time module 2015, which is only compatible with LabVIEW 2015. Thus, in order to use the cDAQ-9136 as a real-time controller, you'll need to have LabVIEW 2015 and LabVIEW real-time module 2015 or later. This note can be found in DAQmx 15.1 notes for supported devices.

 

Question: Can you use an HDMI cord with the NI cDAQ-9136?

Answer: HDMI cords are not compatible with the NI cDAQ-9136. It must be either active DVI or VGA.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn