PCI-6036E National Instruments Multifunction DAQ | Apex Waves | ImagePCI-6036E National Instruments Multifunction DAQ | Apex Waves | ImagePCI-6036E NewPCI-6036E | Legacy, Refurbished and New Surplus
PCI-6036E National Instruments Multifunction DAQ | Apex Waves | Image
PCI-6036E National Instruments Multifunction DAQ | Apex Waves | Image
PCI-6036E New
PCI-6036E | Legacy, Refurbished and New Surplus

PCI-6036E

4.7/5 | 11 ratings

Modular Systems > National Instruments > E Series

Part Number PCI-6036E
Manufacturer/Brand National Instruments
Description: PCI-6036E, 16-Bit, 16-Channel, 8 DIO, Multifunction DAQ
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PCI-6036E Multifunction DAQ

The NI PCI-6036E (Part number: 778465-01) is a low-cost Multifunction DAQ Device that uses E Series innovation to convey dependable, 16-bit securing for an extensive variety of applications. The PCI 6036E has sixteen single-ended or 8 differential input channels (with a 16-bit resolution) and two 16-bit output channels. This device additionally has 8 computerized I/O lines and two 24-bit, 20 MHz counter/clocks. The NI PCI-6036E can stream at a sampling rate of 200 kS/s or an output rate of 10 kS/s. Utilizing NI equipment and driver programming alternatives, the user has adaptable OS, application advancement condition, and application programming decisions. The user can finish their DAQ framework with NI signal molding to quantify any sort of sensor and voltage.

Utilizing software, the user can arrange the channels for two unique sorts of single-ended associations: RSE setup and NRSE design. The RSE setup is utilized for floating signal sources. For this situation, the DAQ PCI 6036E gives the reference ground point to the outer signal. The NRSE input arrangement is utilized for ground-referenced signal sources. For this situation, the outer signal supplies its own reference ground point and the PCI 6036E National Instruments does not need to supply one. The device is run using the NI-DAQmx driver softwatre.

The NI PCI-6036E has an onboard self-calibration feature, which is a precision voltage reference for calibration and measurement preciseness. The self-calibration feature is fully controlled by software and does not entail altering potentiometers. The calibration procedure for this device writing values to onboard calibration DACs or CalDACs. This E Series Multifunction DAQ can also be externally calibrated and has a recommended calibration interval of one year. The external calibration reference is between 6 and 10 V. It has a recommended warm-up time of 15 minutes. The NI device weighs 4 oz, and measures 6.9 x 4.2 in. in physical dimensions. It has a recommended operating temperature range of 0 to 55 °C, and a storage temperature range of –20 to 70 °C.

PCI-6036E End of Life Status has been announced by National Instruments, but the device will still be available for purchase and repairs at Apex Waves. 

ModelPCI-6036E
ManufacturerNational Instruments
Part Number778465-01
SeriesE Series
TypeMultifunction DAQ
Analog Input Channels16 single-ended or 8 differential
Analog Input Resolution16 bits
Dimensions6.9 in. × 4.2 in.
Weight4.0 oz.
WarrantyThree Year Warranty
PCI-6036E ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-6036E Frequently Asked Questions

 

Question: What is the voltage output range of the NI PCI-6036E?

 

Answer: The voltage output range of the NI PCI-6036E is ±10 V.

 

Question: What is the maximum working voltage of the DAQ PCI 6036E?

 

Answer: The maximum working voltage of the DAQ PCI 6036E is ±11 V, Installation Category I.

 

Question: Which accessories are recommended for use with the PCI 6036E National Instruments?

 

Answer: The PCI 6036E National Instruments can be used with the SCC signal conditioning accessories, the shielded SCB-68 Terminal Block and SH6868-EP cable, the shielded TB-2075 Terminal Block and SH6868-EP cable, or the CB-68LP Terminal Block and R6868 cable.

 

Question: How many RTSI trigger lines does the PCI 6036E have?

 

Answer: The PCI 6036E has seven RTSI trigger lines.

  PCI-6036E PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PXI-6036E, PDI-6036E, PCI-6036W, PCI-6036S, PCI-6036F

PCI-6036E



Modular Systems > National Instruments > E Series

PCI-6036E
4.7/5 | 11 ratings

PCI-6036E, 16-Bit, 16-Channel, 8 DIO, Multifunction DAQ

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PCI-6036E Multifunction DAQ

The NI PCI-6036E (Part number: 778465-01) is a low-cost Multifunction DAQ Device that uses E Series innovation to convey dependable, 16-bit securing for an extensive variety of applications. The PCI 6036E has sixteen single-ended or 8 differential input channels (with a 16-bit resolution) and two 16-bit output channels. This device additionally has 8 computerized I/O lines and two 24-bit, 20 MHz counter/clocks. The NI PCI-6036E can stream at a sampling rate of 200 kS/s or an output rate of 10 kS/s. Utilizing NI equipment and driver programming alternatives, the user has adaptable OS, application advancement condition, and application programming decisions. The user can finish their DAQ framework with NI signal molding to quantify any sort of sensor and voltage.

Utilizing software, the user can arrange the channels for two unique sorts of single-ended associations: RSE setup and NRSE design. The RSE setup is utilized for floating signal sources. For this situation, the DAQ PCI 6036E gives the reference ground point to the outer signal. The NRSE input arrangement is utilized for ground-referenced signal sources. For this situation, the outer signal supplies its own reference ground point and the PCI 6036E National Instruments does not need to supply one. The device is run using the NI-DAQmx driver softwatre.

The NI PCI-6036E has an onboard self-calibration feature, which is a precision voltage reference for calibration and measurement preciseness. The self-calibration feature is fully controlled by software and does not entail altering potentiometers. The calibration procedure for this device writing values to onboard calibration DACs or CalDACs. This E Series Multifunction DAQ can also be externally calibrated and has a recommended calibration interval of one year. The external calibration reference is between 6 and 10 V. It has a recommended warm-up time of 15 minutes. The NI device weighs 4 oz, and measures 6.9 x 4.2 in. in physical dimensions. It has a recommended operating temperature range of 0 to 55 °C, and a storage temperature range of –20 to 70 °C.

PCI-6036E End of Life Status has been announced by National Instruments, but the device will still be available for purchase and repairs at Apex Waves. 

ModelPCI-6036E
ManufacturerNational Instruments
Part Number778465-01
SeriesE Series
TypeMultifunction DAQ
Analog Input Channels16 single-ended or 8 differential
Analog Input Resolution16 bits
Dimensions6.9 in. × 4.2 in.
Weight4.0 oz.
WarrantyThree Year Warranty
PCI-6036E ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PCI-6036E Frequently Asked Questions

 

Question: What is the voltage output range of the NI PCI-6036E?

 

Answer: The voltage output range of the NI PCI-6036E is ±10 V.

 

Question: What is the maximum working voltage of the DAQ PCI 6036E?

 

Answer: The maximum working voltage of the DAQ PCI 6036E is ±11 V, Installation Category I.

 

Question: Which accessories are recommended for use with the PCI 6036E National Instruments?

 

Answer: The PCI 6036E National Instruments can be used with the SCC signal conditioning accessories, the shielded SCB-68 Terminal Block and SH6868-EP cable, the shielded TB-2075 Terminal Block and SH6868-EP cable, or the CB-68LP Terminal Block and R6868 cable.

 

Question: How many RTSI trigger lines does the PCI 6036E have?

 

Answer: The PCI 6036E has seven RTSI trigger lines.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn