PXI-2530 National Instruments Matrix Switch Module| Apex Waves | ImagePXI-2530 National Instruments Matrix Switch Module| Apex Waves | ImagePXI-2530 NewPXI-2530 | Legacy, Refurbished and New Surplus
PXI-2530 National Instruments Matrix Switch Module| Apex Waves | Image
PXI-2530 National Instruments Matrix Switch Module| Apex Waves | Image
PXI-2530 New
PXI-2530 | Legacy, Refurbished and New Surplus

PXI-2530

4.5/5 | 16 ratings

Modular Systems > National Instruments > PXI Multiplexer Modules

Part Number PXI-2530
Manufacturer/Brand National Instruments
Description: PXI-2530, 128-Channel, PXI Matrix Switch Module
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXI-2530 PXI Matrix Switch Module

Featured with three matrix and four multiplexer configurations, the National Instruments PXI-2530 (Part Number: 778660-01, 189291A-01) is a 128-Channel PXI Matrix Switch Module. This module offers up to 900 ch/s switching speed. The multiplexer configurations achievable with this model include: 32 x 1 (4-wire), 64 x 1 (2-wire), 128 x 1 (1-wire), etc. The matrix configurations possible are 4 x 16 (2-wire), 8 x 16 (1-wire), or 4 x 32 (1-wire). The device has a channel-to-channel maximum switching voltage of 60 VDC, 30 VACrms, CAT I, and a channel-to-ground maximum switching voltage of 60 VDC, 30 VACrms, CAT I. It has a maximum input current of 0.4 A per terminal, and a maximum switching input power of 10 W. The NI PXI-2530 is widely considered a viable front-end solution for high-speed measurement instruments like the PXI-4070 FlexDMM.

The reed relays incorporated have a mechanical life of 1 × 109 cycles and 555 μS relay operate/release time. With this Matrix Switch Module, the user can achieve >60 dB channel-to-channel isolation over a 200 kHz frequency band. To be utilized with the independent topology in any combination, the PXI-2530 offers eight interconnected banks of 16 x 1 (1-wire) multiplexers. To configure and program this module, the user can utilize the NI-SWITCH driver, which provides full functionality for every switch module. The NI PXI-2530 can also be used with the TB-2630, TB-2631, or TB-2632 Terminal Block to configure the Matrix Switch Module into different arrangements.

In any 50 Ω system and 1-wire configuration, this model can provide >15 and >3 MHz bandwidth while operating in 16 × 1 and 128 × 1 topologies respectively. For receiving trigger signals and to output trigger signals, the NI PXI-2530 can utilize either front panel or PXI trigger lines 0–7. The National Instruments PXI-2530 comes equipped with a 176-pin docking station plug front panel connector. The device has a recommended operating temperature of 0 °C to 55 °C. The device weighs 14 oz., and measures 8.5 x 0.8 x 5.1 in. in dimensions.

PXI-2530 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

ModelPXI-2530
ManufacturerNational Instruments
Part Number778660-01, 189291A-01
TypePXI Matrix Switch Module
Channels128
Banks8
Maximum Switching Speed900 ch/s
Dimensions8.5 x 0.8 x 5.1 in.
Weight14 oz.
WarrantyThree Year Warranty
PXI-2530 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PXI-2530:

151825A-01L, 188030D-01L, 189291A-01, 189291B-01, 189291C-01, 189291D-01, 189291E-01L, 778660-01

National Instruments PXI-2530 Frequently Asked Questions

 

Question: What type of front-panel connector does the NI PXI-2530 have?

 

Answer: The NI PXI-2530 has a 176-pin docking station plug.

 

Question: What is the pulse width of the PXI-2530?

 

Answer: The PXI-2530 has a programmable pulse width of 1 μs to 62 μs.

 

Question: What is the maximum current of the PXI-2530?

 

Answer: 400 mA is the maximum current of the PXI-2530.

 

Question: What is the typical channel-to-channel isolation for the PXI-2530?

 

Answer: The typical channel-to-channel isolation for the PXI-2530 is >60 dB at 200 kHz and >40 dB at 1 MHz.

  PXI-2530 PDF Manuals

  PXI-2530 Diagrams

Driver Downloads for PXI-2530






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PDI-2530, PCI-2530, PXK-2530, PXI-2Y30, PXI-253P

PXI-2530



Modular Systems > National Instruments > PXI Multiplexer Modules

PXI-2530
4.5/5 | 16 ratings

PXI-2530, 128-Channel, PXI Matrix Switch Module

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXI-2530 PXI Matrix Switch Module

Featured with three matrix and four multiplexer configurations, the National Instruments PXI-2530 (Part Number: 778660-01, 189291A-01) is a 128-Channel PXI Matrix Switch Module. This module offers up to 900 ch/s switching speed. The multiplexer configurations achievable with this model include: 32 x 1 (4-wire), 64 x 1 (2-wire), 128 x 1 (1-wire), etc. The matrix configurations possible are 4 x 16 (2-wire), 8 x 16 (1-wire), or 4 x 32 (1-wire). The device has a channel-to-channel maximum switching voltage of 60 VDC, 30 VACrms, CAT I, and a channel-to-ground maximum switching voltage of 60 VDC, 30 VACrms, CAT I. It has a maximum input current of 0.4 A per terminal, and a maximum switching input power of 10 W. The NI PXI-2530 is widely considered a viable front-end solution for high-speed measurement instruments like the PXI-4070 FlexDMM.

The reed relays incorporated have a mechanical life of 1 × 109 cycles and 555 μS relay operate/release time. With this Matrix Switch Module, the user can achieve >60 dB channel-to-channel isolation over a 200 kHz frequency band. To be utilized with the independent topology in any combination, the PXI-2530 offers eight interconnected banks of 16 x 1 (1-wire) multiplexers. To configure and program this module, the user can utilize the NI-SWITCH driver, which provides full functionality for every switch module. The NI PXI-2530 can also be used with the TB-2630, TB-2631, or TB-2632 Terminal Block to configure the Matrix Switch Module into different arrangements.

In any 50 Ω system and 1-wire configuration, this model can provide >15 and >3 MHz bandwidth while operating in 16 × 1 and 128 × 1 topologies respectively. For receiving trigger signals and to output trigger signals, the NI PXI-2530 can utilize either front panel or PXI trigger lines 0–7. The National Instruments PXI-2530 comes equipped with a 176-pin docking station plug front panel connector. The device has a recommended operating temperature of 0 °C to 55 °C. The device weighs 14 oz., and measures 8.5 x 0.8 x 5.1 in. in dimensions.

PXI-2530 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

ModelPXI-2530
ManufacturerNational Instruments
Part Number778660-01, 189291A-01
TypePXI Matrix Switch Module
Channels128
Banks8
Maximum Switching Speed900 ch/s
Dimensions8.5 x 0.8 x 5.1 in.
Weight14 oz.
WarrantyThree Year Warranty
PXI-2530 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXI-2530 Frequently Asked Questions

 

Question: What type of front-panel connector does the NI PXI-2530 have?

 

Answer: The NI PXI-2530 has a 176-pin docking station plug.

 

Question: What is the pulse width of the PXI-2530?

 

Answer: The PXI-2530 has a programmable pulse width of 1 μs to 62 μs.

 

Question: What is the maximum current of the PXI-2530?

 

Answer: 400 mA is the maximum current of the PXI-2530.

 

Question: What is the typical channel-to-channel isolation for the PXI-2530?

 

Answer: The typical channel-to-channel isolation for the PXI-2530 is >60 dB at 200 kHz and >40 dB at 1 MHz.

PXI-2530 PDF Manuals & Diagrams

  PXI-2530 PDF Manuals

NI PXI-2530 LETTER OF VOLATILITY.PDF

NI PXI-2530 SPECIFICATIONS.PDF

  PXI-2530 Diagrams

CU_PXI-2530.PDF


Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn