National Instruments PXI-4472 PXI Sound and Vibration Module
The PXI-4472 (Part number: 778279-01, 187123M-01L) Sound and Vibration Module by National Instruments comes with many beneficial features, such as a broad dynamic range, high-performing noise and distortion, and the capability to perform both synchronization and sampling at the same time. These features ensure the National Instruments PXI-4472 is ideal for applications like noise and vibration diagnostics, laboratory research, automotive test, machine condition monitoring, and various others. Other features like antialiasing filters, IEPE conditioning, and software-configurable AC/DC coupling guarantee that this module will complete precision measurements for numerous types of transducers with wide dynamic ranges.
The National Instruments PXI-4472 can be used with many types of transducers or sensors. The most used transducers are accelerometers for measuring linear acceleration or vibration and microphones for measuring sound pressure. DSA devices, such as the PXI-4472 Sound and Vibration Module, stay at their peak performance when they are not near power supplies, computer monitors, disk drives, etc. These types of devices will reduce the noise performance of the input channels. Furthermore, utilizing shielded coaxial or floating cables for every connection will additionally help decrease the noise. A minimum sampling rate of 21.6 kS/s will ensure that signal components in the bandwidth are obtained. This will be possible without aliasing or weakening by the digital filter.
There are eight analog input channels on the PXI-4472 Sound and Vibration Module, as well as 24 bit resolution, 25 ppm frequency accuracy, 10 Vpk input signal range, and a sample rate of 102.4 kS/s in 190.7. The PXI-4472 has SMB male analog I/O connectors, as well as SMB male digital trigger connectors.
PXI-4472 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves.
The PXI-4472 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXI-4472 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXI-4472 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXI-4472!
Model | PXI-4472 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 778279-01, 187123M-01L |
HTS Code | 8471804000 |
Series | DSA Devices |
Type | PXI Sound and Vibration Module |
Analog Input Channels | 8 |
High-Pass Filter Cutoff Frequency | 3.4 Hz |
Maximum Sample Rate | 102.4 kS/s |
Warranty | Three Year Warranty |
PXI-4472 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for PXI-4472:
18712.3, 187123-01, 187123A-01, 187123A-02, 187123B-01, 187123C-01, 187123D-01, 187123F-01, 187123G-01, 187123H-01, 187123J-01, 187123K-01, 187123L-01, 187123L-01L, 187123M-01L, 187123N-01L, 187123P-01L, 187123P-06L, 187123R-01L, 187123R-03L, 187123R-04L, 778279-01, 778664-01
National Instruments PXI-4472 Frequently Asked Questions
Question: Does the PXI-4472 offer antialiasing features?
Answer: Yes, the PXI-4472 has built-in antialiasing filters that automatically adjust to your sample rate.
Question: Does the PXI 4472 utilize IEPE signal conditioning?
Answer: Yes, the PXI 4472 incorporates IEPE (integrated electronic piezoelectric) signal conditioning.
Question: Does the NI PXI-4472 use modulating ADCs?
Answer: The NI PXI-4472 uses delta-sigma modulating ADCs to deliver low noise and low distortion.
Question: What software analysis tools are recommended for use with the NI PXI 4472?
Answer: The NI PXI 4472 can be used with the Sound and Vibration Toolkit, as well as a variety of other software analysis tools.
PXI-4472 PDF Manuals
ARCHIVED TRADITIONAL NI DAQ USER MANUAL.PDF
DAQ GETTING STARTED GUIDE FOR PXI PXI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
GUIDE D_INITIATION DAQ POUR PXI PXI EXPRESS.PDF
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI 4472 4472B 4474 LETTER OF VOLATILITY.PDF
NI 447X CALIBRATION PROCEDURE.PDF
NI DYNAMIC SIGNAL ACQUISITION USER MANUAL.PDF
PXI SOUND AND VIBRATION MODULES.PDF
C3A0 LIRE EN PREMIER GUIDE DE28099INSTALLATION DE NI DAQMX ET DES PC3A9RIPHC3A9RIQUES DAQ.PDF
PXI-4472 Diagrams
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXI-4472
Modular Systems > National Instruments > DSA Devices
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments PXI-4472 PXI Sound and Vibration Module
The PXI-4472 (Part number: 778279-01, 187123M-01L) Sound and Vibration Module by National Instruments comes with many beneficial features, such as a broad dynamic range, high-performing noise and distortion, and the capability to perform both synchronization and sampling at the same time. These features ensure the National Instruments PXI-4472 is ideal for applications like noise and vibration diagnostics, laboratory research, automotive test, machine condition monitoring, and various others. Other features like antialiasing filters, IEPE conditioning, and software-configurable AC/DC coupling guarantee that this module will complete precision measurements for numerous types of transducers with wide dynamic ranges.
The National Instruments PXI-4472 can be used with many types of transducers or sensors. The most used transducers are accelerometers for measuring linear acceleration or vibration and microphones for measuring sound pressure. DSA devices, such as the PXI-4472 Sound and Vibration Module, stay at their peak performance when they are not near power supplies, computer monitors, disk drives, etc. These types of devices will reduce the noise performance of the input channels. Furthermore, utilizing shielded coaxial or floating cables for every connection will additionally help decrease the noise. A minimum sampling rate of 21.6 kS/s will ensure that signal components in the bandwidth are obtained. This will be possible without aliasing or weakening by the digital filter.
There are eight analog input channels on the PXI-4472 Sound and Vibration Module, as well as 24 bit resolution, 25 ppm frequency accuracy, 10 Vpk input signal range, and a sample rate of 102.4 kS/s in 190.7. The PXI-4472 has SMB male analog I/O connectors, as well as SMB male digital trigger connectors.
PXI-4472 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves.
The PXI-4472 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXI-4472 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXI-4472 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXI-4472!
Model | PXI-4472 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 778279-01, 187123M-01L |
HTS Code | 8471804000 |
Series | DSA Devices |
Type | PXI Sound and Vibration Module |
Analog Input Channels | 8 |
High-Pass Filter Cutoff Frequency | 3.4 Hz |
Maximum Sample Rate | 102.4 kS/s |
Warranty | Three Year Warranty |
PXI-4472 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXI-4472 Frequently Asked Questions
Question: Does the PXI-4472 offer antialiasing features?
Answer: Yes, the PXI-4472 has built-in antialiasing filters that automatically adjust to your sample rate.
Question: Does the PXI 4472 utilize IEPE signal conditioning?
Answer: Yes, the PXI 4472 incorporates IEPE (integrated electronic piezoelectric) signal conditioning.
Question: Does the NI PXI-4472 use modulating ADCs?
Answer: The NI PXI-4472 uses delta-sigma modulating ADCs to deliver low noise and low distortion.
Question: What software analysis tools are recommended for use with the NI PXI 4472?
Answer: The NI PXI 4472 can be used with the Sound and Vibration Toolkit, as well as a variety of other software analysis tools.
PXI-4472 PDF Manuals & Diagrams
PXI-4472 PDF Manuals
ARCHIVED TRADITIONAL NI DAQ USER MANUAL.PDF
DAQ GETTING STARTED GUIDE FOR PXI PXI EXPRESS.PDF
DAQ GETTING STARTED READ ME FIRST NI DAQMX AND DAQ DEVICE INSTALLATION GUIDE.PDF
GUIDE D_INITIATION DAQ POUR PXI PXI EXPRESS.PDF
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI 4472 4472B 4474 LETTER OF VOLATILITY.PDF
NI 447X CALIBRATION PROCEDURE.PDF
NI DYNAMIC SIGNAL ACQUISITION USER MANUAL.PDF
PXI SOUND AND VIBRATION MODULES.PDF
C3A0 LIRE EN PREMIER GUIDE DE28099INSTALLATION DE NI DAQMX ET DES PC3A9RIPHC3A9RIQUES DAQ.PDF