PXI-5124 National Instruments Oscilloscope | Apex Waves | ImagePXI-5124 National Instruments Oscilloscope | Apex Waves | ImagePXI-5124 NewPXI-5124 | Legacy, Refurbished and New Surplus
PXI-5124 National Instruments Oscilloscope | Apex Waves | Image
PXI-5124 National Instruments Oscilloscope | Apex Waves | Image
PXI-5124 New
PXI-5124 | Legacy, Refurbished and New Surplus

PXI-5124

5/5 | 11 ratings

Oscilloscopes > National Instruments > Oscilloscopes

Part Number PXI-5124
Manufacturer/Brand National Instruments
Description: PXI-5124, 2 Input Channel, 150 MHz, 200 MS/s, Oscilloscope
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXI-5124 Oscilloscope

The National Instruments PXI-5124 (Part Numbers: 778757-01, 778757-02, 778757-03 778757-04, 191766A-02, 191766C-01, and 191766A-01) high-resolution digitizer has various configurations, including: 8 MB/channel Oscilloscope (Part Number: 778757-01), 32 MB/channel Oscilloscope (Part Number: 778757-02), 256 MB/channel Oscilloscope (Part Number: 778757-03), 512 MB/channel Oscilloscope (Part Number: 778757-04).

This oscilloscope highlights two 200 MS/s simultaneous tested data source channels with 2 input channels, 12-bit analog resolution, 150 MHz data transmission, and up to 512 MB of memory for each route in a smaller 3U PXI module. The NI PXI-5124 uses the rapid PCI bus and the scatter-gather bus mastering of the NI MITE ASIC to move information to the PC at speeds up to 100 times speedier than customary instrument interfaces. This helps drastically diminish general test time. With the Synchronization and Memory Core (SMC) design of the PXI-5124, the user can make mixed signal frameworks utilizing signal generators and advanced waveform generator/analyzers or manufacture a high-channel-count digitizer with sub-nanosecond synchronization between channels.

To accomplish inspecting rates different than 200 MS/s when utilizing the inner sample clock, the NI PXI-5124 crushes the examined information. When the user sets an inspecting rate of 50 MS/s, the NI PXI-5124 just stores one out of each four samples it gets from the ADCs to locally available memory. The NI PXI-5124 can test at rates of 200/n MS/s, where n is a whole number an incentive in the vicinity of 1 and 216 – 1. Since this model does not change the recurrence of the clock sent to the ADCs, it makes a sample clock for send out considering the successful examining rate that the user has arranged. The device has a warm-up time of 15 minutes before operation.Also, it has an external calibration interval of 2 years.

The PXI-5124 operates using the NI-SCOPE 2.7 driver software which provides features such as programming interfaces, documentation, and examples for Application Development Environments such as LabVIEW, LabWindows™/CVI™, Measurement Studio, Microsoft Visual C/C++, .NET (C# and VB.NET).The device has 3 BNC female connectors, 2 SMB Jack connectors, and a 9-pin mini-circular DIN connectors.

Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PXI-5124 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!

ModelPXI-5124
ManufacturerNational Instruments
Part Numbers778757-01, 778757-02, 778757-03 778757-04, 
191766A-02, 191766C-01, 191766A-01
HTS Code8471804000
TypeOscilloscope
Onboard Memory Size8, 32, 256, or 512 MB/channel
Input Channels2
Analog Input Resolution12 bits
Maximum Bandwidth150 MHz
WarrantyThree Year Warranty
PXI-5124 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the PXI-5124:

188524G-04L, 188524G-07L, 188524K-04L, 188524K-06L, 188524L-08L, 188524M-06L, 188524M-07L, 18914.7, 189147D-01, 189147E-01L, 189147F-01L, 189147G-01L, 189147H-01L, 191766A-01, 191766A-02, 191766A-03, 191766A-04, 191766B-01, 191766B-02, 191766B-03, 191766B-04, 191766C-01, 191766C-02, 191766C-03, 191766C-04, 191766D-03L, 191766E-01L, 778757-03, 191766E-02L, 191766E-03L, 778757-04, 191766E-04L, 191766F-01L, 191766F-02L, 191766F-03L, 191766F-04L, 191766G-01L, 191766G-02L, 191766G-03L, 191766G-04L, 191766H-01L, 191766H-02L, 191766H-03L, 191766H-04L, 191766J-01L, 191766J-02L, 191766J-03L, 191766J-04L, 197642A-01, 197642B-01L, 197642C-01L, 197642D-01L, 200151A-01, 778757-01, 778757-02

National Instruments PXI-5124 Frequently Asked Questions

 

Question: Is the PXI-5124 a good device to use for time-domain applications?

Answer: The PXI-5124 is ideal for both time-domain and frequency-domain applications that require high-resolution measurements.

 

Question: What is the maximum bandwidth that the PXI 5124 can process on high-resolution measurements?

Answer: The PXI 5124 can measure up to 150 MHz of analog bandwidth.

 

Question: What are the operating system requirements for the NI PXI-5124?

Answer: The NI PXI-5124 needs Windows 2000/NT/XP to run.

 

Question: Can the amount of memory on the PXI-5124 be visually determined?

Answer: There are two stickers on the back of the PXI-5124, one displaying a barcode and one without. The sticker with no bar code indicates the part number, which can be used to determine the amount of memory.

  PXI-5124 PDF Manuals

  PXI-5124 Diagrams


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PXJ-5124, PXL-5124, PXI-T124, PXI-51Q4, PXI-51E4

PXI-5124



Oscilloscopes > National Instruments > Oscilloscopes

PXI-5124
5/5 | 11 ratings

PXI-5124, 2 Input Channel, 150 MHz, 200 MS/s, Oscilloscope

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXI-5124 Oscilloscope

The National Instruments PXI-5124 (Part Numbers: 778757-01, 778757-02, 778757-03 778757-04, 191766A-02, 191766C-01, and 191766A-01) high-resolution digitizer has various configurations, including: 8 MB/channel Oscilloscope (Part Number: 778757-01), 32 MB/channel Oscilloscope (Part Number: 778757-02), 256 MB/channel Oscilloscope (Part Number: 778757-03), 512 MB/channel Oscilloscope (Part Number: 778757-04).

This oscilloscope highlights two 200 MS/s simultaneous tested data source channels with 2 input channels, 12-bit analog resolution, 150 MHz data transmission, and up to 512 MB of memory for each route in a smaller 3U PXI module. The NI PXI-5124 uses the rapid PCI bus and the scatter-gather bus mastering of the NI MITE ASIC to move information to the PC at speeds up to 100 times speedier than customary instrument interfaces. This helps drastically diminish general test time. With the Synchronization and Memory Core (SMC) design of the PXI-5124, the user can make mixed signal frameworks utilizing signal generators and advanced waveform generator/analyzers or manufacture a high-channel-count digitizer with sub-nanosecond synchronization between channels.

To accomplish inspecting rates different than 200 MS/s when utilizing the inner sample clock, the NI PXI-5124 crushes the examined information. When the user sets an inspecting rate of 50 MS/s, the NI PXI-5124 just stores one out of each four samples it gets from the ADCs to locally available memory. The NI PXI-5124 can test at rates of 200/n MS/s, where n is a whole number an incentive in the vicinity of 1 and 216 – 1. Since this model does not change the recurrence of the clock sent to the ADCs, it makes a sample clock for send out considering the successful examining rate that the user has arranged. The device has a warm-up time of 15 minutes before operation.Also, it has an external calibration interval of 2 years.

The PXI-5124 operates using the NI-SCOPE 2.7 driver software which provides features such as programming interfaces, documentation, and examples for Application Development Environments such as LabVIEW, LabWindows™/CVI™, Measurement Studio, Microsoft Visual C/C++, .NET (C# and VB.NET).The device has 3 BNC female connectors, 2 SMB Jack connectors, and a 9-pin mini-circular DIN connectors.

Apex Waves will continue to Buy, Sell, and Repair EOL NI Hardware in perpetuity. While the PXI-5124 entered the NI Maintenance phase on December 30, 2022, it will remain available with Apex Waves. Request your quote today!

ModelPXI-5124
ManufacturerNational Instruments
Part Numbers778757-01, 778757-02, 778757-03 778757-04, 
191766A-02, 191766C-01, 191766A-01
HTS Code8471804000
TypeOscilloscope
Onboard Memory Size8, 32, 256, or 512 MB/channel
Input Channels2
Analog Input Resolution12 bits
Maximum Bandwidth150 MHz
WarrantyThree Year Warranty
PXI-5124 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXI-5124 Frequently Asked Questions

 

Question: Is the PXI-5124 a good device to use for time-domain applications?

Answer: The PXI-5124 is ideal for both time-domain and frequency-domain applications that require high-resolution measurements.

 

Question: What is the maximum bandwidth that the PXI 5124 can process on high-resolution measurements?

Answer: The PXI 5124 can measure up to 150 MHz of analog bandwidth.

 

Question: What are the operating system requirements for the NI PXI-5124?

Answer: The NI PXI-5124 needs Windows 2000/NT/XP to run.

 

Question: Can the amount of memory on the PXI-5124 be visually determined?

Answer: There are two stickers on the back of the PXI-5124, one displaying a barcode and one without. The sticker with no bar code indicates the part number, which can be used to determine the amount of memory.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn