PXI-6224 National Instruments Multifunction I/O Module | Apex Waves | ImagePXI-6224 National Instruments Multifunction I/O Module | Apex Waves | ImagePXI-6224 NewPXI-6224 | Legacy, Refurbished and New Surplus
PXI-6224 National Instruments Multifunction I/O Module | Apex Waves | Image
PXI-6224 National Instruments Multifunction I/O Module | Apex Waves | Image
PXI-6224 New
PXI-6224 | Legacy, Refurbished and New Surplus

PXI-6224

4.6/5 | 9 ratings

Modular Systems > National Instruments > M Series

Part Number PXI-6224
Manufacturer/Brand National Instruments
Description: PXI-6224, 16 Bit, 250 kS/s, 32 AI, Multifunction I/O Module
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXI-6224 Multifunction I/O Module

The PXI-6224 (Part number: 779114-01) Multifunction I/O Module belongs to the M Series by National Instruments. This module contains DAQ-STC2 and DAQ-6202, which has many important features, including: a PXI interface, PLL for clock synchronization, static DIO signals, true 5 V high current drive DO, digital waveform acquisition and generation, numerous triggering modes, versatile AI and AO sample and convert timing, and more. Along with the other devices in the M Series, the PXI-6224’s analog inputs and outputs have calibration circuitry to fix gain and offset mistakes. The module can be calibrated to reduce AI and AO mistakes from time and temperature drift at run time. External circuitry is not required because an internal reference guarantees the utmost preciseness and steadiness, even during time and temperature alterations.

The National Instruments PXI-6224 has the following specifications: 16 differential or 32 single ended analog input channels, two general-purpose counters/timers, one frequency generator channel, 16 bits resolution, 250 kS/s maximum sample rate, and 50 ns timing resolution.

The front-end signal conditioning system for the PXI-6224 Multifunction I/O Module is SCC, which contains a shielded carrier that can hold as many as 20 single- or dual-channel SCC modules. SCC systems provide the most complete and versatile signal connectivity options. Several of the system features are: a versatile architecture, high bandwidth, easy portability, and small-channel systems. The measurement technology can be selected individually for each channel. A maximum of 16 analog input channels and eight digital I/O lines can be conditioned. Lastly, signals can be obtained at rates as fast as 1.25 MHz. The PXI-6224 is run using the NIDAQmx driver software which is programmed with application development environments (ADEs) such as LabVIEW or LabWindows/CVI. It has a recommended warm-up time of 15 minutes, and should be externally calibrated at least once a year. The standard 3U PXI device weighs 5.9 oz. It has recommended operating and storage temperature ranges of 0 ºC to 55 ºC and -20 ºC to 70 ºC respectively.

PXI-6224 Mature Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

The PXI-6224 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXI-6224 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXI-6224 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXI-6224!

ModelPXI-6224 (779114-01)
ManufacturerNational Instruments
SeriesM Series
TypeMultifunction I/O Module
Analog Input Channels32 single-ended and 16 differential
Sampling Rate250 kS/s
Analog Input Resolution16 bits
WarrantyThree Year Warranty
PXI-6224 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for PXI-6224:

191332A-02, 191332B-02, 191332C-02, 191332D-02, 191332E-02L, 191332F-02L, 191332G-02L, 779114-01

National Instruments PXI-6224 Frequently Asked Questions

 

Question: Does the PXI 6224 have correlated DIO?

 

Answer: Yes, the PXI 6224 has correlated DIO, 32 clocked lines.

 

Question: Can the NI PXI-6224 be used to measure and verify prototype designs?

 

Answer: Yes, the NI PXI-6224 has a wide range of I/O from 80 analog inputs to 48 digital lines, which can be utilized to measure and verify prototype designs.

 

Question: Can sensor and high-voltage measurements be performed with the NI PXI 6224?

 

Answer: Yes, you can add sensor and high-voltage measurements to your NI PXI 6224 with SCC or SCXI signal conditioning modules.  

  PXI-6224 PDF Manuals

  PXI-6224 Diagrams


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PZI-6224, PXK-6224, PXI-U224, PXI-62W4, PXI-622E

PXI-6224



Modular Systems > National Instruments > M Series

PXI-6224
4.6/5 | 9 ratings

PXI-6224, 16 Bit, 250 kS/s, 32 AI, Multifunction I/O Module

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXI-6224 Multifunction I/O Module

The PXI-6224 (Part number: 779114-01) Multifunction I/O Module belongs to the M Series by National Instruments. This module contains DAQ-STC2 and DAQ-6202, which has many important features, including: a PXI interface, PLL for clock synchronization, static DIO signals, true 5 V high current drive DO, digital waveform acquisition and generation, numerous triggering modes, versatile AI and AO sample and convert timing, and more. Along with the other devices in the M Series, the PXI-6224’s analog inputs and outputs have calibration circuitry to fix gain and offset mistakes. The module can be calibrated to reduce AI and AO mistakes from time and temperature drift at run time. External circuitry is not required because an internal reference guarantees the utmost preciseness and steadiness, even during time and temperature alterations.

The National Instruments PXI-6224 has the following specifications: 16 differential or 32 single ended analog input channels, two general-purpose counters/timers, one frequency generator channel, 16 bits resolution, 250 kS/s maximum sample rate, and 50 ns timing resolution.

The front-end signal conditioning system for the PXI-6224 Multifunction I/O Module is SCC, which contains a shielded carrier that can hold as many as 20 single- or dual-channel SCC modules. SCC systems provide the most complete and versatile signal connectivity options. Several of the system features are: a versatile architecture, high bandwidth, easy portability, and small-channel systems. The measurement technology can be selected individually for each channel. A maximum of 16 analog input channels and eight digital I/O lines can be conditioned. Lastly, signals can be obtained at rates as fast as 1.25 MHz. The PXI-6224 is run using the NIDAQmx driver software which is programmed with application development environments (ADEs) such as LabVIEW or LabWindows/CVI. It has a recommended warm-up time of 15 minutes, and should be externally calibrated at least once a year. The standard 3U PXI device weighs 5.9 oz. It has recommended operating and storage temperature ranges of 0 ºC to 55 ºC and -20 ºC to 70 ºC respectively.

PXI-6224 Mature Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

The PXI-6224 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXI-6224 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXI-6224 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXI-6224!

ModelPXI-6224 (779114-01)
ManufacturerNational Instruments
SeriesM Series
TypeMultifunction I/O Module
Analog Input Channels32 single-ended and 16 differential
Sampling Rate250 kS/s
Analog Input Resolution16 bits
WarrantyThree Year Warranty
PXI-6224 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXI-6224 Frequently Asked Questions

 

Question: Does the PXI 6224 have correlated DIO?

 

Answer: Yes, the PXI 6224 has correlated DIO, 32 clocked lines.

 

Question: Can the NI PXI-6224 be used to measure and verify prototype designs?

 

Answer: Yes, the NI PXI-6224 has a wide range of I/O from 80 analog inputs to 48 digital lines, which can be utilized to measure and verify prototype designs.

 

Question: Can sensor and high-voltage measurements be performed with the NI PXI 6224?

 

Answer: Yes, you can add sensor and high-voltage measurements to your NI PXI 6224 with SCC or SCXI signal conditioning modules.  

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn