PXIe-4081 National Instruments PXI Digital Multimeter | Apex Waves | ImagePXIe-4081 National Instruments PXI Digital Multimeter | Apex Waves | ImagePXIe-4081 NewPXIe-4081 | Legacy, Refurbished and New Surplus
PXIe-4081 National Instruments PXI Digital Multimeter | Apex Waves | Image
PXIe-4081 National Instruments PXI Digital Multimeter | Apex Waves | Image
PXIe-4081 New
PXIe-4081 | Legacy, Refurbished and New Surplus

PXIe-4081

4.5/5 | 9 ratings

Modular Systems > National Instruments > PXI Digital Multimeters

Part Number PXIe-4081
Manufacturer/Brand National Instruments
Description: PXIe-4081, 7.5 Digit, 1.8 MS/s, PXI Digital Multimeter
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXIe-4081 PXI Digital Multimeter

The National Instruments PXIe-4081 (Part Number: 783130-01, 154888C-02L) is a 7½-Digit, ±1,000 V; Onboard 1.8 MS/s Isolated Digital Multimeter. The NI PXIe‑4081 is the industry’s most accurate 7½‑digit DMM, which provides the measurement capabilities found in a high-resolution 1,000 V DMM and a digitizer, which are two common test instruments. As a DMM, the PXIe‑4081 delivers speedy, precise AC/DC voltage, AC/DC current, 2‑ or 4‑wire resistance, and frequency/period measurements, as well as diode tests.

In the high-voltage, isolated digitizer mode, the NI PXIe‑4081 can acquire waveforms at sample rates up to 1.8 MS/s at the full input range up to 3 A or 1,000 V. Additionally, the user can choose a PXI DMM that can perform basic inductance and capacitance measurements. For the isolated digitizer, the voltage of the PXIe‑4081 ranges from ±100 mV to ±1000 V (DC or AC coupled), the current ranges from ±1 µA to ±3 A, and the sample rate range is 10 S/s to 1.8 MS/s.

The National Instruments PXIe‑4081 Digital Multimeter has an input impedance of 10 MΩ ± 2% in parallel with 90 pF, and the maximum DC voltage component is 400 V. This DMM has a frequency range from 15 Hz to 500 KHz and a period measurement range from 2 µs to 66.67 ms. This PXI Digital Multimeter has an ADC Linearity range up to 0.5 ppm of reading + 0.5 ppm.

The PXIe‑4081 has a warm-up time of 60 minutes, and should be calibrated once every 2 years. It has an input protection of 1000 VDC or Vpk, and a current mode fuse rating of T 3.5 A 1000 V, time-lag Minimum interrupt rating: 10 kA Siba 5019906.3,5. The NI device is compatible with the NI-DMM driver software and its hardware can be programmed using an application development environment such as LabVIEW or LabWindows/CVI. The device can be configured using the Measurement & Automation Explorer (MAX) tool.

The PXIe-4081 weighs 12 oz., and measures 8.5 x 5.1 x 8.5 in. in physical dimensions. It has a recommended operating temperature range of 0 °C to 55 °C, and a storage temperature range of -40 °C to 71 °C.

The PXIe-4081 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXIe-4081 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXIe-4081 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXIe-4081!

ModelPXIe-4081
Part Number783130-01, 154888C-02L
ManufacturerNational Instruments
TypePXI Digital Multimeter
Digits of Resolution7.5
Maximum Sample Rate1.8 MS/s
Frequency Range15 Hz to 500 kHz
Dimensions8.5 x 5.1 x 8.5 in.
Weight12 oz.
WarrantyThree Year Warranty
PXIe-4081 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the PXIe-4081:

154888A-02L, 154888B-02L, 154888B-22L, 154888C-02L, 155150A-11L, 155150B-11L, 155150C-11L, 155150C-21L, 200099A-01, 200163A-01, 200176A-01, 200276A-01, 200416A-01, 783130-01, 784489-01, 788553-01

National Instruments PXIe-4081 Frequently Asked Questions

 

Question: What is the basic DC voltage accuracy for the PXIe-4081?

 

Answer: The basic DC voltage accuracy for the PXIe-4081 is 12 ppm.

 

Question: What is the DC voltage range for the NI PXIe-4081?

 

Answer: The DC voltage range for the NI PXIe-4081 is -1000 V to 1000 V.

 

Question: Can the PXIe-4081 perform L&C measurements?

 

Answer: No, the PXIe-4081 cannot perform L&C measurements.

 

Question: Which functions are available on the isolated digitizer on the PXIe-4081?

 

Answer: The isolated digitizer on the PXIe-4081 has voltage and current functions.

  PXIe-4081 PDF Manuals

Driver Downloads for PXIe-4081






OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: LXIE-4081, PXIW-4081, PXID-4081, PXIF-4081, PXIE-408Q

PXIe-4081



Modular Systems > National Instruments > PXI Digital Multimeters

PXIe-4081
4.5/5 | 9 ratings

PXIe-4081, 7.5 Digit, 1.8 MS/s, PXI Digital Multimeter

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXIe-4081 PXI Digital Multimeter

The National Instruments PXIe-4081 (Part Number: 783130-01, 154888C-02L) is a 7½-Digit, ±1,000 V; Onboard 1.8 MS/s Isolated Digital Multimeter. The NI PXIe‑4081 is the industry’s most accurate 7½‑digit DMM, which provides the measurement capabilities found in a high-resolution 1,000 V DMM and a digitizer, which are two common test instruments. As a DMM, the PXIe‑4081 delivers speedy, precise AC/DC voltage, AC/DC current, 2‑ or 4‑wire resistance, and frequency/period measurements, as well as diode tests.

In the high-voltage, isolated digitizer mode, the NI PXIe‑4081 can acquire waveforms at sample rates up to 1.8 MS/s at the full input range up to 3 A or 1,000 V. Additionally, the user can choose a PXI DMM that can perform basic inductance and capacitance measurements. For the isolated digitizer, the voltage of the PXIe‑4081 ranges from ±100 mV to ±1000 V (DC or AC coupled), the current ranges from ±1 µA to ±3 A, and the sample rate range is 10 S/s to 1.8 MS/s.

The National Instruments PXIe‑4081 Digital Multimeter has an input impedance of 10 MΩ ± 2% in parallel with 90 pF, and the maximum DC voltage component is 400 V. This DMM has a frequency range from 15 Hz to 500 KHz and a period measurement range from 2 µs to 66.67 ms. This PXI Digital Multimeter has an ADC Linearity range up to 0.5 ppm of reading + 0.5 ppm.

The PXIe‑4081 has a warm-up time of 60 minutes, and should be calibrated once every 2 years. It has an input protection of 1000 VDC or Vpk, and a current mode fuse rating of T 3.5 A 1000 V, time-lag Minimum interrupt rating: 10 kA Siba 5019906.3,5. The NI device is compatible with the NI-DMM driver software and its hardware can be programmed using an application development environment such as LabVIEW or LabWindows/CVI. The device can be configured using the Measurement & Automation Explorer (MAX) tool.

The PXIe-4081 weighs 12 oz., and measures 8.5 x 5.1 x 8.5 in. in physical dimensions. It has a recommended operating temperature range of 0 °C to 55 °C, and a storage temperature range of -40 °C to 71 °C.

The PXIe-4081 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXIe-4081 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXIe-4081 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXIe-4081!

ModelPXIe-4081
Part Number783130-01, 154888C-02L
ManufacturerNational Instruments
TypePXI Digital Multimeter
Digits of Resolution7.5
Maximum Sample Rate1.8 MS/s
Frequency Range15 Hz to 500 kHz
Dimensions8.5 x 5.1 x 8.5 in.
Weight12 oz.
WarrantyThree Year Warranty
PXIe-4081 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXIe-4081 Frequently Asked Questions

 

Question: What is the basic DC voltage accuracy for the PXIe-4081?

 

Answer: The basic DC voltage accuracy for the PXIe-4081 is 12 ppm.

 

Question: What is the DC voltage range for the NI PXIe-4081?

 

Answer: The DC voltage range for the NI PXIe-4081 is -1000 V to 1000 V.

 

Question: Can the PXIe-4081 perform L&C measurements?

 

Answer: No, the PXIe-4081 cannot perform L&C measurements.

 

Question: Which functions are available on the isolated digitizer on the PXIe-4081?

 

Answer: The isolated digitizer on the PXIe-4081 has voltage and current functions.

Software & Drivers





OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit

 Download Version

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn