Part Number PXIe-4353
Manufacturer/Brand National Instruments
Description: PXIe-4353, 32-Channel, Temperature Input Module
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXIe-4353 PXI Temperature Input Module

The PXIe-4353 (Part Number: 781348-01) is a 32 thermocouple analog input channel (differential) Temperature Input Module from NI. It has an analog input isolation of 300 V. This module also incorporates 2 auto zero and 8 cold junction compensation channels. This module accomplished temperature measurements with high accuracy. The NI PXIe-4353 Temperature Input Module has a built-in TB-4353 isothermal terminal block for maximum conductivity to achieve high performance. It is located between the terminals of thermocouple and CJC channels. The sampling mode that is implemented by the device is scanned. It also incorporates an analog to digital converter, which is the Delta-Sigma type. The maximum sample rate offered by the PXIe-4353 module is 90 S/s.

The NI PXIe 4353 has the voltage measurement range of ±80 mV. The value for the differential input impedance of the instrument is 20 mega-ohms. The typical value for DC linearity is 20 ppm. It has the maximum value of 60 ppm. The instrument implements an open thermal couple detection feature for measurements, which is software selectable. The user can select it for each module. The input current in OTD enabled mode is 17 Nano-amperes, while the value in OTD disabled mode is 400 Pico-amperes. The National Instruments PXIe-4353 Temperature Input Module offers a full NIST temperature range.

The PXIe-4353 is run using the NI-DAQmx driver software which is compatible with software packages/application development environments such as LabVIEW, LabWindows/CVI, or Measurement Studio.

The NI PXIe-4353 module has the channel to channel voltage range of ± 10 volts for the common mode of operation. The voltage range of the instrument for the channel to earth ground is ± 300 volts. The channel to common mode rejection ratio is 100 dB. The instrument also incorporates an overvoltage protection feature.

The NI device weighs 4.9 oz, and measures 6.3 x 3.9 in. in physical dimensions. It has a recommended operating temperature range of 0 °C to 55 °C, and a storage temperature range of -40 °C to 71 °C. The NI device has a recommended warm-up time of 15 minutes, and should be calibrated at least once a year.

The PXIe-4353 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXIe-4353 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXIe-4353 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXIe-4353!

ModelPXIe-4353
Part Number781348-01
ManufacturerNational Instruments
TypePXI Temperature Input Module
Differential Analog Input Channels32
Supported Sensor TypeThermocouple
Analog Input Isolation300 V Bank Isolation
Dimensions6.3 x 3.9 in.
Weight4.9 oz.
WarrantyThree Year Warranty
PXIe-4353 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the PXIe-4353:

151912A-01L, 194969A-01L, 194969B-01L, 194969C-01L, 194969E-01L, 194969F-01L, 200164A-01, 200167A-01, 781348-01

National Instruments PXIe-4353 Frequently Asked Questions

 

Question: How long is the PXIe-4353 calibration interval?

 

Answer: The PXIe-4353 calibration interval is one year.

 

Question: What are the power requirements for the NI PXIe-4353?

 

Answer: The NI PXIe-4353 requires 570 mA at +3.3 V and 200 mA at +12 V.

 

Question: What are temperature measurement errors based on for the PXIe-4353?

 

Answer: For the PXIe-4353, temperature measurement errors are based on the preciseness of the measurement module, the cold-junction temperature, the thermocouple type, the temperature being measured, and the preciseness of the thermocouple wire.

 

Question: Can the NI PXIe-4353 be calibrated without the use of CAL-4353 and Fluke 5520A?

 

Answer: CAL-4353 and Fluke 5520A are recommended accessories to calibrate the NI PXIe-4353 externally, therefore an internal calibration can be performed without the additional accessories.

  PXIe-4353 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: OXIE-4353, PXJE-4353, PXKE-4353, PXOE-4353, PXIE-T353

PXIe-4353



Modular Systems > National Instruments > SC Express Series

PXIe-4353
4.5/5 | 13 ratings

PXIe-4353, 32-Channel, Temperature Input Module

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXIe-4353 PXI Temperature Input Module

The PXIe-4353 (Part Number: 781348-01) is a 32 thermocouple analog input channel (differential) Temperature Input Module from NI. It has an analog input isolation of 300 V. This module also incorporates 2 auto zero and 8 cold junction compensation channels. This module accomplished temperature measurements with high accuracy. The NI PXIe-4353 Temperature Input Module has a built-in TB-4353 isothermal terminal block for maximum conductivity to achieve high performance. It is located between the terminals of thermocouple and CJC channels. The sampling mode that is implemented by the device is scanned. It also incorporates an analog to digital converter, which is the Delta-Sigma type. The maximum sample rate offered by the PXIe-4353 module is 90 S/s.

The NI PXIe 4353 has the voltage measurement range of ±80 mV. The value for the differential input impedance of the instrument is 20 mega-ohms. The typical value for DC linearity is 20 ppm. It has the maximum value of 60 ppm. The instrument implements an open thermal couple detection feature for measurements, which is software selectable. The user can select it for each module. The input current in OTD enabled mode is 17 Nano-amperes, while the value in OTD disabled mode is 400 Pico-amperes. The National Instruments PXIe-4353 Temperature Input Module offers a full NIST temperature range.

The PXIe-4353 is run using the NI-DAQmx driver software which is compatible with software packages/application development environments such as LabVIEW, LabWindows/CVI, or Measurement Studio.

The NI PXIe-4353 module has the channel to channel voltage range of ± 10 volts for the common mode of operation. The voltage range of the instrument for the channel to earth ground is ± 300 volts. The channel to common mode rejection ratio is 100 dB. The instrument also incorporates an overvoltage protection feature.

The NI device weighs 4.9 oz, and measures 6.3 x 3.9 in. in physical dimensions. It has a recommended operating temperature range of 0 °C to 55 °C, and a storage temperature range of -40 °C to 71 °C. The NI device has a recommended warm-up time of 15 minutes, and should be calibrated at least once a year.

The PXIe-4353 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXIe-4353 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXIe-4353 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXIe-4353!

ModelPXIe-4353
Part Number781348-01
ManufacturerNational Instruments
TypePXI Temperature Input Module
Differential Analog Input Channels32
Supported Sensor TypeThermocouple
Analog Input Isolation300 V Bank Isolation
Dimensions6.3 x 3.9 in.
Weight4.9 oz.
WarrantyThree Year Warranty
PXIe-4353 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXIe-4353 Frequently Asked Questions

 

Question: How long is the PXIe-4353 calibration interval?

 

Answer: The PXIe-4353 calibration interval is one year.

 

Question: What are the power requirements for the NI PXIe-4353?

 

Answer: The NI PXIe-4353 requires 570 mA at +3.3 V and 200 mA at +12 V.

 

Question: What are temperature measurement errors based on for the PXIe-4353?

 

Answer: For the PXIe-4353, temperature measurement errors are based on the preciseness of the measurement module, the cold-junction temperature, the thermocouple type, the temperature being measured, and the preciseness of the thermocouple wire.

 

Question: Can the NI PXIe-4353 be calibrated without the use of CAL-4353 and Fluke 5520A?

 

Answer: CAL-4353 and Fluke 5520A are recommended accessories to calibrate the NI PXIe-4353 externally, therefore an internal calibration can be performed without the additional accessories.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn