PXIe-5632
Modular Systems > National Instruments > PXI Analyzers
Description: | PXIe-5632, 2-Port, 8.5 GHz, PXI Vector Network Analyzer |
Need an Official Quote?
Or speak to a sales representative for additional information:
National Instruments PXIe-5632 PXI Vector Network Analyzer
With full vector analysis, automatic precision, reference plane extensions, and full vector analysis features, the National Instruments PXIe-5632 (Part Numbers: 782299-01 and 782299-02) Vector Network Analyzer is an ideal testing instrument for users’ validation and production operations. The NI PXIe-5632 VNA operates on a frequency range from 300 KHz to 8.5 GHz and has independent frequency bandwidths from 10 Hz to 500 KHz. These specifications allow the users to balance measurement speed and accuracy within their applications. The source access loops and low latency trigger allows users to achieve pulsed s-parameter measurements, including measurements requiring an extended power range. Part number 782299-02 features Time Domain Analysis capabilities.
The PXIe-5632 VNA facilitates seamless incorporation into test systems that combine a range of RF and mixed signal I/O devices without increasing the test equipment footprint. With the flexible APIs for both NI LabVIEW and LabWindows/CVI software, users can quickly perform automated tests or use the full options featured on the soft front panel to perform user calibration and make measurements right out of the box.
The PXIe 5632 accepts a power range from +15 dBm to -30 dBm, 0.01 dB steps, and a dynamic range > 110 dB (typical) below 8 GHz. The powerful architectural design features dedicated ADCs, low latency triggers, power level control, dual sources, and source loops. The measurement time for this instrument is <65 µsec/pt (100 kHz IFBW) with 20,001 points. The PXIe-5632 VNA dimensions are 8.5 in. × 2.4 in. × 5.1 in. and the model weighs 45.0 oz.
Model | PXIe-5632 |
---|---|
Part Numbers | 782299-01 and 782299-02 |
Manufacturer | National Instruments |
Type | PXI Vector Network Analyzer |
Sources Supported | 2 |
Maximum Source Power | 15 dBm |
Frequency Range | 300 kHz to 8.5 GHz |
Dimensions | 8.5 x 2.4 x 5.1 in. |
Weight | 45.0 oz. |
Warranty | 2-3 Year Warranty |
PXIe-5632 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for PXIe-5632:
154013A-01L, 154013A-02L, 200308A-01, 782299-01, 782299-02
National Instruments PXIe-5632 Frequently Asked Questions
Question: Which instrument driver should be used with the NI PXIe-5632 VNA?
Answer: The NI PXIe-5632 VNA can be used with the NI-VNA instrument driver.
Question: What is the difference between the part numbers of the PXIe-5632?
Answer: Part number 782299-01 is the standard version of the PXIe-5632, while part number 782299-02 features time domain analysis.
Question: Which S parameter measurements does the NI PXIe-5632 support?
Answer: The NI PXIe-5632 supports all S-parameter measurements.
Question: What are the power requirements for the PXIe-5632?
Answer: The PXIe-5632 requires 6.2 A typical at 3.3 VDC and 3.3 A typical at 12 VDC.
Question: How long is the calibration interval for the NI PXIe-5632?
Answer: The NI PXIe-5632 should be calibrated every year.
Part Number | Additional Attributes |
782299-01 | |
782299-02 | Time Domain Analysis |
PXIe-5632 PDF Manuals
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI PXIE 5632 GETTING STARTED GUIDE.PDF
PXIE 5632 CALIBRATION PROCEDURE.PDF
PXIE 5632 LETTER OF VOLATILITY.PDF
TIME DOMAIN ANALYSIS FOR NI VECTOR NETWORK ANALYZERS ACTIVATION INSTRUCTIONS.PDF
Driver Downloads for PXIe-5632
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-5632
Modular Systems > National Instruments > PXI Analyzers
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Part Variations
- Manuals & PDFs
- Drivers
National Instruments PXIe-5632 PXI Vector Network Analyzer
With full vector analysis, automatic precision, reference plane extensions, and full vector analysis features, the National Instruments PXIe-5632 (Part Numbers: 782299-01 and 782299-02) Vector Network Analyzer is an ideal testing instrument for users’ validation and production operations. The NI PXIe-5632 VNA operates on a frequency range from 300 KHz to 8.5 GHz and has independent frequency bandwidths from 10 Hz to 500 KHz. These specifications allow the users to balance measurement speed and accuracy within their applications. The source access loops and low latency trigger allows users to achieve pulsed s-parameter measurements, including measurements requiring an extended power range. Part number 782299-02 features Time Domain Analysis capabilities.
The PXIe-5632 VNA facilitates seamless incorporation into test systems that combine a range of RF and mixed signal I/O devices without increasing the test equipment footprint. With the flexible APIs for both NI LabVIEW and LabWindows/CVI software, users can quickly perform automated tests or use the full options featured on the soft front panel to perform user calibration and make measurements right out of the box.
The PXIe 5632 accepts a power range from +15 dBm to -30 dBm, 0.01 dB steps, and a dynamic range > 110 dB (typical) below 8 GHz. The powerful architectural design features dedicated ADCs, low latency triggers, power level control, dual sources, and source loops. The measurement time for this instrument is <65 µsec/pt (100 kHz IFBW) with 20,001 points. The PXIe-5632 VNA dimensions are 8.5 in. × 2.4 in. × 5.1 in. and the model weighs 45.0 oz.
Model | PXIe-5632 |
---|---|
Part Numbers | 782299-01 and 782299-02 |
Manufacturer | National Instruments |
Type | PXI Vector Network Analyzer |
Sources Supported | 2 |
Maximum Source Power | 15 dBm |
Frequency Range | 300 kHz to 8.5 GHz |
Dimensions | 8.5 x 2.4 x 5.1 in. |
Weight | 45.0 oz. |
Warranty | 2-3 Year Warranty |
PXIe-5632 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXIe-5632 Frequently Asked Questions
Question: Which instrument driver should be used with the NI PXIe-5632 VNA?
Answer: The NI PXIe-5632 VNA can be used with the NI-VNA instrument driver.
Question: What is the difference between the part numbers of the PXIe-5632?
Answer: Part number 782299-01 is the standard version of the PXIe-5632, while part number 782299-02 features time domain analysis.
Question: Which S parameter measurements does the NI PXIe-5632 support?
Answer: The NI PXIe-5632 supports all S-parameter measurements.
Question: What are the power requirements for the PXIe-5632?
Answer: The PXIe-5632 requires 6.2 A typical at 3.3 VDC and 3.3 A typical at 12 VDC.
Question: How long is the calibration interval for the NI PXIe-5632?
Answer: The NI PXIe-5632 should be calibrated every year.
Part Number | Additional Attributes |
782299-01 | |
782299-02 | Time Domain Analysis |
PXIe-5632 PDF Manuals & Diagrams
PXIe-5632 PDF Manuals
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI PXIE 5632 GETTING STARTED GUIDE.PDF
PXIE 5632 CALIBRATION PROCEDURE.PDF
PXIE 5632 LETTER OF VOLATILITY.PDF
TIME DOMAIN ANALYSIS FOR NI VECTOR NETWORK ANALYZERS ACTIVATION INSTRUCTIONS.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."