SCC-FT01 National Instruments Feedthrough Module | Apex Waves | ImageSCC-FT01 National Instruments Feedthrough Module | Apex Waves | ImageSCC-FT01 NewSCC-FT01 | Legacy, Refurbished and New Surplus
SCC-FT01 National Instruments Feedthrough Module | Apex Waves | Image
SCC-FT01 National Instruments Feedthrough Module | Apex Waves | Image
SCC-FT01 New
SCC-FT01 | Legacy, Refurbished and New Surplus

SCC-FT01

4.8/5 | 10 ratings

Modular Systems > National Instruments > SCC

Part Number SCC-FT01
Manufacturer/Brand National Instruments
Description: SCC-FT01, 2 SE/1 DI Channels, Feedthrough Module
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments SCC-FT01 Feedthrough Module

The National Instruments SCC-FT01 (Part Number: 777459-01) is a Feedthrough Module that interfaces straightforwardly to the analog input (AI) and analog output (AO) channels of a data acquisition (DAQ) device in the E Series. The breadboard region of the NI SCC-FT01 can be used to create unique signal molding hardware that can associate with and condition any of the analog, digital (P0.), and general-purpose counter/clock (CTR) channels of the E Series DAQ gadgets. To utilize the SCC-FT01 Feedthrough Module for CTR capacities, the user can utilize the pads above connector J2 labeled CTR for associations with the breadboard region. A NI SCC-FT01 signal association label, which defines the pad numbers on the SCC-FT01 Feedthrough Module, is connected to the inside of the enclosure of the SCC module. Regardless of whether the user connects the NI SCC-FT01 to a SCC attachment for AI, AO, computerized, or counter molding, the pads recorded under the “all” segment are associated and can be employed. The device has 2 single-ended or 1 differential analog input channel, and 1 analog output channel when plugged into an AO socket on the SC-2345. It is equipped with a 20-pin right-angle male connector and a 6-pin screw terminal system–with the screw terminal having a dimension of 28 to 16 AWG.

The user has the option to link the SCC-FT01 to the CTR CH0 attachment J19. In addition, when the National Instruments SCC-FT01 Feedthrough Module is connected to the CTR CH1 attachment J20, the pads under CTR CH1 on the board connect with signals related with CTR channel 1 and AI of the E Series DAQ gadget. The user can also access cascading signals from nearby SCC modules.

The SCC-FT01 is run using the NI-DAQmx, traditional NI-DAQ, NI-VISA driver software which are compatible with software packages/application development environments (ADEs) such as LabVIEW, LabVIEW Real-Time module, LabWindows/CVI, Visual C++, Visual Basic, or Measurement Studio. The device hardware can be configured using the Measurement & Automation Explorer (MAX) tool. The NI device measures 3.5 x 1.15 x 0.73 in. in physical dimensions.

SCC-FT01 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

ModelSCC-FT01, 777459-01
ManufacturerNational Instruments
SeriesSCC
TypeFeedthrough Module
Channels2 SE/1 DI
Accessible Power5 and ±15 VDC
Dimensions3.5 x 1.2 x 0.7 in.
WarrantyThree Year Warranty
SCC-FT01 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCC-FT01 Frequently Asked Questions

 

Question: What is the maximum amplitude of input voltage for the NI SCC-FT01?

 

Answer: The maximum amplitude of input voltage that the NI SCC-FT01 can use is dependent on the DAQ board.

 

Question: Can you use the SCC-FT01 to develop custom circuitry?

 

Answer: Yes, you can use the breadboard area of the SCC-FT01 to develop custom signal-conditioning circuitry, allowing you to connect to analog, digital, and general-purpose counter/timer channels of E Series DAQ devices.

 

Question: Can you plug the National Instruments SCC-FT01 into the SC-2345?

 

Answer: Yes, you can plug the National Instruments SCC-FT01 into an AI or AO socket on the SC-2345.

  SCC-FT01 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: QCC-FT01, WCC-FT01, CCC-FT01, SCC-RT01, SCC-FTO1

SCC-FT01



Modular Systems > National Instruments > SCC

SCC-FT01
4.8/5 | 10 ratings

SCC-FT01, 2 SE/1 DI Channels, Feedthrough Module

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments SCC-FT01 Feedthrough Module

The National Instruments SCC-FT01 (Part Number: 777459-01) is a Feedthrough Module that interfaces straightforwardly to the analog input (AI) and analog output (AO) channels of a data acquisition (DAQ) device in the E Series. The breadboard region of the NI SCC-FT01 can be used to create unique signal molding hardware that can associate with and condition any of the analog, digital (P0.), and general-purpose counter/clock (CTR) channels of the E Series DAQ gadgets. To utilize the SCC-FT01 Feedthrough Module for CTR capacities, the user can utilize the pads above connector J2 labeled CTR for associations with the breadboard region. A NI SCC-FT01 signal association label, which defines the pad numbers on the SCC-FT01 Feedthrough Module, is connected to the inside of the enclosure of the SCC module. Regardless of whether the user connects the NI SCC-FT01 to a SCC attachment for AI, AO, computerized, or counter molding, the pads recorded under the “all” segment are associated and can be employed. The device has 2 single-ended or 1 differential analog input channel, and 1 analog output channel when plugged into an AO socket on the SC-2345. It is equipped with a 20-pin right-angle male connector and a 6-pin screw terminal system–with the screw terminal having a dimension of 28 to 16 AWG.

The user has the option to link the SCC-FT01 to the CTR CH0 attachment J19. In addition, when the National Instruments SCC-FT01 Feedthrough Module is connected to the CTR CH1 attachment J20, the pads under CTR CH1 on the board connect with signals related with CTR channel 1 and AI of the E Series DAQ gadget. The user can also access cascading signals from nearby SCC modules.

The SCC-FT01 is run using the NI-DAQmx, traditional NI-DAQ, NI-VISA driver software which are compatible with software packages/application development environments (ADEs) such as LabVIEW, LabVIEW Real-Time module, LabWindows/CVI, Visual C++, Visual Basic, or Measurement Studio. The device hardware can be configured using the Measurement & Automation Explorer (MAX) tool. The NI device measures 3.5 x 1.15 x 0.73 in. in physical dimensions.

SCC-FT01 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. 

ModelSCC-FT01, 777459-01
ManufacturerNational Instruments
SeriesSCC
TypeFeedthrough Module
Channels2 SE/1 DI
Accessible Power5 and ±15 VDC
Dimensions3.5 x 1.2 x 0.7 in.
WarrantyThree Year Warranty
SCC-FT01 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments SCC-FT01 Frequently Asked Questions

 

Question: What is the maximum amplitude of input voltage for the NI SCC-FT01?

 

Answer: The maximum amplitude of input voltage that the NI SCC-FT01 can use is dependent on the DAQ board.

 

Question: Can you use the SCC-FT01 to develop custom circuitry?

 

Answer: Yes, you can use the breadboard area of the SCC-FT01 to develop custom signal-conditioning circuitry, allowing you to connect to analog, digital, and general-purpose counter/timer channels of E Series DAQ devices.

 

Question: Can you plug the National Instruments SCC-FT01 into the SC-2345?

 

Answer: Yes, you can plug the National Instruments SCC-FT01 into an AI or AO socket on the SC-2345.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn