National Instruments SCXI:Part 8

This is part 8 in our ongoing blog series about the National Instruments SCXI platform. Part 8 will describe the rack-mountable SCXI Terminal Blocks. If you missed the previous blog posts, you can view them on our blog!

 

The BNC-2095 and TC-2095 shielded, rack-mountable terminal accessories for SCXI have BNC and thermocouple connectors, respectively. The BNC-2095 and TC-2095 cable to the SCXI-1100SCXI-1102, and SCXI-1102B/CSCX-1104 32-channel input modules. You cable the BNC-2095 and TC-2095 to the front connector of the SCXI module with the SH96-96 shielded cable or R96-96 ribbon cable.

 

 

The TBX-1303, created for thermocouples, is additionally effective for general-purpose applications. This terminal block has special features for thermocouples, such as isothermal construction with a plastic cover to reduce thermal gradients, open-thermocouple detection circuitry, and automatic ground referencing circuitry. When utilizing the TBX-1303 with the SCXI-1102 Series, this terminal block delivers a high-impedance path to ground, so that systems work dependably with floating or ground-referenced thermocouples. For applications with the SCXI-1100, you can configure the channels to be ground-referenced or floating in blocks of eight channels. For general purpose applications, this terminal block is equipped with 108 terminals, including CH+, CH-, and shield for every input channel. The TBX-1303 works with the SCXI-1181 breadboard module as well.

 

 

The National Instruments TBX-1316 is a high voltage attenuator terminal block created to be used with the SCXI-1125SCXI-1120/D, and SCXI-1126 analog input modules. The NI TBX-1316 extends the input voltage range for AC/DC signals to 1,000 V for Category I installations and 600 V for Category II installations. For voltage measurements, the TBX-1316 is suggested for use with the SCXI-1125 but can be used with the SCXI-1120/D also. For frequency measurements, utilize the TBX-1316 with the SCXI-1126.

 

The TBX-1325 has 30 screw terminals for signal connections to the SCXI-1124 module. You cable the TBX-1325 to the SCXI module with the SH48-48-A shielded cable. However, keep in mind that the TBX-1325 and SH48-48-A limit the maximum working common-mode voltage between banks or between banks and earth ground to 250 Vrms maximum.

 

The TBX-1326 is a high-voltage terminal block with 48 screw terminals for signal connections to the SCXI-1162SCXI-1162HVSCXI-1163, and SCXI-1163R modules. You cable the TBX-1326 to the SCXI module with the SH48-48-B shielded cable.

 

The TBX-1328 can be used in conjunction with the SCXI-1120SCXI-1120DSCXI-1121SCXI-1125, and SCXI-1126 modules. The TBX-1328 has 24 screw terminals, including three terminals (CH+, CH-, and chassis ground) for every input channel and sockets for the installation of resistors for 4-20 mA inputs. When used with thermocouples, the TBX-1328 optimizes measurement preciseness with an isothermal construction and a plastic cover that decreases thermal gradients across the terminal block and the subsequent errors.

 

The TBX-1329 delivers selectable AC coupling for the SCXI-1120SCXI-1120DSCXI-1121SCXI-1125, and SCXI-1126 modules. Every channel of the TBX-1329 terminal block includes selectable AC coupling circuitry that can reject up to 250 VDC. The screw terminals on the TBX-1329 are pluggable.

 

The NI TBX-24F general-purpose screw terminal block has feed-through connections for 24 signal lines. The TBX-24F can be linked to the SCXI module with discrete wires connected to a regular SCXI terminal block. For example, you can utilize two TBX-24F blocks to terminate the I/O lines for one SCXI-1160 relay module, which needs 48 signal connections (16 relays, 3 lines per relay). You separately wire the TBX-24F to a regular SCXI-1324 terminal block, which attaches to the front of the SCXI-1160 module.

 

Lastly, the National Instruments BNC-2096 is a 19 in. rack-mountable BNC terminal block for NI PXI-447xPXI-4461, and SCXI-153x modules. It provides 16 channels of Class I smart TEDS sensor inputs for IEPE sensors such as microphones and accelerometers. The NI BNC-2096 requires digital control from a NI 4021 switch controller or data acquisition device. Two or more BNC-2096 blocks can be controlled by a single device, enabling multidrop configurations for high-channel-count systems.

Sign Up for Our Newsletter!

    A monthly email packed with valuable content—industry news, tutorials, obsolescence updates, and more. No sales pitches, just insights we think you'll find helpful!

    Posts You May Like
    Setup and Optimize the National Instruments PXI-5441 Waveform Generator

    The National Instruments PXI-5441 is a powerful PXI waveform generator designed to support high-speed waveform downloads up...

    October 25, 2024
    How NVIDIA Jetson Systems are Revolutionizing AI Applications

    Companies in almost every industry are being transformed by artificial intelligence, and autonomous machines are...

    March 2, 2023
    How to Use a NI Spectrum Analyzer with an RF Signal Generator

    The PXIe Platform from National Instruments offers an incredibly valuable toolset for test and measurement innovation. Its...

    October 16, 2024
    Simulating Circuits With SPICE

    It is no secret that simulation and testing is an important part of designing circuits....

    February 16, 2023