Modular Systems > National Instruments > FieldDAQ




Or speak to a sales representative for additional information:
786374-01 Request for Availablility
786374-01, 8 Input Channels, 24 Bits, ±10.5 V, FD-11601 Voltage Input Device for FieldDAQ
Need an Official Quote?
National Instruments 786374-01 Voltage Input Device for FieldDAQ.
Part Number 786374-01 is the identifying part number for the National Instruments FD-11601 Voltage Input Device for FieldDAQ. The 786374-01 has 8 analog input channels with galvanic isolation between the channels and the chassis. Likewise, the device has a Delta-sigma ADC with a resolution of 24 bits and analog prefiltering. Similarly, the voltage range in the input channels is ±10.5 V. The timebase frequency can be set to 13.1072 MHz, 12.8 MHz, 12.288 MHz, and 10.24 MHz with an accuracy of ±30 ppm maximum. The sample rate may range from a
minimum of 500 samples/s to a maximum of 102.4 kSamples/s.
The 786374-01 supports both the TCP/IP and UDP protocols and uses various network ports: HTTP:80 (configuration only), TCP:3580; UDP:5353 (configuration only), TCP:5353 (configuration only); TCP:31415; UDP:7865 (configuration only), UDP:8473 (configuration only). The default MTU size is 1500 bytes. On the other hand, it has two internally-switched 8-pin X-coded M12 ports for Ethernet/ The communication rates are negotiated between 10/100/1000 Mbps depending on the interface. The maximum cabling distance is 100 m per segment and the maximum hops per line is 15.
The 786374-01 supports an input voltage range of 9 VDC to 30 VDC while the maximum device power consumption can reach 16 W. A 5-pin L-coded male M12 is used for both power input and power output. Note that the torque for M12 connectors should be 0.6 Nm. The maximum current in the Power IN/OUT terminals is 10 A and a 16 A, slow blow fuse is recommended for external overcurrent protection.
The 786374-01 measures (7.8 in. × 3.0 in. × 1.9 in.) in physical dimensions and weighs 1.2 kg. Likewise, it has a calibration interval of 1 year. The device is recommended for operation between -40 °C to 85 °C at a relative humidity of up to 100%. On the other hand, it can be stored between -40 °C to 100 °C. Note that the device should be operated within a maximum altitude of 5000 m.
Part Number | 786374-01 |
---|---|
Model Name | FD-11601 |
Part Type | Voltage Input Device for FieldDAQ |
Number of Analog Input Channels | 8 |
ADC Resolution | 24 bits |
Analog Input Voltage Range | ±10.5 V |
Timebase Frequency | 13.1072 MHz, 12.8 MHz, 12.288 MHz, and 10.24 MHz |
Sample Rate | 500 samples/s to 102.4 kSamples/s |
Maximum Device Power Consumption | 16.0 W |
Device Input Voltage Range | 9 VDC to 30 VDC |
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
786374-01
Modular Systems > National Instruments > FieldDAQ
786374-01, 8 Input Channels, 24 Bits, ±10.5 V, FD-11601 Voltage Input Device for FieldDAQ
1-800-915-6216
- Description
- Technical Specifications
- Manuals & PDFs
National Instruments 786374-01 Voltage Input Device for FieldDAQ.
Part Number 786374-01 is the identifying part number for the National Instruments FD-11601 Voltage Input Device for FieldDAQ. The 786374-01 has 8 analog input channels with galvanic isolation between the channels and the chassis. Likewise, the device has a Delta-sigma ADC with a resolution of 24 bits and analog prefiltering. Similarly, the voltage range in the input channels is ±10.5 V. The timebase frequency can be set to 13.1072 MHz, 12.8 MHz, 12.288 MHz, and 10.24 MHz with an accuracy of ±30 ppm maximum. The sample rate may range from a
minimum of 500 samples/s to a maximum of 102.4 kSamples/s.
The 786374-01 supports both the TCP/IP and UDP protocols and uses various network ports: HTTP:80 (configuration only), TCP:3580; UDP:5353 (configuration only), TCP:5353 (configuration only); TCP:31415; UDP:7865 (configuration only), UDP:8473 (configuration only). The default MTU size is 1500 bytes. On the other hand, it has two internally-switched 8-pin X-coded M12 ports for Ethernet/ The communication rates are negotiated between 10/100/1000 Mbps depending on the interface. The maximum cabling distance is 100 m per segment and the maximum hops per line is 15.
The 786374-01 supports an input voltage range of 9 VDC to 30 VDC while the maximum device power consumption can reach 16 W. A 5-pin L-coded male M12 is used for both power input and power output. Note that the torque for M12 connectors should be 0.6 Nm. The maximum current in the Power IN/OUT terminals is 10 A and a 16 A, slow blow fuse is recommended for external overcurrent protection.
The 786374-01 measures (7.8 in. × 3.0 in. × 1.9 in.) in physical dimensions and weighs 1.2 kg. Likewise, it has a calibration interval of 1 year. The device is recommended for operation between -40 °C to 85 °C at a relative humidity of up to 100%. On the other hand, it can be stored between -40 °C to 100 °C. Note that the device should be operated within a maximum altitude of 5000 m.
Part Number | 786374-01 |
---|---|
Model Name | FD-11601 |
Part Type | Voltage Input Device for FieldDAQ |
Number of Analog Input Channels | 8 |
ADC Resolution | 24 bits |
Analog Input Voltage Range | ±10.5 V |
Timebase Frequency | 13.1072 MHz, 12.8 MHz, 12.288 MHz, and 10.24 MHz |
Sample Rate | 500 samples/s to 102.4 kSamples/s |
Maximum Device Power Consumption | 16.0 W |
Device Input Voltage Range | 9 VDC to 30 VDC |
786374-01 PDF Manuals & Diagrams
786374-01 PDF Manuals
FD 11601 SAFETY ENVIRONMENTAL AND REGULATORY INFORMATION.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."