Modular Systems > National Instruments > Accessories




Or speak to a sales representative for additional information:
783198-01 Request for Availablility
783198-01, 35 mm DIN Rail, DIN Rail Kit for the NI SCB-68 HSDIO
Need an Official Quote?
National Instruments 783198-01 DIN Rail Kit For SCB-68-HSDIO
Part Number 783198-01 is the identifying part number for the DIN Rail Kit for the National Instruments SCB-68-HSDIO. The kit contains one clip to mount the NI SCB-68-HSDIO on a 35 mm DIN rail. To achieve this, you must first fasten the DIN rail clip to the enclosure using two flathead #6-32 × 1/4” screws with a #2 Phillips screwdriver. Most importantly, the user must not use the threaded holes on the NI SCB-68 HSDIO for DIN rail mounting more than 5 times. This is because repeatedly unscrewing and reinstalling the DIN rail clip might compromise the connection between the DIN rail clip and the enclosure.
When setting up SCB-68-HSDIO with the 783198-01, the user must also make sure that the hazardous voltage is not connected. For the connector block, voltages greater than 30 Vrms/42 Vpk/60 VDC are considered to be hazardous. Likewise, for signal connections, it is recommended that you use 50 Ω cables. Furthermore, to ensure EMC performance, signal wires outside of the enclosure must be properly shielded.
When using the 783198-01 with the SCB-58-HSDIO, the user must be aware of the environmental characteristics required for its proper operation. The ambient operating temperature range is 0 to 70 °C while the storage temperature is -20 to 70 °C. Likewise, you must also maintain a relative humidity of 5 to 90% RH. Furthermore, the maximum altitude where the device can be operated properly is 2000 m. Moreover, the 783198-01is meant for indoor use only.
Part Number | 783198-01 |
---|---|
Model Name | DIN Rail Kit For SCB-68-HSDIO |
Part Type | Mounting Kit |
Used With | SCB-68-HSDIO |
Tools Required | Two flathead #6-32 × 1/4” screws; a #2 Phillips screwdriver |
Hazardous Voltages | Voltages > 30 Vrms/42 Vpk/60 VDC |
Threaded Holes Use | No more than 5 times |
Operating Temperature (for SCB-68-HSDIO) | 0 to 70 °C |
Storage Temperature (for SCB-68-HSDIO) | -20 to 70 °C |
Maximum Altitude | 2000 m |
783198-01 PDF Manuals
SCB 68 HSDIO CONNECTION GUIDE AND SPECIFICATIONS.PDF
SCB 68 HSDIO DIMENSIONAL DRAWING.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
783198-01
Modular Systems > National Instruments > Accessories
783198-01, 35 mm DIN Rail, DIN Rail Kit for the NI SCB-68 HSDIO
1-800-915-6216
- Description
- Technical Specifications
- Manuals & PDFs
National Instruments 783198-01 DIN Rail Kit For SCB-68-HSDIO
Part Number 783198-01 is the identifying part number for the DIN Rail Kit for the National Instruments SCB-68-HSDIO. The kit contains one clip to mount the NI SCB-68-HSDIO on a 35 mm DIN rail. To achieve this, you must first fasten the DIN rail clip to the enclosure using two flathead #6-32 × 1/4” screws with a #2 Phillips screwdriver. Most importantly, the user must not use the threaded holes on the NI SCB-68 HSDIO for DIN rail mounting more than 5 times. This is because repeatedly unscrewing and reinstalling the DIN rail clip might compromise the connection between the DIN rail clip and the enclosure.
When setting up SCB-68-HSDIO with the 783198-01, the user must also make sure that the hazardous voltage is not connected. For the connector block, voltages greater than 30 Vrms/42 Vpk/60 VDC are considered to be hazardous. Likewise, for signal connections, it is recommended that you use 50 Ω cables. Furthermore, to ensure EMC performance, signal wires outside of the enclosure must be properly shielded.
When using the 783198-01 with the SCB-58-HSDIO, the user must be aware of the environmental characteristics required for its proper operation. The ambient operating temperature range is 0 to 70 °C while the storage temperature is -20 to 70 °C. Likewise, you must also maintain a relative humidity of 5 to 90% RH. Furthermore, the maximum altitude where the device can be operated properly is 2000 m. Moreover, the 783198-01is meant for indoor use only.
Part Number | 783198-01 |
---|---|
Model Name | DIN Rail Kit For SCB-68-HSDIO |
Part Type | Mounting Kit |
Used With | SCB-68-HSDIO |
Tools Required | Two flathead #6-32 × 1/4” screws; a #2 Phillips screwdriver |
Hazardous Voltages | Voltages > 30 Vrms/42 Vpk/60 VDC |
Threaded Holes Use | No more than 5 times |
Operating Temperature (for SCB-68-HSDIO) | 0 to 70 °C |
Storage Temperature (for SCB-68-HSDIO) | -20 to 70 °C |
Maximum Altitude | 2000 m |
783198-01 PDF Manuals & Diagrams
783198-01 PDF Manuals
SCB 68 HSDIO CONNECTION GUIDE AND SPECIFICATIONS.PDF
SCB 68 HSDIO DIMENSIONAL DRAWING.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"