786849-01, 10 MHz, 150 A, CC15010X Oscilloscope Probe
4.9/5 | 7 ratings
Fast Quote
Quoted Price

Need an Official Quote?

 

National Instruments 786849-01 Oscilloscope Probe

Part Number 786849-01 is the identifying part number for the National Instruments CC15010X Oscilloscope Probe. The 786849-01 has a -3 dB bandwidth ranging from DC to 10 MHz. The rise time for the probe is 35 ns or less. The maximum continuous input range for the probe is 150 A while the maximum peak current value is 300 A for non-continuous and 500 A at a pulse width of less than 30 μs. Similarly, the output voltage rate is 0.01 V/A.  Furthermore, the amplitude accuracy is as follows: ± 1.0 % rdg. ± 1 mV up to 150 A, ±2.0% rdg. for 150 A to 300 A peak (considering DC, and 45 to 66 Hz). Moreover, the noise is equivalent to 25 mA rms or less. 

The maximum rated power for the 786849-01 is 5.5 VA within the maximum continuous input range. The rated supply voltage for this probe is  ±12 V ±1 V. The temperature coefficient of sensitivity is ± 2% or less considering a 55 Hz 150 A input within the operating temperature range. In a DC or 60 Hz, 400 A/m magnetic field, the effect of the magnetic field can reach an equivalent to a maximum of 150 mA

The 786849-01 is recommended for operation between temperatures of  0 °C to 40 °C at a relative humidity of 80% or less. Likewise, it is designed for indoor use only and should be operated within a maximum altitude of 2000 m. On the other hand, it can be stored between  -10 °C to 50 °C at the same level of relative humidity. There is a 1 year period of guaranteed accuracy for the probe accounting for opening/closing up to 10000 times

The diameter of measurable conductors for the 786849-01 is 20 mm and it can measure insulated conductors. The length of the sensor cable is approximately 2 m while the length of the power supply cable is approximately 1 m. The probe weighs 500 g and comes with an instruction manual and a carrying case. It complies with the EN61010 safety and EN61326 EMC standards
 

Part Number786849-01
Model NameCC15010X
Part TypeOscilloscope Probe
Measure Frequency10 MHz
Probe TypeCurrent
Measure Current150 A
Maximum Rated Power5.5 VA
Output Voltage Rate0.01 V/A
Operating Temperature0 °C to 40 °C
Period of Guaranteed Accuracy1 year

  786849-01 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: 7O6849-01, 78Y849-01, 7868R9-01, 78684O-01, 786849-0W

786849-01



Modular Systems > National Instruments > Accessories

786849-01, 10 MHz, 150 A, CC15010X Oscilloscope Probe
4.9/5 | 7 ratings

Call now for best pricing
1-800-915-6216

National Instruments 786849-01 Oscilloscope Probe

Part Number 786849-01 is the identifying part number for the National Instruments CC15010X Oscilloscope Probe. The 786849-01 has a -3 dB bandwidth ranging from DC to 10 MHz. The rise time for the probe is 35 ns or less. The maximum continuous input range for the probe is 150 A while the maximum peak current value is 300 A for non-continuous and 500 A at a pulse width of less than 30 μs. Similarly, the output voltage rate is 0.01 V/A.  Furthermore, the amplitude accuracy is as follows: ± 1.0 % rdg. ± 1 mV up to 150 A, ±2.0% rdg. for 150 A to 300 A peak (considering DC, and 45 to 66 Hz). Moreover, the noise is equivalent to 25 mA rms or less. 

The maximum rated power for the 786849-01 is 5.5 VA within the maximum continuous input range. The rated supply voltage for this probe is  ±12 V ±1 V. The temperature coefficient of sensitivity is ± 2% or less considering a 55 Hz 150 A input within the operating temperature range. In a DC or 60 Hz, 400 A/m magnetic field, the effect of the magnetic field can reach an equivalent to a maximum of 150 mA

The 786849-01 is recommended for operation between temperatures of  0 °C to 40 °C at a relative humidity of 80% or less. Likewise, it is designed for indoor use only and should be operated within a maximum altitude of 2000 m. On the other hand, it can be stored between  -10 °C to 50 °C at the same level of relative humidity. There is a 1 year period of guaranteed accuracy for the probe accounting for opening/closing up to 10000 times

The diameter of measurable conductors for the 786849-01 is 20 mm and it can measure insulated conductors. The length of the sensor cable is approximately 2 m while the length of the power supply cable is approximately 1 m. The probe weighs 500 g and comes with an instruction manual and a carrying case. It complies with the EN61010 safety and EN61326 EMC standards
 

Part Number786849-01
Model NameCC15010X
Part TypeOscilloscope Probe
Measure Frequency10 MHz
Probe TypeCurrent
Measure Current150 A
Maximum Rated Power5.5 VA
Output Voltage Rate0.01 V/A
Operating Temperature0 °C to 40 °C
Period of Guaranteed Accuracy1 year

786849-01 PDF Manuals & Diagrams

  786849-01 PDF Manuals

CC5002X AND CC15010X SPECIFICATIONS.PDF


Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau