CAL-4330, 6.5 Digit, Calibration Fixture for Use With the PXIe-4330 and the PXIe-4331
Need an Official Quote?
National Instruments CAL-4330 Calibration Fixture
The National Instruments CAL-4330 (Part Numbers: 786988-01, 787003-01) Calibration Fixture is a vital component for preserving the precision and dependability of PXIe-4330 and PXIe-4331 devices. This fixture offers a controlled environment for testing and modifying different parameters, ensuring accurate calibration.
For optimal outcomes, use a Fluke 5520A/5522A calibrator with the CAL-4330. An alternate calibrator with similar specifications can be used if these particular models are not available. The necessary parameters are automated lead wire compensation, 2-wire output compensation, resistance values between 120 Ω and 1 kΩ with 0.01 Ω resolution, and an accuracy of 90 ppm or greater.
CAL-4330 comes with the cables needed to make connections easier. Two of these cables are 160-Pin DIN to 160-Pin DIN, which connect PXIe-2737 switch modules to the fixture. The other cable is a shielded cable (SH96F-96M-CAL4330), which connects the Device Under Test (DUT) to the CAL-4330.
Two DMMs, either PXI-4071 or PXIe-4081 devices, are among the test apparatus needed for calibration. These DMMs ought to be multiranging, with a 6 1/2-digit capability and an accuracy of at least 40 ppm for DC voltage and 80 ppm for resistance when measuring 4-wire resistance. Four PXIe-2737 switch modules are furthermore required for relay operations.
The CAL-4330 is designed to provide accurate readings in particular testing scenarios. It is advised to utilize twisted-pair wire to reduce noise and thermal offsets, use shielded copper wire for cable connections, and keep connections short to reduce noise interference. Stable operation conditions are achieved by keeping the relative humidity below 80% and the ambient temperature at 23°C ±5°C. In addition, it is advised to give the measurement circuitry at least 15 minutes to stabilize before running any experiments.
Model Name | CAL-4330 |
---|---|
Part Number(s) | 786988-01, 787003-01 |
Manufacturer | National Instruments (NI) |
Compatible Devices | PXIe-4330, PXIe-4331 |
Calibrator Compatibility | Fluke 5520A/5522A or equivalent |
Cable (DIN to DIN) | 160-Pin, NI part number 782417-02 (x2) |
Shielded Cable (DUT to CAL) | SH96F-96M-CAL4330, NI part number 787003-01 |
DMM Compatibility | PXI-4071 or PXIe-4081 or equivalent |
DMM Accuracy (DC Voltage) | 40 ppm of reading +6 ppm of range |
DMM Accuracy (Resistance) | 80 ppm of reading +6 ppm of range |
Switch Modules | PXIe-2737, 4x64 2-wire relay modules (x2) |
Test Conditions | Ambient temperature: 23 °C ±5 °C, Relative humidity: <80% |
National Instruments CAL-4330 Frequently Asked Questions
Why does the CAL-4330 have two part numbers?
Part number 786988-01 is the actual module, while Part number 787003-01 is a shielded cable for connecting the PXIe-4330/4331 to the CAL-4330.
Is the CAL-4330 compatible with other NI devices?
No, the CAL-4330 is specifically designed for the PXIe-4330/4331 modules.
What other devices are required to calibrate with the CAL-4330?
For optimal outcomes, use a Fluke 5520A/5522A calibrator with the CAL-4330. Two DMMs, either PXI-4071 or PXIe-4081 devices, are among the test apparatus needed for calibration. For relay operations, Four PXIe-2737 switch modules are furthermore required .
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
CAL-4330
Modular Systems > National Instruments > Accessories
CAL-4330, 6.5 Digit, Calibration Fixture for Use With the PXIe-4330 and the PXIe-4331
1-800-915-6216
- Description
- Technical Specifications
- Frequently Asked Questions
- Manuals & PDFs
National Instruments CAL-4330 Calibration Fixture
The National Instruments CAL-4330 (Part Numbers: 786988-01, 787003-01) Calibration Fixture is a vital component for preserving the precision and dependability of PXIe-4330 and PXIe-4331 devices. This fixture offers a controlled environment for testing and modifying different parameters, ensuring accurate calibration.
For optimal outcomes, use a Fluke 5520A/5522A calibrator with the CAL-4330. An alternate calibrator with similar specifications can be used if these particular models are not available. The necessary parameters are automated lead wire compensation, 2-wire output compensation, resistance values between 120 Ω and 1 kΩ with 0.01 Ω resolution, and an accuracy of 90 ppm or greater.
CAL-4330 comes with the cables needed to make connections easier. Two of these cables are 160-Pin DIN to 160-Pin DIN, which connect PXIe-2737 switch modules to the fixture. The other cable is a shielded cable (SH96F-96M-CAL4330), which connects the Device Under Test (DUT) to the CAL-4330.
Two DMMs, either PXI-4071 or PXIe-4081 devices, are among the test apparatus needed for calibration. These DMMs ought to be multiranging, with a 6 1/2-digit capability and an accuracy of at least 40 ppm for DC voltage and 80 ppm for resistance when measuring 4-wire resistance. Four PXIe-2737 switch modules are furthermore required for relay operations.
The CAL-4330 is designed to provide accurate readings in particular testing scenarios. It is advised to utilize twisted-pair wire to reduce noise and thermal offsets, use shielded copper wire for cable connections, and keep connections short to reduce noise interference. Stable operation conditions are achieved by keeping the relative humidity below 80% and the ambient temperature at 23°C ±5°C. In addition, it is advised to give the measurement circuitry at least 15 minutes to stabilize before running any experiments.
Model Name | CAL-4330 |
---|---|
Part Number(s) | 786988-01, 787003-01 |
Manufacturer | National Instruments (NI) |
Compatible Devices | PXIe-4330, PXIe-4331 |
Calibrator Compatibility | Fluke 5520A/5522A or equivalent |
Cable (DIN to DIN) | 160-Pin, NI part number 782417-02 (x2) |
Shielded Cable (DUT to CAL) | SH96F-96M-CAL4330, NI part number 787003-01 |
DMM Compatibility | PXI-4071 or PXIe-4081 or equivalent |
DMM Accuracy (DC Voltage) | 40 ppm of reading +6 ppm of range |
DMM Accuracy (Resistance) | 80 ppm of reading +6 ppm of range |
Switch Modules | PXIe-2737, 4x64 2-wire relay modules (x2) |
Test Conditions | Ambient temperature: 23 °C ±5 °C, Relative humidity: <80% |
National Instruments CAL-4330 Frequently Asked Questions
Why does the CAL-4330 have two part numbers?
Part number 786988-01 is the actual module, while Part number 787003-01 is a shielded cable for connecting the PXIe-4330/4331 to the CAL-4330.
Is the CAL-4330 compatible with other NI devices?
No, the CAL-4330 is specifically designed for the PXIe-4330/4331 modules.
What other devices are required to calibrate with the CAL-4330?
For optimal outcomes, use a Fluke 5520A/5522A calibrator with the CAL-4330. Two DMMs, either PXI-4071 or PXIe-4081 devices, are among the test apparatus needed for calibration. For relay operations, Four PXIe-2737 switch modules are furthermore required .
CAL-4330 PDF Manuals & Diagrams
CAL-4330 PDF Manuals
CAL-4330 DIMENSIONAL DRAWINGS.PDF
CALIBRATION EXECUTIVE USER MANUAL.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."