National Instruments NI-9482 C Series Relay Output Module
The NI-9482 (Part numbers: 783906-01 and 782999-01) is a C Series Relay Output Module manufactured by National Instruments. It is specifically developed for a wide range of industrial devices, such as suitable for actuators, DC devices, and motors. The NI 9482 Relay Module fulfils the monitoring limits for EMC. These limits are mandatory for safety against harmful intrusion. This module has four electromechanical relay channels. Each channel has two switchable pins (Cha and CHb). 2 wire ferrules are used to generate a safe connection in the NI 9482, which is used when the module is subjected to high vibration.
The NI 9842 module is structured with LED circuits. These LED circuits direct the current state of each channel. The LED will light up when a channel is on. The LED becomes dark when a channel is off. The LED circuits are disabled when the chassis is in sleep mode. The NI-9482 has a screw terminal front connector which is easily removable–another model of the same device is equipped with a spring terminal connector. The NI-9482 is also featured with 10 terminal connectors. The NI-9482 assists a low power sleep mode. It depends on the chassis to which the module is connected. The module consumes less power and release less heat in sleep mode. It has a power consumption of up to 580 mW when active, and 10 mW maximum when in sleep mode.
The NI-9482 has 4 digital output channels with single pole single throw (SPST) technology. Each channel is capable of switching signals up to 30 VDC, 60 VDC, and 250 VDC. All channels are electrically isolated from each other. The channels with 250 Vrms of continuous isolation are earth ground. The output channels have a switching rate of 1 operation per second, a relay release, operate and bounce time of 10 ms max, 15 ms max, and 3 ms respectively.
The NI device weighs 5.3 oz. It has a recommended operating temperature range of -40 °C to 70 °C, a storage temperature range of -40 °C to 85 °C, and a noncondensing operating and storage humidity of 10% to 90% RH and 5% to 95% RH respectively.
Model | NI-9482 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 783906-01, 782999-01 |
Type | C Series Relay Output Module |
Digital Output Channels | 4 |
Maximum Switching Voltage AC | 250 V |
Maximum Switching Voltage DC | 60 V |
Front Connector | Spring Terminal or Screw Terminal |
Weight | 5.3 oz. |
Warranty | Three Year Warranty |
NI-9482 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the NI-9482:
155304A-01L, 155304A-06L, 155304B-01L, 155304B-04L, 155304B-06L, 155304C-01L, 189419F-02L, 200384A-01, 782999-01, 783906-01
National Instruments NI-9482 Frequently Asked Questions
Question: What is the difference between the two part numbers for the NI-9482?
Answer: The NI-9482 has two types of front connectors available. Part number 782999-01 has a screw terminal front connector and part number 783906-01 has a spring terminal front connector.
Question: Does the NI 9482 Relay Module require any accessories for operation?
Answer: Yes, the NI 9482 Relay Module requires the NI 9927 Connector Backshell Kit.
Question: Which drivers can be used with the NI 9482?
Answer: NI-DAQmx and NI-RIO can be used with the NI 9482.
Question: What is the switching voltage of the output channels on the NI-9482?
Answer: The switching voltage of the output channels on the NI-9482 is 60 VDC max, 250 Vrms max.
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
NI-9482
Modular Systems > National Instruments > C Series
NI-9482, 4-Channel, SPST Relay, C Series Relay Output Module
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments NI-9482 C Series Relay Output Module
The NI-9482 (Part numbers: 783906-01 and 782999-01) is a C Series Relay Output Module manufactured by National Instruments. It is specifically developed for a wide range of industrial devices, such as suitable for actuators, DC devices, and motors. The NI 9482 Relay Module fulfils the monitoring limits for EMC. These limits are mandatory for safety against harmful intrusion. This module has four electromechanical relay channels. Each channel has two switchable pins (Cha and CHb). 2 wire ferrules are used to generate a safe connection in the NI 9482, which is used when the module is subjected to high vibration.
The NI 9842 module is structured with LED circuits. These LED circuits direct the current state of each channel. The LED will light up when a channel is on. The LED becomes dark when a channel is off. The LED circuits are disabled when the chassis is in sleep mode. The NI-9482 has a screw terminal front connector which is easily removable–another model of the same device is equipped with a spring terminal connector. The NI-9482 is also featured with 10 terminal connectors. The NI-9482 assists a low power sleep mode. It depends on the chassis to which the module is connected. The module consumes less power and release less heat in sleep mode. It has a power consumption of up to 580 mW when active, and 10 mW maximum when in sleep mode.
The NI-9482 has 4 digital output channels with single pole single throw (SPST) technology. Each channel is capable of switching signals up to 30 VDC, 60 VDC, and 250 VDC. All channels are electrically isolated from each other. The channels with 250 Vrms of continuous isolation are earth ground. The output channels have a switching rate of 1 operation per second, a relay release, operate and bounce time of 10 ms max, 15 ms max, and 3 ms respectively.
The NI device weighs 5.3 oz. It has a recommended operating temperature range of -40 °C to 70 °C, a storage temperature range of -40 °C to 85 °C, and a noncondensing operating and storage humidity of 10% to 90% RH and 5% to 95% RH respectively.
Model | NI-9482 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 783906-01, 782999-01 |
Type | C Series Relay Output Module |
Digital Output Channels | 4 |
Maximum Switching Voltage AC | 250 V |
Maximum Switching Voltage DC | 60 V |
Front Connector | Spring Terminal or Screw Terminal |
Weight | 5.3 oz. |
Warranty | Three Year Warranty |
NI-9482 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments NI-9482 Frequently Asked Questions
Question: What is the difference between the two part numbers for the NI-9482?
Answer: The NI-9482 has two types of front connectors available. Part number 782999-01 has a screw terminal front connector and part number 783906-01 has a spring terminal front connector.
Question: Does the NI 9482 Relay Module require any accessories for operation?
Answer: Yes, the NI 9482 Relay Module requires the NI 9927 Connector Backshell Kit.
Question: Which drivers can be used with the NI 9482?
Answer: NI-DAQmx and NI-RIO can be used with the NI 9482.
Question: What is the switching voltage of the output channels on the NI-9482?
Answer: The switching voltage of the output channels on the NI-9482 is 60 VDC max, 250 Vrms max.
NI-9482 PDF Manuals & Diagrams
NI-9482 PDF Manuals