Modular Systems > National Instruments > C Series




Or speak to a sales representative for additional information:
NI-9770 Request for Availablility
NI-9770, 1-Channel, C Series RF Receiver Module
Need an Official Quote?
National Instruments NI-9770 C Series RF Receiver Module
The NI‑9770 (Part number: 783895-01) is a solitary channel module intended for machine condition observing applications. The NI‑9770 can quantify RF emanations. This data transfer capacity can be designed as a tight range to help recognize electrical irregularities, frequently thought about a main marker of machine failure. This model can identify practical release, crown release, arcing, and whatever other marvels that are the outcome of RF outflows. Users can perform electromagnetic signature analysis (EMSA) by observing signals over some stretch of time utilizing a cleared frequency portrayal. The NI 9770 module measures RF emanations in the frequency scope of 30 kHz to 100 MHz by utilizing a tight configurable data transfer capacity to help identify electrical peculiarities, which can be a main marker of machine disappointment. The SMA connectors on the NI 9770 give reception apparatus network and enable the CompactRIO framework to be introduced for the most extreme uptime. Topic specialists can screen motions after some time utilizing the cleared frequency portrayal to perform Electromagnetic Signature Analysis (EMSA). The circuit's output to the RIO FPGA goes high when the information voltage is more noteworthy than the physically set edge voltage. The output goes low when the information is not as much as the physically set limit voltage.
This model offers 1 channel, 320 kS/s, support for RF discharges estimations from 30 kHz to 100 MHz, software-selectable data transfer capacity from 3.2 kHz to 256 kHz, 104 dB dynamic range, provides equipment recognition of aggregate power in the frequency range and time space examination, and SMA connectors.
Model | NI-9770 |
---|---|
Manufacturer | National Instruments |
Part Number | 783895-01 |
Type | C Series RF Receiver Module |
Channels | 1 |
Frequency Range | 300 kHz to 100 MHz |
Bandwidth | 3.2 kHz to 256 kHz |
Dynamic Range | 104 dB |
Weight | 5.6 oz. |
Warranty | 2-3 Year Warranty |
NI-9770 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the NI-9770:
156260A-01L, 156260B-01L, 156260C-01L, 156260D-01L, 156828A-01L, 156828B-01L, 156828C-01L, 156828D-01L, 783895-01
National Instruments NI-9770 Frequently Asked Questions
Question: Does the NI 9770 module require any accessories?
Answer: The NI 9770 module requires a 50 Ohm SMA Male to SMA Male Cable with a length of either 12.7 cm (Part Number: 763443-01) or 38.1 cm (Part Number: 763444-01).
Question: Which types of electrical phenomena can the NI-9770 detect?
Answer: A few of the types of electrical phenomena that the NI-9770 can detect include arcing, partial discharge, corona discharge, and other types of phenomena that cause RF emissions.
Question: What are the power requirements for the NI 9770?
Answer: The power requirements for the NI 9770 are 1 W maximum for thermal dissipation and 25 μW maximum in sleep mode for the power consumption from chassis.
Question: Can the NI-9770 be used with an SMA antenna?
Answer: No, the NI-9770 is not compatible with SMA antennas.
NI-9770 PDF Manuals
NI-9770 GETTING STARTED GUIDE.PDF
NI-9770 LETTER OF VOLATILITY.PDF
NI CMS 9065 NI MMS 9065 AND NI EMSA 9065 MAINTAINING HARDWARE.PDF
NI CMS 9068 NI MMS 9068 AND NI EMSA 9068 MAINTAINING HARDWARE.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
NI-9770
Modular Systems > National Instruments > C Series
NI-9770, 1-Channel, C Series RF Receiver Module
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments NI-9770 C Series RF Receiver Module
The NI‑9770 (Part number: 783895-01) is a solitary channel module intended for machine condition observing applications. The NI‑9770 can quantify RF emanations. This data transfer capacity can be designed as a tight range to help recognize electrical irregularities, frequently thought about a main marker of machine failure. This model can identify practical release, crown release, arcing, and whatever other marvels that are the outcome of RF outflows. Users can perform electromagnetic signature analysis (EMSA) by observing signals over some stretch of time utilizing a cleared frequency portrayal. The NI 9770 module measures RF emanations in the frequency scope of 30 kHz to 100 MHz by utilizing a tight configurable data transfer capacity to help identify electrical peculiarities, which can be a main marker of machine disappointment. The SMA connectors on the NI 9770 give reception apparatus network and enable the CompactRIO framework to be introduced for the most extreme uptime. Topic specialists can screen motions after some time utilizing the cleared frequency portrayal to perform Electromagnetic Signature Analysis (EMSA). The circuit's output to the RIO FPGA goes high when the information voltage is more noteworthy than the physically set edge voltage. The output goes low when the information is not as much as the physically set limit voltage.
This model offers 1 channel, 320 kS/s, support for RF discharges estimations from 30 kHz to 100 MHz, software-selectable data transfer capacity from 3.2 kHz to 256 kHz, 104 dB dynamic range, provides equipment recognition of aggregate power in the frequency range and time space examination, and SMA connectors.
Model | NI-9770 |
---|---|
Manufacturer | National Instruments |
Part Number | 783895-01 |
Type | C Series RF Receiver Module |
Channels | 1 |
Frequency Range | 300 kHz to 100 MHz |
Bandwidth | 3.2 kHz to 256 kHz |
Dynamic Range | 104 dB |
Weight | 5.6 oz. |
Warranty | 2-3 Year Warranty |
NI-9770 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments NI-9770 Frequently Asked Questions
Question: Does the NI 9770 module require any accessories?
Answer: The NI 9770 module requires a 50 Ohm SMA Male to SMA Male Cable with a length of either 12.7 cm (Part Number: 763443-01) or 38.1 cm (Part Number: 763444-01).
Question: Which types of electrical phenomena can the NI-9770 detect?
Answer: A few of the types of electrical phenomena that the NI-9770 can detect include arcing, partial discharge, corona discharge, and other types of phenomena that cause RF emissions.
Question: What are the power requirements for the NI 9770?
Answer: The power requirements for the NI 9770 are 1 W maximum for thermal dissipation and 25 μW maximum in sleep mode for the power consumption from chassis.
Question: Can the NI-9770 be used with an SMA antenna?
Answer: No, the NI-9770 is not compatible with SMA antennas.
NI-9770 PDF Manuals & Diagrams
NI-9770 PDF Manuals
NI-9770 GETTING STARTED GUIDE.PDF
NI-9770 LETTER OF VOLATILITY.PDF
NI CMS 9065 NI MMS 9065 AND NI EMSA 9065 MAINTAINING HARDWARE.PDF
NI CMS 9068 NI MMS 9068 AND NI EMSA 9068 MAINTAINING HARDWARE.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."