NI-9967, Screw Terminal, Strain Relief and Operator Protection Accessory
Need an Official Quote?
National Instruments NI-9967 Screw Terminal Strain Relief and Operator Protection Accessory (NI-9242 C Series Voltage Input Module accessory)
The NI-9967 (Part Numbers: 783094-01 and 156514A-01 [Rev A or higher]) is a screw terminal strain relief and operator protection accessory made to accommodate the National Instruments NI-9242 (Part Number: 783107-01) 3-Channel, 24-Bit Voltage Input Module. It is a useful and highly recommended accessory for high vibration and/or high voltage applications. The NI-9967 should be used for applications involving a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground. The NI-9967 connector back shell accessory ensures that the terminals are not accessible to operators.
The National Instruments NI-9967 screw terminal strain relief and operator protection accessory is a back shell that attaches to the 4-terminal connector on the NI-9242. The NI-9967 assembly can connect single- or three-phase measurement configurations.
To install the NI-9967 screw terminal strain relief and operator protection accessory, the following wires may be used: 12 AWG to 14 AWG, 16 AWG, and 18 AWG to 24 AWG. The selected wires determine the method of installation. To install the NI-9967 Using 12 AWG to 14 AWG Wire, Route wires under the smallest strain-relief piece. When installing the NI-9967 using the 16 AWG wire, Route wires between the two strain-relief pieces, with the small strain-relief piece on top of the wires and the large strain-relief piece underneath the wires. To install the NI-9967 using the 18 AWG to 24 AWG wire, Route wires under the largest strain-relief piece. Once wires have been properly routed within the assembly, secure the NI-9967 screw terminal strain relief and operator protection accessory pieces in place using screws.
The NI-9967 is a terminal accessory that ensures potentially hazardous voltages of the NI-9242 are shielded from human contact. The NI-9967 corresponds to the C series analog input modules. The assembly including the NI-9967 offers several channels for measurements between the neutral and signal channels and between the neutral terminal and ground. The NI-9967 screw terminal strain relief and operator protection accessory for signal wire security and high-voltage protection enables safe operation of the NI-9242.
Associated part numbers for the NI-9967:
156514A-01, 783094-01
National Instruments NI-9967 Screw Terminal Strain Relief and Operator Protection Accessory FAQs
Question: What applications is the NI-9967 recommended for?
Answer: The NI-9967 is highly recommended for use in applications with high vibrations and / or high voltage.
Question: How do I install the NI-9967 with the different AWG wires?
Answer: The NI-9967 can be installed in the following ways. With the 12 to 14 AWG wire, wires must be routed under the smallest strain-relief piece. With the 16 AWG wire, wires must be routed between the two strain relief pieces, with the smallest on top and the largest underneath. With the 18 to 24 AWG wire, the wires must be routed under the large strain relief piece.
Question: Where does the NI-9967 attach?
Answer: The NI-9967 attaches to the 4-terminal connector on the NI-9242.
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
NI-9967
Modular Systems > National Instruments > C Series
NI-9967, Screw Terminal, Strain Relief and Operator Protection Accessory
1-800-915-6216
- Description
- Technical Specifications
- FAQ
National Instruments NI-9967 Screw Terminal Strain Relief and Operator Protection Accessory (NI-9242 C Series Voltage Input Module accessory)
The NI-9967 (Part Numbers: 783094-01 and 156514A-01 [Rev A or higher]) is a screw terminal strain relief and operator protection accessory made to accommodate the National Instruments NI-9242 (Part Number: 783107-01) 3-Channel, 24-Bit Voltage Input Module. It is a useful and highly recommended accessory for high vibration and/or high voltage applications. The NI-9967 should be used for applications involving a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground. The NI-9967 connector back shell accessory ensures that the terminals are not accessible to operators.
The National Instruments NI-9967 screw terminal strain relief and operator protection accessory is a back shell that attaches to the 4-terminal connector on the NI-9242. The NI-9967 assembly can connect single- or three-phase measurement configurations.
To install the NI-9967 screw terminal strain relief and operator protection accessory, the following wires may be used: 12 AWG to 14 AWG, 16 AWG, and 18 AWG to 24 AWG. The selected wires determine the method of installation. To install the NI-9967 Using 12 AWG to 14 AWG Wire, Route wires under the smallest strain-relief piece. When installing the NI-9967 using the 16 AWG wire, Route wires between the two strain-relief pieces, with the small strain-relief piece on top of the wires and the large strain-relief piece underneath the wires. To install the NI-9967 using the 18 AWG to 24 AWG wire, Route wires under the largest strain-relief piece. Once wires have been properly routed within the assembly, secure the NI-9967 screw terminal strain relief and operator protection accessory pieces in place using screws.
The NI-9967 is a terminal accessory that ensures potentially hazardous voltages of the NI-9242 are shielded from human contact. The NI-9967 corresponds to the C series analog input modules. The assembly including the NI-9967 offers several channels for measurements between the neutral and signal channels and between the neutral terminal and ground. The NI-9967 screw terminal strain relief and operator protection accessory for signal wire security and high-voltage protection enables safe operation of the NI-9242.
National Instruments NI-9967 Screw Terminal Strain Relief and Operator Protection Accessory FAQs
Question: What applications is the NI-9967 recommended for?
Answer: The NI-9967 is highly recommended for use in applications with high vibrations and / or high voltage.
Question: How do I install the NI-9967 with the different AWG wires?
Answer: The NI-9967 can be installed in the following ways. With the 12 to 14 AWG wire, wires must be routed under the smallest strain-relief piece. With the 16 AWG wire, wires must be routed between the two strain relief pieces, with the smallest on top and the largest underneath. With the 18 to 24 AWG wire, the wires must be routed under the large strain relief piece.
Question: Where does the NI-9967 attach?
Answer: The NI-9967 attaches to the 4-terminal connector on the NI-9242.