Modular Systems > National Instruments > Compact FieldPoint




Or speak to a sales representative for additional information:
cFP-DI-301 In Stock | Ships Today
cFP-DI-301, 16-Channel, Sinking Digital Input Module for Compact FieldPoint
Need an Official Quote?
National Instruments cFP-DI-301 Digital Input Module for Compact FieldPoint
The cFP-DI-301 (Part number: 777318-301) is a Sinking Digital Input Module designed for Compact FieldPoint. In Toggle, Reset On mode, the output channel begins high and goes low when the terminal check is surpassed. The yield channel comes back to whenever the terminal tally is surpassed or when the user sends a reset summon to the related check input channel. The terminal check is 4. The constant working framework can appoint needs to each control cycle. A control part of an application can keep running at high need while a less critical correspondence or information stockpiling can be executed at a lower need. This implies various PID cycles are executed continuously to guarantee soundness of the procedure while an interface with the client (HMI) is executed at a lower need. The real-time working framework ensures that the PID counts get processor assets when required while the HMI utilizes free cycles. The device is equipped with 16 input channels with an input range of 18 to 30 VDC, and an all channel update rate of 1 kHz.
Smaller FieldPoint modules incorporate Ethernet capacities, so the user can easily convey knowledge and control inside a manufacturing plant or generation plant. Nonetheless, past the capacity to disperse estimation and control, Compact FieldPoint is one of the stages simpler to use for Data Acquisition, since it offers a brief timeframe until the principal estimation. Both the design of the hardware and the interface Application programming (API) are basic and simple to use on the NI cFP-DI-301. Furthermore, the gear has worked in flag molding for quick and direct association of the sensors. With this engineering, it is anything but difficult to construct dispersed applications. The user can set up information logging stations for screen flags, such as temperature, weight, and stream; track the state of valves; and store the information locally or transmit it through the Ethernet interface.
The NI device weighs 3.6 oz, and measures 5.00 x 2.80 x 0.94 in. in physical dimensions. It has recommended operating and storage temperature ranges of –40 to 70 °C and –55 to 85 °C respectively.
Model | cFP-DI-301 |
---|---|
Manufacturer | National Instruments |
Part Number | 777318-301 |
Type | Digital Input Module for Compact FieldPoint |
Input Channels | 16 |
Input Range | 18 to 30 VDC |
All Channel Update Rate | 1 kHz |
Dimensions | 5.00 x 2.6 x 0.94 in. |
Weight | 3.6 oz. |
Warranty | Three Year Warranty |
cFP-DI-301 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the cFP-DI-301:
184241B-01, 184241C-01, 184241D-01, 184241E-01L, 184437B-01, 184437B-02, 184437C-02, 184437D-02L, 777318-301
Associated NSNs for the cFP-DI-301:
5998-01-538-1538 (5998015381538)
National Instruments cFP-DI-301 Frequently Asked Questions
Question: How do I measure the time between a 0-to-1 transition and a 1-to-0 transition on my cFP-DI-301?
Answer: To measure the time between a 0-to-1 transition and a 1-to-0 transition on the cFP-DI-301, you need to poll the digital input line (FP Read.vi) with a regular time interval and use the timestamp as the time reference.
Question: How does the NI cFP-DI-301 mount?
Answer: The NI cFP-DI-301 mounts on a FieldPoint terminal base, which provides operating power to the module.
Question: How many current-limited input channels does the National Instruments cFP-DI-301 have?
Answer: The National Instruments cFP-DI-301 has 16 current-limited channels.
cFP-DI-301 PDF Manuals
FIELDPOINT SAFETY AND RADIO FREQUENCY INTERFERENCE READ ME FIRST.PDF
FP DI 301 AND CFP DI 301 OPERATING INSTRUCTIONS.PDF
USING FIELDPOINT AND COMPACT FIELDPOINT SAFELY IN HAZARDOUS LOCATIONS 5BNOTE TO USERS5D.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
cFP-DI-301
Modular Systems > National Instruments > Compact FieldPoint
cFP-DI-301, 16-Channel, Sinking Digital Input Module for Compact FieldPoint
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments cFP-DI-301 Digital Input Module for Compact FieldPoint
The cFP-DI-301 (Part number: 777318-301) is a Sinking Digital Input Module designed for Compact FieldPoint. In Toggle, Reset On mode, the output channel begins high and goes low when the terminal check is surpassed. The yield channel comes back to whenever the terminal tally is surpassed or when the user sends a reset summon to the related check input channel. The terminal check is 4. The constant working framework can appoint needs to each control cycle. A control part of an application can keep running at high need while a less critical correspondence or information stockpiling can be executed at a lower need. This implies various PID cycles are executed continuously to guarantee soundness of the procedure while an interface with the client (HMI) is executed at a lower need. The real-time working framework ensures that the PID counts get processor assets when required while the HMI utilizes free cycles. The device is equipped with 16 input channels with an input range of 18 to 30 VDC, and an all channel update rate of 1 kHz.
Smaller FieldPoint modules incorporate Ethernet capacities, so the user can easily convey knowledge and control inside a manufacturing plant or generation plant. Nonetheless, past the capacity to disperse estimation and control, Compact FieldPoint is one of the stages simpler to use for Data Acquisition, since it offers a brief timeframe until the principal estimation. Both the design of the hardware and the interface Application programming (API) are basic and simple to use on the NI cFP-DI-301. Furthermore, the gear has worked in flag molding for quick and direct association of the sensors. With this engineering, it is anything but difficult to construct dispersed applications. The user can set up information logging stations for screen flags, such as temperature, weight, and stream; track the state of valves; and store the information locally or transmit it through the Ethernet interface.
The NI device weighs 3.6 oz, and measures 5.00 x 2.80 x 0.94 in. in physical dimensions. It has recommended operating and storage temperature ranges of –40 to 70 °C and –55 to 85 °C respectively.
Model | cFP-DI-301 |
---|---|
Manufacturer | National Instruments |
Part Number | 777318-301 |
Type | Digital Input Module for Compact FieldPoint |
Input Channels | 16 |
Input Range | 18 to 30 VDC |
All Channel Update Rate | 1 kHz |
Dimensions | 5.00 x 2.6 x 0.94 in. |
Weight | 3.6 oz. |
Warranty | Three Year Warranty |
cFP-DI-301 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments cFP-DI-301 Frequently Asked Questions
Question: How do I measure the time between a 0-to-1 transition and a 1-to-0 transition on my cFP-DI-301?
Answer: To measure the time between a 0-to-1 transition and a 1-to-0 transition on the cFP-DI-301, you need to poll the digital input line (FP Read.vi) with a regular time interval and use the timestamp as the time reference.
Question: How does the NI cFP-DI-301 mount?
Answer: The NI cFP-DI-301 mounts on a FieldPoint terminal base, which provides operating power to the module.
Question: How many current-limited input channels does the National Instruments cFP-DI-301 have?
Answer: The National Instruments cFP-DI-301 has 16 current-limited channels.
cFP-DI-301 PDF Manuals & Diagrams
cFP-DI-301 PDF Manuals
FIELDPOINT SAFETY AND RADIO FREQUENCY INTERFERENCE READ ME FIRST.PDF
FP DI 301 AND CFP DI 301 OPERATING INSTRUCTIONS.PDF
USING FIELDPOINT AND COMPACT FIELDPOINT SAFELY IN HAZARDOUS LOCATIONS 5BNOTE TO USERS5D.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."