National Instruments PXIe-4468 PXI Sound and Vibration Module
The PXIe-4468 from National Instruments (Part Numbers: 788512-01, 788511-01) is the perfect PXI Sound and Vibration Module for making highly precise measurements with microphones, accelerometers, and other transducers that feature large dynamic ranges. The PXIe-4468 is designed to meet the needs of various sound and vibration applications, including audio testing, automotive NVH, and machine condition monitoring. It is equipped with several features to enable accurate and reliable results consistently. Part number 788512-01 features a Mini-XLR front connector, while part number 788511-01 has a BNC front connector type.
The PXIe-4468 has two-channel dynamic signal generation and two-channel acquisition, making it a great option for meeting a variety of testing requirements. It provides versatility and robustness necessary for getting the job done effectively. You can use one of six gain settings to configure your input range, allowing you to tailor the module to the specific requirements of your application. Further, this module comes with AC/DC coupling, IEPE conditioning and a built-in tone generator; thus making it a comprehensive and single solution for sound and vibration testing requirements.
The output stage of the PXIe-4468 is a differential amplifier that can be configured to pseudodifferential mode in software. When configured in pseudodifferential mode, the -AO terminal is internally connected to chassis ground through a 50 Ω resistor, introducing a gain difference in the output stage of -22.0 mdB, which is automatically corrected by the software. The module can also be configured to pseudodifferential mode by making an external connection between +AOn or -AOn to chassis ground, which introduces a gain change of -22.0 mdB that is not corrected by the software. For most applications, configuring the output stage in differential mode will provide the best performance.
To achieve improved common-mode noise rejection, it is highly recommended to make a connection between the chassis ground of the PXIe-4468 and the input device ground. This connection is especially critical when the input device is isolated, and if this connection is not available, it may be better to configure the output stage in pseudodifferential mode. Overall, the PXIe-4468 is a highly capable and versatile module that provides a comprehensive solution for sound and vibration testing applications. With its multiple channels, configurable gain settings, and software-controlled features, it allows you to achieve highly accurate and reliable results.
Model | PXIe-4468 |
---|---|
Part Numbers | 788512-01, 788511-01 |
Type | PXI LCR Meter |
Analog Input / Output Connector | BNC Female, Mini-XLR Male |
Digital Trigger Connector | SMB Male |
Slot Compatibility | x1 and x4 PXI Express or PXI Express hybrid slots |
Dimensions | 6.3 in. x 3.9 in. (without connectors) |
Weight | 12.7 oz |
Warranty | Three Year Warranty |
PXIe-4468 Manuals | Manuals Available for Download |
Associated part numbers for the PXIe-4468:
130265B-21L, 130265B-22L, 131136B-21L, 131136B-22L, 131136C-21L, 131136C-22L, 136687A-01L, 136687B-01L, 788511-01, 788512-01
National Instruments PXIe-4468 Frequently Asked Questions
Question: What is the sample rate range of the PXIe-4468?
Answer: The PXIe-4468 has a sample rate range of 100 S/s to 250 kS/s
Question: What is the PXIe-4468's FIFO buffer size?
Answer: The FIFO buffer size of the PXIe-4468 is 1,023 samples.
Question: Does the PXIe-4468 have overvoltage protections?
Answer: Yes, the PXIe-4468 has overvoltage protections of ±42.4 V for all of the input configurations.
PXIe-4468 PDF Manuals
PXIE 4468_CALIBRATION_PROCEDURE.PDF
PXIE 4468_GETTING_STARTED_GUIDE.PDF
PXIE 4468_LETTER_OF_VOLATILITY.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-4468
Modular Systems > National Instruments > DSA Devices
PXIe-4468, 2 AO, 2 AI, PXI Sound and Vibration DSA Device
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments PXIe-4468 PXI Sound and Vibration Module
The PXIe-4468 from National Instruments (Part Numbers: 788512-01, 788511-01) is the perfect PXI Sound and Vibration Module for making highly precise measurements with microphones, accelerometers, and other transducers that feature large dynamic ranges. The PXIe-4468 is designed to meet the needs of various sound and vibration applications, including audio testing, automotive NVH, and machine condition monitoring. It is equipped with several features to enable accurate and reliable results consistently. Part number 788512-01 features a Mini-XLR front connector, while part number 788511-01 has a BNC front connector type.
The PXIe-4468 has two-channel dynamic signal generation and two-channel acquisition, making it a great option for meeting a variety of testing requirements. It provides versatility and robustness necessary for getting the job done effectively. You can use one of six gain settings to configure your input range, allowing you to tailor the module to the specific requirements of your application. Further, this module comes with AC/DC coupling, IEPE conditioning and a built-in tone generator; thus making it a comprehensive and single solution for sound and vibration testing requirements.
The output stage of the PXIe-4468 is a differential amplifier that can be configured to pseudodifferential mode in software. When configured in pseudodifferential mode, the -AO terminal is internally connected to chassis ground through a 50 Ω resistor, introducing a gain difference in the output stage of -22.0 mdB, which is automatically corrected by the software. The module can also be configured to pseudodifferential mode by making an external connection between +AOn or -AOn to chassis ground, which introduces a gain change of -22.0 mdB that is not corrected by the software. For most applications, configuring the output stage in differential mode will provide the best performance.
To achieve improved common-mode noise rejection, it is highly recommended to make a connection between the chassis ground of the PXIe-4468 and the input device ground. This connection is especially critical when the input device is isolated, and if this connection is not available, it may be better to configure the output stage in pseudodifferential mode. Overall, the PXIe-4468 is a highly capable and versatile module that provides a comprehensive solution for sound and vibration testing applications. With its multiple channels, configurable gain settings, and software-controlled features, it allows you to achieve highly accurate and reliable results.
Model | PXIe-4468 |
---|---|
Part Numbers | 788512-01, 788511-01 |
Type | PXI LCR Meter |
Analog Input / Output Connector | BNC Female, Mini-XLR Male |
Digital Trigger Connector | SMB Male |
Slot Compatibility | x1 and x4 PXI Express or PXI Express hybrid slots |
Dimensions | 6.3 in. x 3.9 in. (without connectors) |
Weight | 12.7 oz |
Warranty | Three Year Warranty |
PXIe-4468 Manuals | Manuals Available for Download |
National Instruments PXIe-4468 Frequently Asked Questions
Question: What is the sample rate range of the PXIe-4468?
Answer: The PXIe-4468 has a sample rate range of 100 S/s to 250 kS/s
Question: What is the PXIe-4468's FIFO buffer size?
Answer: The FIFO buffer size of the PXIe-4468 is 1,023 samples.
Question: Does the PXIe-4468 have overvoltage protections?
Answer: Yes, the PXIe-4468 has overvoltage protections of ±42.4 V for all of the input configurations.
PXIe-4468 PDF Manuals & Diagrams
PXIe-4468 PDF Manuals
PXIE 4468_CALIBRATION_PROCEDURE.PDF
PXIE 4468_GETTING_STARTED_GUIDE.PDF
PXIE 4468_LETTER_OF_VOLATILITY.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."