Modular Systems > National Instruments > FieldDAQ

National Instruments - FieldDAQ - 785639-01National Instruments - FieldDAQ - 785639-01 - Wiring785639-01 New785639-01 | Legacy, Refurbished and New Surplus
National Instruments - FieldDAQ - 785639-01
National Instruments - FieldDAQ - 785639-01 - Wiring
785639-01 New
785639-01 | Legacy, Refurbished and New Surplus
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping

Or speak to a sales representative for additional information:


785639-01 Request for Availablility

785639-01, 8 Channels, 24 Bits, FD-11603 Voltage Input Device
5/5 | 11 ratings
Fast Quote
Quoted Price

Need an Official Quote?

 

National Instruments 785639-01 Voltage Input Device for FieldDAQ

Part Number 785639-01 identifies the National Instruments FD-11603 Voltage Input Device for FieldDAQ. The 785639-01 features 8 analog input channels with galvanic isolation between the channels and the chassis. Likewise, the device has a Delta-sigma ADC with a resolution of 24 bits and analog prefiltering. The input channels support a voltage range of ±10.5 V. The timebase frequency can be configured to 13.1072 MHz, 12.8 MHz, 12.288 MHz, and 10.24 MHz, with an accuracy of ±30 ppm maximum. The sample rate ranges from a minimum of 500 samples/s to a maximum of 102.4 kSamples/s.

This 785639-01 supports TCP/IP and UDP protocols, using a variety of network ports: HTTP:80 (configuration only), TCP:3580; UDP:5353 (configuration only), TCP:5353 (configuration only); TCP:31415; UDP:7865 (configuration only), and UDP:8473 (configuration only). It has a default MTU size of 1500 bytes. Additionally, it has two internally-switched 8-pin X-coded M12 ports for Ethernet communication. The communication rates are auto-negotiated between 10/100/1000 Mbps. The maximum cabling distance is 100 meters per segment, with a maximum of 15 hops per line. Furthermore, it uses IEEE 802.1AS protocol for network synchronization over 1000 Base-TX interface.

The 785639-01 supports an input voltage range of 9 VDC to 30 VDC, with a maximum power consumption of 7.5 W. Both power input and output use a 5-pin L-coded male M12 connector. The recommended torque for M12 connectors is 0.6 Nm. The maximum current for the Power IN/OUT terminals is 10 A, and a 16 A slow blow fuse is suggested for external overcurrent protection.

In terms of physical dimensions, the 785639-01 measures 7.8 in. × 3.0 in. × 1.9 in. and weighs 1.2 kg. It has a recommended calibration interval of 1 year. The device is designed to operate between -40 °C to 85 °C with relative humidity up to 100%. It can be stored in temperatures ranging from -40 °C to 100 °C. It is designed for operation at altitudes up to 5000 meters.

Part Number785639-01
Model NameFD-11603
Part TypeVoltage Input Device for FieldDAQ
Number of Analog Input Channels8
ADC Resolution24 bits
Analog Input Voltage Range±10.5 V
Timebase Frequency13.1072 MHz, 12.8 MHz, 12.288 MHz, and 10.24 MHz
Sample Rate500 samples/s to 102.4 kSamples/s
Maximum Device Power Consumption7.5 W
Device Input Voltage Range9 VDC to 30 VDC

  785639-01 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: 7I5639-01, 78R639-01, 78T639-01, 785U39-01, 7856E9-01

785639-01



Modular Systems > National Instruments > FieldDAQ

785639-01, 8 Channels, 24 Bits, FD-11603 Voltage Input Device
5/5 | 11 ratings

Call now for best pricing
1-800-915-6216

National Instruments 785639-01 Voltage Input Device for FieldDAQ

Part Number 785639-01 identifies the National Instruments FD-11603 Voltage Input Device for FieldDAQ. The 785639-01 features 8 analog input channels with galvanic isolation between the channels and the chassis. Likewise, the device has a Delta-sigma ADC with a resolution of 24 bits and analog prefiltering. The input channels support a voltage range of ±10.5 V. The timebase frequency can be configured to 13.1072 MHz, 12.8 MHz, 12.288 MHz, and 10.24 MHz, with an accuracy of ±30 ppm maximum. The sample rate ranges from a minimum of 500 samples/s to a maximum of 102.4 kSamples/s.

This 785639-01 supports TCP/IP and UDP protocols, using a variety of network ports: HTTP:80 (configuration only), TCP:3580; UDP:5353 (configuration only), TCP:5353 (configuration only); TCP:31415; UDP:7865 (configuration only), and UDP:8473 (configuration only). It has a default MTU size of 1500 bytes. Additionally, it has two internally-switched 8-pin X-coded M12 ports for Ethernet communication. The communication rates are auto-negotiated between 10/100/1000 Mbps. The maximum cabling distance is 100 meters per segment, with a maximum of 15 hops per line. Furthermore, it uses IEEE 802.1AS protocol for network synchronization over 1000 Base-TX interface.

The 785639-01 supports an input voltage range of 9 VDC to 30 VDC, with a maximum power consumption of 7.5 W. Both power input and output use a 5-pin L-coded male M12 connector. The recommended torque for M12 connectors is 0.6 Nm. The maximum current for the Power IN/OUT terminals is 10 A, and a 16 A slow blow fuse is suggested for external overcurrent protection.

In terms of physical dimensions, the 785639-01 measures 7.8 in. × 3.0 in. × 1.9 in. and weighs 1.2 kg. It has a recommended calibration interval of 1 year. The device is designed to operate between -40 °C to 85 °C with relative humidity up to 100%. It can be stored in temperatures ranging from -40 °C to 100 °C. It is designed for operation at altitudes up to 5000 meters.

Part Number785639-01
Model NameFD-11603
Part TypeVoltage Input Device for FieldDAQ
Number of Analog Input Channels8
ADC Resolution24 bits
Analog Input Voltage Range±10.5 V
Timebase Frequency13.1072 MHz, 12.8 MHz, 12.288 MHz, and 10.24 MHz
Sample Rate500 samples/s to 102.4 kSamples/s
Maximum Device Power Consumption7.5 W
Device Input Voltage Range9 VDC to 30 VDC

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn