785641-01, FieldDAQ, 8 Channel, FD-11637 Strain/Bridge Input Device
4.9/5 | 13 ratings
Fast Quote
Quoted Price

Need an Official Quote?

 

National Instruments 785641-01 Strain/Bridge Input Device for FieldDAQ

Part Number 785641-01 is the identifying part number for the National Instruments FD-11637 Strain/Bridge Input Device for FieldDAQ. The 785641-01 has 8 analog input channels and features galvanic isolation between channels and the chassis. The input range for the device is ±38 mV/V. Likewise, it features a delta-sigma ADC with a resolution of 24 bits and analog prefiltering. The sample mode is simultaneous and the timebase frequencies can take values of 13.1072 MHz, 12.8 MHz, 12.288 MHz, or 10.24 MHz with a maximum accuracy of ±30 ppm. The sampled data rate ranges from a minimum of 500 samples/s to a maximum of 102.4 ksamples/s. 

This 785641-01 supports TCP/IP and UDP protocols, using a variety of network ports: HTTP:80 (configuration only), TCP:3580; UDP:5353 (configuration only), TCP:5353 (configuration only); TCP:31415; UDP:7865 (configuration only), and UDP:8473 (configuration only). It has a default MTU size of 1500 bytes. Additionally, it has two internally-switched 8-pin X-coded M12 ports for Ethernet communication. The communication rates are auto-negotiated between 10/100/1000 Mbps. The maximum cabling distance is 100 meters per segment, with a maximum of 15 hops per line. 

The 785641-01 supports an input voltage range of 9 VDC to 30 VDC, with a maximum power consumption of 15 W and a maximum heat dissipation of 11 W. Both power input and output use a 5-pin L-coded male M12 connector. The recommended torque for M12 connectors is 0.6 Nm. The maximum current for the Power IN/OUT terminals is 10 A, and a 16 A slow blow fuse is suggested for external overcurrent protection.

In terms of physical dimensions, the 785641-01 measures 7.8 in. × 3.0 in. × 1.9 in. and weighs 1.2 kg. It has a recommended calibration interval of 1 year. The device is designed to operate between -40 °C to 85 °C with relative humidity up to 100%. It can be stored in temperatures ranging from -40 °C to 100 °C. It is designed for operation at altitudes up to 5000 meters.

Part Number785641-01
Model NameFD-11637
Part TypeStrain/Bridge Input Device for FieldDAQ
Number of Analog Input Channels8
ADC24-bit Delta-sigma ADC with analog prefiltering
Timebase Frequencies13.1072 MHz, 12.8 MHz, 12.288 MHz, or 10.24 MHz
Network ProtocolsTCP/IP, UDP
Ethernet Ports2 8-pin X-coded M12 ports, internally switched
Input Voltage Range9 VDC to 30 VDC
Maximum Device Power Consumption15 W

  785641-01 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: U85641-01, 78T641-01, 78Y641-01, 785T41-01, 7856T1-01

785641-01



Modular Systems > National Instruments > FieldDAQ

785641-01, FieldDAQ, 8 Channel, FD-11637 Strain/Bridge Input Device
4.9/5 | 13 ratings

Call now for best pricing
1-800-915-6216

National Instruments 785641-01 Strain/Bridge Input Device for FieldDAQ

Part Number 785641-01 is the identifying part number for the National Instruments FD-11637 Strain/Bridge Input Device for FieldDAQ. The 785641-01 has 8 analog input channels and features galvanic isolation between channels and the chassis. The input range for the device is ±38 mV/V. Likewise, it features a delta-sigma ADC with a resolution of 24 bits and analog prefiltering. The sample mode is simultaneous and the timebase frequencies can take values of 13.1072 MHz, 12.8 MHz, 12.288 MHz, or 10.24 MHz with a maximum accuracy of ±30 ppm. The sampled data rate ranges from a minimum of 500 samples/s to a maximum of 102.4 ksamples/s. 

This 785641-01 supports TCP/IP and UDP protocols, using a variety of network ports: HTTP:80 (configuration only), TCP:3580; UDP:5353 (configuration only), TCP:5353 (configuration only); TCP:31415; UDP:7865 (configuration only), and UDP:8473 (configuration only). It has a default MTU size of 1500 bytes. Additionally, it has two internally-switched 8-pin X-coded M12 ports for Ethernet communication. The communication rates are auto-negotiated between 10/100/1000 Mbps. The maximum cabling distance is 100 meters per segment, with a maximum of 15 hops per line. 

The 785641-01 supports an input voltage range of 9 VDC to 30 VDC, with a maximum power consumption of 15 W and a maximum heat dissipation of 11 W. Both power input and output use a 5-pin L-coded male M12 connector. The recommended torque for M12 connectors is 0.6 Nm. The maximum current for the Power IN/OUT terminals is 10 A, and a 16 A slow blow fuse is suggested for external overcurrent protection.

In terms of physical dimensions, the 785641-01 measures 7.8 in. × 3.0 in. × 1.9 in. and weighs 1.2 kg. It has a recommended calibration interval of 1 year. The device is designed to operate between -40 °C to 85 °C with relative humidity up to 100%. It can be stored in temperatures ranging from -40 °C to 100 °C. It is designed for operation at altitudes up to 5000 meters.

Part Number785641-01
Model NameFD-11637
Part TypeStrain/Bridge Input Device for FieldDAQ
Number of Analog Input Channels8
ADC24-bit Delta-sigma ADC with analog prefiltering
Timebase Frequencies13.1072 MHz, 12.8 MHz, 12.288 MHz, or 10.24 MHz
Network ProtocolsTCP/IP, UDP
Ethernet Ports2 8-pin X-coded M12 ports, internally switched
Input Voltage Range9 VDC to 30 VDC
Maximum Device Power Consumption15 W

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn