National Instruments FD-11613 Temperature Input Device for FieldDAQ
The FD-11613 is a Temperature Input Device. The NI FD-11613 device is created by National Instruments. The part number for the Temperature Input Device is 785640-01. The FD-11613 is operated and programmed with the NI-DAQmx driver software. The NI FD-11613 is installed on Windows operating systems. The FD-11613 comes with thermocouple channels for enabling temperature inputs. The NI FD-11613 Temperature Input Device is designed for cold junction compensating.
The National Instruments FD-11613 Temperature Input Device is manufactured for the FieldDAQ platform. The FD-11613 device comes with a maximum of 8 thermocouple channels. The NI FD-11613 is featured with open thermocouple detection. The module of an LED is offered at each channel of the FD-11613 device that identifies disconnected thermocouples. The NI FD-11613 Temperature Input Device is available with dust and water resistance capabilities, since it is rated with an ingress protection of IP67. The major advantage of the FD-11613 device is that it can bear the shock up to 100 g. The vibration of 10 g is supported by the NI FD-11613.
The NI FD-11613 Temperature Input Device is delivered with Time-Sensitive Networking functionality. The FD-11613 is incorporated with a network switch that is used for controlling the network connections. The National Instruments FD-11613 Temperature Input Device can perform simple daisy-chaining based on the internal architecture power circuitry. The NI FD-11613 is used within a temperature range of -40 to 85 °C for device operations. The FD-11613 can easily be synchronized with various FieldDAQ devices.
Model | FD-11613 |
---|---|
Manufacturer | National Instruments |
Part Number | 785640-01 |
Type | Temperature Input Device for FieldDAQ |
Channels | 8 isolated thermocouple channels, 2 CJC |
ADC Resolution | 24 bits |
Type of ADC | Delta-Sigma |
Voltage Input Range | 9 V DC to 30 V DC |
Maximum Device Power Consumption | 4.9 W |
Dimensions | 7.8 in. × 3.0 in. × 1.9 in. |
Weight | 40 oz. |
Warranty | 2-3 Year Warranty |
FD-11613 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the FD-11613:
143886A-01L, 143886B-01L, 143886C-01L, 143886D-01L, 143886E-01L, 144843A-01L, 144843B-01L, 144843C-01L, 144948A-01L, 144948B-01L, 144948C-01L, 145229A-01L, 145229B-01L, 785640-01
FD-11613 PDF Manuals
FD-11613 11614 CALIBRATION PROCEDURE.PDF
FD-11613 11614 QUICK START.PDF
FD-11613 FD 11614 LETTER OF VOLATILITY.PDF
FD-11613 SAFETY ENVIRONMENTAL AND REGULATORY INFORMATION.PDF
CDAQ 9185 9189 AND FIELDDAQ FOSS RELEASE NOTES 28VERSION 18.629.PDF
CDAQ 9185 9189 AND FIELDDAQ FOSS RELEASE NOTES 28VERSION 19.129.PDF
CDAQ 9185 9189 AND FIELDDAQ FOSS RELEASE NOTES 28VERSION 19.529.PDF
Driver Downloads for FD-11613
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
FD-11613
Modular Systems > National Instruments > FieldDAQ
FD-11613, 8 Thermocouple Channels, Temperature Input Device for FieldDAQ
1-800-915-6216
- Description
- Technical Specifications
- Manuals & PDFs
- Drivers
National Instruments FD-11613 Temperature Input Device for FieldDAQ
The FD-11613 is a Temperature Input Device. The NI FD-11613 device is created by National Instruments. The part number for the Temperature Input Device is 785640-01. The FD-11613 is operated and programmed with the NI-DAQmx driver software. The NI FD-11613 is installed on Windows operating systems. The FD-11613 comes with thermocouple channels for enabling temperature inputs. The NI FD-11613 Temperature Input Device is designed for cold junction compensating.
The National Instruments FD-11613 Temperature Input Device is manufactured for the FieldDAQ platform. The FD-11613 device comes with a maximum of 8 thermocouple channels. The NI FD-11613 is featured with open thermocouple detection. The module of an LED is offered at each channel of the FD-11613 device that identifies disconnected thermocouples. The NI FD-11613 Temperature Input Device is available with dust and water resistance capabilities, since it is rated with an ingress protection of IP67. The major advantage of the FD-11613 device is that it can bear the shock up to 100 g. The vibration of 10 g is supported by the NI FD-11613.
The NI FD-11613 Temperature Input Device is delivered with Time-Sensitive Networking functionality. The FD-11613 is incorporated with a network switch that is used for controlling the network connections. The National Instruments FD-11613 Temperature Input Device can perform simple daisy-chaining based on the internal architecture power circuitry. The NI FD-11613 is used within a temperature range of -40 to 85 °C for device operations. The FD-11613 can easily be synchronized with various FieldDAQ devices.
Model | FD-11613 |
---|---|
Manufacturer | National Instruments |
Part Number | 785640-01 |
Type | Temperature Input Device for FieldDAQ |
Channels | 8 isolated thermocouple channels, 2 CJC |
ADC Resolution | 24 bits |
Type of ADC | Delta-Sigma |
Voltage Input Range | 9 V DC to 30 V DC |
Maximum Device Power Consumption | 4.9 W |
Dimensions | 7.8 in. × 3.0 in. × 1.9 in. |
Weight | 40 oz. |
Warranty | 2-3 Year Warranty |
FD-11613 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
FD-11613 PDF Manuals & Diagrams
FD-11613 PDF Manuals
FD-11613 11614 CALIBRATION PROCEDURE.PDF
FD-11613 11614 QUICK START.PDF
FD-11613 FD 11614 LETTER OF VOLATILITY.PDF
FD-11613 SAFETY ENVIRONMENTAL AND REGULATORY INFORMATION.PDF
CDAQ 9185 9189 AND FIELDDAQ FOSS RELEASE NOTES 28VERSION 18.629.PDF
CDAQ 9185 9189 AND FIELDDAQ FOSS RELEASE NOTES 28VERSION 19.129.PDF
CDAQ 9185 9189 AND FIELDDAQ FOSS RELEASE NOTES 28VERSION 19.529.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."