Modular Systems > National Instruments > FieldPoint




Or speak to a sales representative for additional information:
FP-AI-112 In Stock | Ships Today
FP-AI-112, 16-Channel, 16-bit, Analog Input Module
Need an Official Quote?
National Instruments FP-AI-112 Analog Input Module
Featured with 50/60 Hz filter settings, 8 Voltage input ranges, and 16-bits resolution, the NI FP-AI-112 (Part Number: 777518-112) is a FieldPoint compatible Analog Input Module. This hot-swappable module offers up to 250 Vrms continuous isolation on a channel-to-ground basis and can be operated within a wide temperature range of –40 to 70 °C.
The NI FP-AI-112 is designed to measure unipolar and bipolar signals within a range of 60 mV to 10 V. This module offers configurable filtration and eight input ranges on a per channel basis. This module does not require an external power supply, since it takes the required power from its host FieldPoint terminal base. Moreover, the user can plug in or unplug the module without causing any disruption.
The NI FP-AI-112 can be considered for a broad range of applications because it is a versatile module. This Analog Input Module can measure 4 to 20 mA current loops coming from standard industrial transmitters and sensors. With this module, the user can step directly from their industrial sensors or other devices under test. This arrangement ensures hassle-free, high-accuracy measurements.
The FP-AI-112 comes with a POWER (green) LED indicator to show when the power is ON and the unit has passed self-tests. Another LED indicator READY (green) is also provided to communicate that the module is correctly configured and is ready as well. The National Instruments FP-AI-112 requires about 350 mW of power. The necessary power to the module is provided from the network module.
Model | FP-AI-112 |
---|---|
Manufacturer | National Instruments |
Part Number | 777518-112 |
Type | Analog Input Module |
Channels | 16 |
Resolution | 16-bit |
Operating Temperature Range | –40 to 70 °C |
Type of ADC | Delta-sigma |
Weight | 5.0 oz. |
Warranty | 2-3 Year Warranty |
FP-AI-112 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the FP-AI-112:
188494A-01, 191020A-01, 777518-112
National Instruments FP-AI-112 Frequently Asked Questions
Question: What is the overvoltage protection of the FP-AI-112 module?
Answer: The overvoltage protection of the FP-AI-112 module is ±40 V.
Question: What is the input impedance of the NI FP-AI-112 with the power on?
Answer: The input impedance of the NI FP-AI-112 with the power on is >100 MΩ.
Question: What is the continuous channel-to-ground isolation of the FP-AI-112?
Answer: The continuous channel-to-ground isolation of the FP-AI-112 is 250 Vrms, Installation Category II.
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
FP-AI-112
Modular Systems > National Instruments > FieldPoint
FP-AI-112, 16-Channel, 16-bit, Analog Input Module
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments FP-AI-112 Analog Input Module
Featured with 50/60 Hz filter settings, 8 Voltage input ranges, and 16-bits resolution, the NI FP-AI-112 (Part Number: 777518-112) is a FieldPoint compatible Analog Input Module. This hot-swappable module offers up to 250 Vrms continuous isolation on a channel-to-ground basis and can be operated within a wide temperature range of –40 to 70 °C.
The NI FP-AI-112 is designed to measure unipolar and bipolar signals within a range of 60 mV to 10 V. This module offers configurable filtration and eight input ranges on a per channel basis. This module does not require an external power supply, since it takes the required power from its host FieldPoint terminal base. Moreover, the user can plug in or unplug the module without causing any disruption.
The NI FP-AI-112 can be considered for a broad range of applications because it is a versatile module. This Analog Input Module can measure 4 to 20 mA current loops coming from standard industrial transmitters and sensors. With this module, the user can step directly from their industrial sensors or other devices under test. This arrangement ensures hassle-free, high-accuracy measurements.
The FP-AI-112 comes with a POWER (green) LED indicator to show when the power is ON and the unit has passed self-tests. Another LED indicator READY (green) is also provided to communicate that the module is correctly configured and is ready as well. The National Instruments FP-AI-112 requires about 350 mW of power. The necessary power to the module is provided from the network module.
Model | FP-AI-112 |
---|---|
Manufacturer | National Instruments |
Part Number | 777518-112 |
Type | Analog Input Module |
Channels | 16 |
Resolution | 16-bit |
Operating Temperature Range | –40 to 70 °C |
Type of ADC | Delta-sigma |
Weight | 5.0 oz. |
Warranty | 2-3 Year Warranty |
FP-AI-112 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments FP-AI-112 Frequently Asked Questions
Question: What is the overvoltage protection of the FP-AI-112 module?
Answer: The overvoltage protection of the FP-AI-112 module is ±40 V.
Question: What is the input impedance of the NI FP-AI-112 with the power on?
Answer: The input impedance of the NI FP-AI-112 with the power on is >100 MΩ.
Question: What is the continuous channel-to-ground isolation of the FP-AI-112?
Answer: The continuous channel-to-ground isolation of the FP-AI-112 is 250 Vrms, Installation Category II.
FP-AI-112 PDF Manuals & Diagrams
FP-AI-112 PDF Manuals
FP-AI-112 AND CFP-AI-112 OPERATING INSTRUCTIONS.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."