SH96F-96M-42V, National Instruments, 60 VDC, Shielded Cable
Need an Official Quote?
National Instruments SH96F-96M-42V Shielded Cable
The shielded cable SH96F-96M-42V (Part Numbers: 158228-01, 158228-03, 158228-05) from National Instruments is intended to be used with the PXIe-4304/5 to Rackmount Terminal Block. It has a 60 VDC maximum operating voltage that can be applied to any pin to any pin.
There are 24 pairs of wires in the cable: pairs 1 through 20 are shielded-twisted pairs of 28 AWG, pairs 21 and 22 are shielded-twisted pairs of 22 AWG, and pairings 22 through 24 are shielded-twisted pairs of 28 AWG. For the outside shield, the shielding consists of braid with 85% coverage and foil for the inner shield. The cable comes in lengths of 1 meter, 3 meter, and 5 meter, with corresponding weights of 1,187 g, 2,040 g, and 2,894 g for each length.
It is equipped with 96-pin Type R DIN 41612/IEC 60603-2 male and female connectors. It operates between 0°C and 55°C in the ambient temperature range, meeting the MIL-PRF-28800F Class 2 high temperature limit and Class 3 low temperature limit. With a maximum altitude of 2,000 meters and a Pollution Degree of 2, the cable is appropriate for indoor use. For storage, the ambient temperature range is -40°C to 71°C, with a relative humidity range of 5% to 95%, noncondensing.
It withstands operating shocks up to 30g peak, half-sine, 11ms pulse, and random vibrations in the range of 5 Hz to 500 Hz, 0.3g rms during operation, and 2.4g rms in non-operating conditions. Safety compliance includes IEC 61010-1, EN 61010-1, UL 61010-1, and CSA 61010-1 standards for electrical equipment used in measurement, control, and laboratory environments.
Model Name | SH96F-96M-42V |
---|---|
Part Number(s) | 158228-01, 158228-03, 158228-05 |
Manufacturer | National Instruments |
Maximum Working Voltage | 60 VDC |
Cable Wire Gauge | 28 AWG (pairs 1-20), 22 AWG (pair 21), 28 AWG (pairs 22-24) |
Shielding | Foil (Inner), Braid (Outer, 85% coverage) |
Connector Type | Male and Female, 96-pin Type R DIN 41612/IEC 60603-2 |
Available Lengths | 1m (3.3 ft), 3m (9.8 ft), 5m (16.4 ft) |
Weight | 1m - 1,187g (42.2 oz), 3m - 2,040g (72.6 oz), 5m - 2,894g (102.1 oz) |
Operating Temperature Range | 0°C to 55°C |
Relative Humidity Range | 10% to 90%, noncondensing |
Storage Temperature Range | -40°C to 71°C |
Storage Humidity Range | 5% to 95%, noncondensing |
Operating Shock | 30g peak, half-sine, 11ms pulse |
National Instruments SH96F-96M-42V Frequently Asked Questions
Question: What is the function of the SH96F-96M-42V model?
Answer: The cable provides connectivity for Switch block modules.
Question: What connectors does SH96F-96M-42V have?
Answer: 96-pin Type R DIN 41612/IEC 60603-2 male and female connectors.
Question: How many wires does the SH96F-96M-42V cable contain?
Answer: There are 24 pairs of wires in the SH96F-96M-42V cable: pairs 1 through 20 are shielded-twisted pairs of 28 AWG, pairs 21 and 22 are shielded-twisted pairs of 22 AWG, and pairings 22 through 24 are shielded-twisted pairs of 28 AWG.
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
SH96F-96M-42V
Modular Systems > National Instruments > NI Cables
SH96F-96M-42V, National Instruments, 60 VDC, Shielded Cable
1-800-915-6216
- Description
- Technical Specifications
- Frequently Asked Questions
- Manuals & PDFs
National Instruments SH96F-96M-42V Shielded Cable
The shielded cable SH96F-96M-42V (Part Numbers: 158228-01, 158228-03, 158228-05) from National Instruments is intended to be used with the PXIe-4304/5 to Rackmount Terminal Block. It has a 60 VDC maximum operating voltage that can be applied to any pin to any pin.
There are 24 pairs of wires in the cable: pairs 1 through 20 are shielded-twisted pairs of 28 AWG, pairs 21 and 22 are shielded-twisted pairs of 22 AWG, and pairings 22 through 24 are shielded-twisted pairs of 28 AWG. For the outside shield, the shielding consists of braid with 85% coverage and foil for the inner shield. The cable comes in lengths of 1 meter, 3 meter, and 5 meter, with corresponding weights of 1,187 g, 2,040 g, and 2,894 g for each length.
It is equipped with 96-pin Type R DIN 41612/IEC 60603-2 male and female connectors. It operates between 0°C and 55°C in the ambient temperature range, meeting the MIL-PRF-28800F Class 2 high temperature limit and Class 3 low temperature limit. With a maximum altitude of 2,000 meters and a Pollution Degree of 2, the cable is appropriate for indoor use. For storage, the ambient temperature range is -40°C to 71°C, with a relative humidity range of 5% to 95%, noncondensing.
It withstands operating shocks up to 30g peak, half-sine, 11ms pulse, and random vibrations in the range of 5 Hz to 500 Hz, 0.3g rms during operation, and 2.4g rms in non-operating conditions. Safety compliance includes IEC 61010-1, EN 61010-1, UL 61010-1, and CSA 61010-1 standards for electrical equipment used in measurement, control, and laboratory environments.
Model Name | SH96F-96M-42V |
---|---|
Part Number(s) | 158228-01, 158228-03, 158228-05 |
Manufacturer | National Instruments |
Maximum Working Voltage | 60 VDC |
Cable Wire Gauge | 28 AWG (pairs 1-20), 22 AWG (pair 21), 28 AWG (pairs 22-24) |
Shielding | Foil (Inner), Braid (Outer, 85% coverage) |
Connector Type | Male and Female, 96-pin Type R DIN 41612/IEC 60603-2 |
Available Lengths | 1m (3.3 ft), 3m (9.8 ft), 5m (16.4 ft) |
Weight | 1m - 1,187g (42.2 oz), 3m - 2,040g (72.6 oz), 5m - 2,894g (102.1 oz) |
Operating Temperature Range | 0°C to 55°C |
Relative Humidity Range | 10% to 90%, noncondensing |
Storage Temperature Range | -40°C to 71°C |
Storage Humidity Range | 5% to 95%, noncondensing |
Operating Shock | 30g peak, half-sine, 11ms pulse |
National Instruments SH96F-96M-42V Frequently Asked Questions
Question: What is the function of the SH96F-96M-42V model?
Answer: The cable provides connectivity for Switch block modules.
Question: What connectors does SH96F-96M-42V have?
Answer: 96-pin Type R DIN 41612/IEC 60603-2 male and female connectors.
Question: How many wires does the SH96F-96M-42V cable contain?
Answer: There are 24 pairs of wires in the SH96F-96M-42V cable: pairs 1 through 20 are shielded-twisted pairs of 28 AWG, pairs 21 and 22 are shielded-twisted pairs of 22 AWG, and pairings 22 through 24 are shielded-twisted pairs of 28 AWG.
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."