781094-01, Spring-Clamp Terminals, 24 VDC, 10 A, PS-16 Power Supply
4.7/5 | 11 ratings
Fast Quote
Quoted Price

Need an Official Quote?

 

National Instruments  781094-01 Industrial Power Supply

Part Number 781094-01 is the identifying part number for the National Instruments PS-16 Industrial Power Supply. The AC input voltages that can be applied to the 781094-01 lie in the rated ranges of 90 to 132 VAC or 180 to 264 VAC while DC input is not allowed. On the other hand, it can generate a guaranteed minimum output voltage of 24 to 28 V (nominal output is 24 V) whereas the maximum can reach up to 30V.

The nominal output current depends on the output voltage and the operating conditions: 12 A at 24V and < 45 °C, 10 A at 24V and < 60 °C, 10.3 A at 28V and < 45 °C and 8.6 A at 28 V and < 60 °C. The nominal output power is 288 W at < 45 °C and 240 W at < 60 °C. 

The 781094-01 can be operated in a serial, parallel, or two-phase configuration. When operated in a serial configuration, the output voltage increases. You can connect several units in series as long as the sum of output voltage does not exceed 150 VDC. On the other hand, parallel configuration guarantees better system availability ensuring normal operation even if one of the units fails. However, tracing failure can be challenging as the status LED still stays ON due to the power from another unit. It is recommended to use separate input fuses for each power supply and to connect each power supply to different phases or circuits whenever possible. Lastly, when used in two-phase power mode, a fuse or a circuit breaker must be used to protect the neutral input, and the phase-to-phase connection is only allowed when the supply voltage is less than 240V + 10%.

The 781094-01 measures 60 x 124 x 117 mm in physical dimensions and weighs 700g. The recommended temperature range for the operation of the module is –25 °C to +70 °C. Likewise, it can be stored at a much wider range of –40 to +85 °C. Likewise, the recommended humidity levels lie between 5 to 95% r. H. while the recommended altitude ranges between 0 to 6000m.

Part Number781094-01
Model NamePS-16
Part TypeIndustrial Power Supply
Output Voltage24 to 28 V (30V maximum)
Output Current12 A at 24V and < 45 °C,
10 A at 24V and < 60 °C,
10.3 A at 28V and < 45 °C,
8.6 A at 28 V and < 60 °C
Output Power288 W at < 45 °C,
240 W at < 60 °C
Input AC Voltage90 to 132 VAC or 180 to 264 VAC
Input Frequency50 to 60 Hz
Short-Circuit Current14 A (minimum),
18 A (maximum)
Operating Temperature–25 °C to +70 °C

  781094-01 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: 7O1094-01, 78Q094-01, 781O94-01, 781P94-01, 7810O4-01

781094-01



Modular Systems > National Instruments > NI Power Supplies

781094-01, Spring-Clamp Terminals, 24 VDC, 10 A, PS-16 Power Supply
4.7/5 | 11 ratings

Call now for best pricing
1-800-915-6216

National Instruments  781094-01 Industrial Power Supply

Part Number 781094-01 is the identifying part number for the National Instruments PS-16 Industrial Power Supply. The AC input voltages that can be applied to the 781094-01 lie in the rated ranges of 90 to 132 VAC or 180 to 264 VAC while DC input is not allowed. On the other hand, it can generate a guaranteed minimum output voltage of 24 to 28 V (nominal output is 24 V) whereas the maximum can reach up to 30V.

The nominal output current depends on the output voltage and the operating conditions: 12 A at 24V and < 45 °C, 10 A at 24V and < 60 °C, 10.3 A at 28V and < 45 °C and 8.6 A at 28 V and < 60 °C. The nominal output power is 288 W at < 45 °C and 240 W at < 60 °C. 

The 781094-01 can be operated in a serial, parallel, or two-phase configuration. When operated in a serial configuration, the output voltage increases. You can connect several units in series as long as the sum of output voltage does not exceed 150 VDC. On the other hand, parallel configuration guarantees better system availability ensuring normal operation even if one of the units fails. However, tracing failure can be challenging as the status LED still stays ON due to the power from another unit. It is recommended to use separate input fuses for each power supply and to connect each power supply to different phases or circuits whenever possible. Lastly, when used in two-phase power mode, a fuse or a circuit breaker must be used to protect the neutral input, and the phase-to-phase connection is only allowed when the supply voltage is less than 240V + 10%.

The 781094-01 measures 60 x 124 x 117 mm in physical dimensions and weighs 700g. The recommended temperature range for the operation of the module is –25 °C to +70 °C. Likewise, it can be stored at a much wider range of –40 to +85 °C. Likewise, the recommended humidity levels lie between 5 to 95% r. H. while the recommended altitude ranges between 0 to 6000m.

Part Number781094-01
Model NamePS-16
Part TypeIndustrial Power Supply
Output Voltage24 to 28 V (30V maximum)
Output Current12 A at 24V and < 45 °C,
10 A at 24V and < 60 °C,
10.3 A at 28V and < 45 °C,
8.6 A at 28 V and < 60 °C
Output Power288 W at < 45 °C,
240 W at < 60 °C
Input AC Voltage90 to 132 VAC or 180 to 264 VAC
Input Frequency50 to 60 Hz
Short-Circuit Current14 A (minimum),
18 A (maximum)
Operating Temperature–25 °C to +70 °C

781094-01 PDF Manuals & Diagrams

  781094-01 PDF Manuals

NI PS 16 POWER SUPPLY USER MANUAL AND SPECIFICATIONS.PDF


Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn