PXI-4110 National Instruments Programmable Power Supply | Apex Waves | ImagePXI-4110 National Instruments Programmable Power Supply | Apex Waves | ImageNI-PXI-4110 NewNI-PXI-4110 | Legacy, Refurbished and New Surplus
PXI-4110 National Instruments Programmable Power Supply | Apex Waves | Image
PXI-4110 National Instruments Programmable Power Supply | Apex Waves | Image
NI-PXI-4110 New
NI-PXI-4110 | Legacy, Refurbished and New Surplus

NI-PXI-4110

4.5/5 | 7 ratings

Modular Systems > National Instruments > NI Power Supplies

Part Number NI-PXI-4110
Manufacturer/Brand National Instruments
Description: NI-PXI-4110, 3 Output Channels, Single Quadrant, 11 to 15.5 VDC, PXI Programmable Power Supply
In Stock | Ships Today
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments NI-PXI-4110 PXI Programmable Power Supply

National Instruments' programmable DC power supply, the PXI-4110 (Part Numbers: 779647-11, 779647-10), is an adaptable instrument for use in manufacturing test and design validation applications. This single-quadrant power supply provides great flexibility with two isolated and one non-isolated supply channel, each able to give up to 1 A. Part number 779647-10 represents the standard version of the PXI-4110, while part number 779647-11 describes the version of the power supply that is equipped with NI APS-4100 Auxiliary Power.

Users can precisely control voltage setpoints and current limits while also accessing voltage and current measurement functionalities. Additionally, channels can be combined to produce more voltage or current.

With regard to regulation, the PXI-4110 has outstanding capabilities for both load and line regulation. Line regulation is 0.01% plus 1 mV for each volt of change in auxiliary power input across channels 1 and 2, and 0.01% plus 0.02% of range for current regulation. Depending on the channel, voltage load regulation varies from 0.1% to 0.42% per amp of output load, while current load regulation varies from 0.003% to 0.02% per volt of output variation.

The device's transient reaction is quick; it takes 50 μs for it to recover to within 0.1% of the voltage range following a shift in load current from 50% to 100% of the current range.

Along with ensuring security, the PXI-4110 has a number of protection mechanisms. Overvoltage, overcurrent, reverse voltage, and overtemperature protection is provided for the output channels. The protection against overvoltage and overcurrent for the auxiliary power input is identical.

An interval of one year is advised for calibrating reasons. Typically, PXI power usage is 1 W for 3.3 V, 6 W for 12 V, 3 W for -12 V, and 10 W for 5 V. These are comparatively low power requirements. 11 VDC to 15.5 VDC, with a maximum of 5 A, is the input range required for an optional auxiliary power source.

With its dimensions of 2.0 cm × 13.0 cm × 21.6 cm and weight of 323 g, the PXI-4110 is physically small, fitting into a 3U, one-slot PXI/cPCI module.

The operating environment standards span from -40°C to 71°C with a relative humidity range of 5% to 95%, while the ambient temperature range is 0°C to 55°C with a relative humidity range of 10% to 90%. 

ModelNIPXI-4110
Part Numbers779647-10 and 779647-11
ManufacturerNational Instruments
HTS Code8504406001
TypePXI Programmable Power Supply
Channels3
Total Output Power9 W or 46 W
Analog Output Voltage Range-20 V to 20 V
Dimension8.5 x 5.1 x 0.8 in.
Weight323 g.
WarrantyThree Year Warranty
PXI-4110 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments NI-PXI-4110 Frequently Asked Questions

 

Question: What are the differences between the two part numbers for the National Instruments NI PXI-4110?

Answer: Part number 779647-10 has 9 W total output power and does not include auxiliary power. Part number 779647-11 has 46 W total output power and includes auxiliary power.

 

Question: How long is the PXI 4110 calibration interval?

Answer: The PXI-4110 calibration interval is one year.

 

Question: What type is the PXI-4110 connector?

Answer: The PXI-4110 connector is MINI-COMBICON, 3.81 mm (6 position), nominal for the output channels and MINI-COMBICON, 3.5 mm (2 position), nominal for the auxiliary power input.

 

Question: What is the PXI-4110 driver software called?

Answer: The PXI-4110 driver software is called NI-DCPower Instrument Driver.

 

Question: What is the PXI-4110 Power Supply source?

Answer: The PXI-4110 Power Supply source is externally powered, internally powered.

 

Question: Should I use a breakout box for voltage load regulation of the PXI-4110?

Answer: Instead of a using a breakout box, the load can be connected at the connector using the connector shell kit or the screw terminals.

 

Question: What is the current limit for the PXI-4110?

Answer: The PXI-4110 has a current limit that is set to 1A for auxiliary power and 100 mA for internal power.


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: GI-PXI-4110, NI-PDI-4110, NI-PXU-4110, NI-PXL-4110, NI-PXI-4Q10

NI-PXI-4110



Modular Systems > National Instruments > NI Power Supplies

NI-PXI-4110
4.5/5 | 7 ratings

NI-PXI-4110, 3 Output Channels, Single Quadrant, 11 to 15.5 VDC, PXI Programmable Power Supply

In Stock | Ships Today
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments NI-PXI-4110 PXI Programmable Power Supply

National Instruments' programmable DC power supply, the PXI-4110 (Part Numbers: 779647-11, 779647-10), is an adaptable instrument for use in manufacturing test and design validation applications. This single-quadrant power supply provides great flexibility with two isolated and one non-isolated supply channel, each able to give up to 1 A. Part number 779647-10 represents the standard version of the PXI-4110, while part number 779647-11 describes the version of the power supply that is equipped with NI APS-4100 Auxiliary Power.

Users can precisely control voltage setpoints and current limits while also accessing voltage and current measurement functionalities. Additionally, channels can be combined to produce more voltage or current.

With regard to regulation, the PXI-4110 has outstanding capabilities for both load and line regulation. Line regulation is 0.01% plus 1 mV for each volt of change in auxiliary power input across channels 1 and 2, and 0.01% plus 0.02% of range for current regulation. Depending on the channel, voltage load regulation varies from 0.1% to 0.42% per amp of output load, while current load regulation varies from 0.003% to 0.02% per volt of output variation.

The device's transient reaction is quick; it takes 50 μs for it to recover to within 0.1% of the voltage range following a shift in load current from 50% to 100% of the current range.

Along with ensuring security, the PXI-4110 has a number of protection mechanisms. Overvoltage, overcurrent, reverse voltage, and overtemperature protection is provided for the output channels. The protection against overvoltage and overcurrent for the auxiliary power input is identical.

An interval of one year is advised for calibrating reasons. Typically, PXI power usage is 1 W for 3.3 V, 6 W for 12 V, 3 W for -12 V, and 10 W for 5 V. These are comparatively low power requirements. 11 VDC to 15.5 VDC, with a maximum of 5 A, is the input range required for an optional auxiliary power source.

With its dimensions of 2.0 cm × 13.0 cm × 21.6 cm and weight of 323 g, the PXI-4110 is physically small, fitting into a 3U, one-slot PXI/cPCI module.

The operating environment standards span from -40°C to 71°C with a relative humidity range of 5% to 95%, while the ambient temperature range is 0°C to 55°C with a relative humidity range of 10% to 90%. 

ModelNIPXI-4110
Part Numbers779647-10 and 779647-11
ManufacturerNational Instruments
HTS Code8504406001
TypePXI Programmable Power Supply
Channels3
Total Output Power9 W or 46 W
Analog Output Voltage Range-20 V to 20 V
Dimension8.5 x 5.1 x 0.8 in.
Weight323 g.
WarrantyThree Year Warranty
PXI-4110 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments NI-PXI-4110 Frequently Asked Questions

 

Question: What are the differences between the two part numbers for the National Instruments NI PXI-4110?

Answer: Part number 779647-10 has 9 W total output power and does not include auxiliary power. Part number 779647-11 has 46 W total output power and includes auxiliary power.

 

Question: How long is the PXI 4110 calibration interval?

Answer: The PXI-4110 calibration interval is one year.

 

Question: What type is the PXI-4110 connector?

Answer: The PXI-4110 connector is MINI-COMBICON, 3.81 mm (6 position), nominal for the output channels and MINI-COMBICON, 3.5 mm (2 position), nominal for the auxiliary power input.

 

Question: What is the PXI-4110 driver software called?

Answer: The PXI-4110 driver software is called NI-DCPower Instrument Driver.

 

Question: What is the PXI-4110 Power Supply source?

Answer: The PXI-4110 Power Supply source is externally powered, internally powered.

 

Question: Should I use a breakout box for voltage load regulation of the PXI-4110?

Answer: Instead of a using a breakout box, the load can be connected at the connector using the connector shell kit or the screw terminals.

 

Question: What is the current limit for the PXI-4110?

Answer: The PXI-4110 has a current limit that is set to 1A for auxiliary power and 100 mA for internal power.

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn