Modular Systems > National Instruments > PCI CAN Interfaces




Or speak to a sales representative for additional information:
PCI-CAN-LS2 Request for Availablility
PCI-CAN/LS2, 2-Port, Low-Speed/Fault-Tolerant, CAN Interface Device
Need an Official Quote?
National Instruments PCI-CAN/LS2 CAN Interface Device
The PCI-CAN/LS2 (Part number: 778007-02) is a low-speed/fault-tolerant CAN Interface Device from National Instruments. The instrument comes with two ports. The NI PCI CAN LS2 device has a built-in tolerance capability against faults. This feature helps the user carry out accurate measurements. The instrument also has a TJA1054A transceiver. The transceiver is highly tolerant towards faults. This further enables the device’s implementation in the development of applications for CAN. The maximum data transfer rate of the device is 125 kb per second. The instrument operates on DC voltage. The voltage and current ratings are +5 Volts and 900 mili-amperes.
The NI PCI-CAN/LS2 CAN Interface Device comes with NI-CAN driver software, which enables the integration of the module quickly. The instrument also offers separate connectors for each of the two channels. These I/O connectors are male DB9 connectors. These are designed in accordance with the recommendation of GiA DS 102. This CAN Interface Device additionally offers real-time support for LabVIEW, further extending the operational capabilities. This feature also enables the user to receive maximum benefits from the device.
The NI PCI-CAN/LS2 CAN Interface Device is a reliable instrument with sustained performance capabilities in tough environments. The range of relative humidity for the device’s normal operation has the value from 5% to 95%. This value is given for a non-condensing environment. The NI PCI-CAN/LS2 CAN Interface Device is strictly verified for noise emissions since this device fully complies to the FCC Class A specifications. The dimensions of this model are 8.15 x 4.4 inches.
Model | PCI-CAN/LS2 |
---|---|
Manufacturer | National Instruments |
Part Number | 778007-02 |
Type | CAN Interface Device |
Microprocessor | Intel 80386EX |
Ports | 2 |
Transceiver | TJA1054A |
Interface Type | ISO 11898 |
Maximum Baud Rate | 125 Kb/sec |
Minimum Baud Rate | 5 Kbps |
I/O Connector | 9-pin male D-SUB |
CAN_H, CAN_L Bus Lines | –27 to +40 VDC |
Isolation | Optical Isolation up to 500 V |
Power Requirements | + 5 VDC -- 900 mA |
Dimensions | 8.150 in. by 6.9 in. |
Software Driver | NI-CAN |
Warranty | 2-3 Year Warranty |
PCI-CAN/LS2 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PCI-CAN/LS2 Frequently Asked Questions
Question: Why can’t I find the PCI-CAN/LS2 anymore?
Answer: National Instruments has renamed the PCI-CAN/LS2. It is now the PCI-CAN.
Question: Can the NI PCI-CAN/LS2 communicate with a High-Speed device?
Answer: The NI PCI-CAN/LS2 cannot communicate with a high-speed device. The LS2 CAN card is a low-speed device that only communicates with other low-speed devices.
Question: What software does the PCI-CAN/LS2 come with?
Answer: The PCI-CAN/LS2 comes with NI-CAN driver software, a frame-based API.
PCI-CAN-LS2 PDF Manuals
ARCHIVED GETTING STARTED WITH YOUR CAN HARDWARE AND THE NI CAN SOFTWARE FOR WINDOWS 98 95.PDF
ARCHIVED GETTING STARTED WITH YOUR CAN HARDWARE AND THE NI CAN SOFTWARE FOR WINDOWS NT.PDF
ARCHIVED NI CAN USER MANUAL.PDF
NI CAN HARDWARE AND SOFTWARE MANUAL.PDF
NI DNET USER MANUAL AND SPECIFICATIONS.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PCI-CAN-LS2
Modular Systems > National Instruments > PCI CAN Interfaces
PCI-CAN/LS2, 2-Port, Low-Speed/Fault-Tolerant, CAN Interface Device
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments PCI-CAN/LS2 CAN Interface Device
The PCI-CAN/LS2 (Part number: 778007-02) is a low-speed/fault-tolerant CAN Interface Device from National Instruments. The instrument comes with two ports. The NI PCI CAN LS2 device has a built-in tolerance capability against faults. This feature helps the user carry out accurate measurements. The instrument also has a TJA1054A transceiver. The transceiver is highly tolerant towards faults. This further enables the device’s implementation in the development of applications for CAN. The maximum data transfer rate of the device is 125 kb per second. The instrument operates on DC voltage. The voltage and current ratings are +5 Volts and 900 mili-amperes.
The NI PCI-CAN/LS2 CAN Interface Device comes with NI-CAN driver software, which enables the integration of the module quickly. The instrument also offers separate connectors for each of the two channels. These I/O connectors are male DB9 connectors. These are designed in accordance with the recommendation of GiA DS 102. This CAN Interface Device additionally offers real-time support for LabVIEW, further extending the operational capabilities. This feature also enables the user to receive maximum benefits from the device.
The NI PCI-CAN/LS2 CAN Interface Device is a reliable instrument with sustained performance capabilities in tough environments. The range of relative humidity for the device’s normal operation has the value from 5% to 95%. This value is given for a non-condensing environment. The NI PCI-CAN/LS2 CAN Interface Device is strictly verified for noise emissions since this device fully complies to the FCC Class A specifications. The dimensions of this model are 8.15 x 4.4 inches.
Model | PCI-CAN/LS2 |
---|---|
Manufacturer | National Instruments |
Part Number | 778007-02 |
Type | CAN Interface Device |
Microprocessor | Intel 80386EX |
Ports | 2 |
Transceiver | TJA1054A |
Interface Type | ISO 11898 |
Maximum Baud Rate | 125 Kb/sec |
Minimum Baud Rate | 5 Kbps |
I/O Connector | 9-pin male D-SUB |
CAN_H, CAN_L Bus Lines | –27 to +40 VDC |
Isolation | Optical Isolation up to 500 V |
Power Requirements | + 5 VDC -- 900 mA |
Dimensions | 8.150 in. by 6.9 in. |
Software Driver | NI-CAN |
Warranty | 2-3 Year Warranty |
PCI-CAN/LS2 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PCI-CAN/LS2 Frequently Asked Questions
Question: Why can’t I find the PCI-CAN/LS2 anymore?
Answer: National Instruments has renamed the PCI-CAN/LS2. It is now the PCI-CAN.
Question: Can the NI PCI-CAN/LS2 communicate with a High-Speed device?
Answer: The NI PCI-CAN/LS2 cannot communicate with a high-speed device. The LS2 CAN card is a low-speed device that only communicates with other low-speed devices.
Question: What software does the PCI-CAN/LS2 come with?
Answer: The PCI-CAN/LS2 comes with NI-CAN driver software, a frame-based API.
PCI-CAN-LS2 PDF Manuals & Diagrams
PCI-CAN-LS2 PDF Manuals
ARCHIVED GETTING STARTED WITH YOUR CAN HARDWARE AND THE NI CAN SOFTWARE FOR WINDOWS 98 95.PDF
ARCHIVED GETTING STARTED WITH YOUR CAN HARDWARE AND THE NI CAN SOFTWARE FOR WINDOWS NT.PDF
ARCHIVED NI CAN USER MANUAL.PDF
NI CAN HARDWARE AND SOFTWARE MANUAL.PDF
NI DNET USER MANUAL AND SPECIFICATIONS.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."