Modular Systems > National Instruments > PXI Analyzers




Or speak to a sales representative for additional information:
PXI-1470 Request for Availablility
PXI-1470, 50 MHz to 26.5 GHz, PXI Vector Signal Analyzer
Need an Official Quote?
National Instruments PXI-1470 PXI Vector Signal Analyzer
The PXI-1470 is a PXI Vector Signal Analyzer. The NI PXI-1470 analyzer is designed and launched by National Instruments. The PXI-1470 is not a stand-alone module. The NI PXI-1470 is a complete modular kit that contains different components and modules. The main modules that come with the PXI-1470 kit are the PXIe-5622 IF Digitizer Module, the PXI-1430C RF Downconverter Module, the PXI-1450B Oscillator Source Module, the PXI-1420 MW Downconverter Module, and the PXI-1410 Pre-selector Module.
The PXI-1470 PXI Vector Signal Analyzer incorporates a 26.5 GHz processor. The internal storage of the NI PXI-1470 Analyzer is 256 MB. To achieve the best performance from the PXI-1470, it should be calibrated at regular intervals. The calibration interval recommended by the manufacturer is 1 year. Another precaution for using the NI PXI-1470 is that it should be warmed up for 20 minutes. The maximum power required by different modules in the PXI-1470 analyzer kit is different for each module. The minimum power consumed by the PXI-1420 module that is 11 W. However, the PXIe-5622 requires the maximum power up to 33 W. The resolution bandwidth of the PXI-1470 Signal Analyzer is in the range of 100 Hz – 50 MHz. The PXI-1470 VSA supports different triggering modes, including software edge, I/Q power edge, digital, and disable edge.
The PXI-1470 Vector Signal Analyzer supports Windows Vista/7/8/8.1. The installed operating system must include all important updates and service packs. The instrument driver required for the NI PXI-1470 Analyzer is NI-RFSA 2.9. The other required software is PXI-1470 Support.
PXI-1470 Obsolete Status has been announced by National Instruments, but the PXI Vector Signal Analyzer will still be available for purchase and repairs by Apex Waves.
Model | PXI-1470 |
---|---|
Manufacturer | National Instruments |
Type | PXI Vector Signal Analyzer |
Frequency Range | 50 MHz to 26.5 GHz |
Minimum Resolution Bandwidth | 100 Hz |
Maximum Resolution Bandwidth | 50 MHz |
Calibration Interval | 1 year |
Dimensions | 8.5 × 6.4 × 5.1 in. |
Weight | 8.6 lb. |
Warranty | 2-3 Year Warranty |
PXI-1470 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the PXI-1470:
159606A-01, 782620-01, 783471-01
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXI-1470
Modular Systems > National Instruments > PXI Analyzers
PXI-1470, 50 MHz to 26.5 GHz, PXI Vector Signal Analyzer
1-800-915-6216
- Description
- Technical Specifications
National Instruments PXI-1470 PXI Vector Signal Analyzer
The PXI-1470 is a PXI Vector Signal Analyzer. The NI PXI-1470 analyzer is designed and launched by National Instruments. The PXI-1470 is not a stand-alone module. The NI PXI-1470 is a complete modular kit that contains different components and modules. The main modules that come with the PXI-1470 kit are the PXIe-5622 IF Digitizer Module, the PXI-1430C RF Downconverter Module, the PXI-1450B Oscillator Source Module, the PXI-1420 MW Downconverter Module, and the PXI-1410 Pre-selector Module.
The PXI-1470 PXI Vector Signal Analyzer incorporates a 26.5 GHz processor. The internal storage of the NI PXI-1470 Analyzer is 256 MB. To achieve the best performance from the PXI-1470, it should be calibrated at regular intervals. The calibration interval recommended by the manufacturer is 1 year. Another precaution for using the NI PXI-1470 is that it should be warmed up for 20 minutes. The maximum power required by different modules in the PXI-1470 analyzer kit is different for each module. The minimum power consumed by the PXI-1420 module that is 11 W. However, the PXIe-5622 requires the maximum power up to 33 W. The resolution bandwidth of the PXI-1470 Signal Analyzer is in the range of 100 Hz – 50 MHz. The PXI-1470 VSA supports different triggering modes, including software edge, I/Q power edge, digital, and disable edge.
The PXI-1470 Vector Signal Analyzer supports Windows Vista/7/8/8.1. The installed operating system must include all important updates and service packs. The instrument driver required for the NI PXI-1470 Analyzer is NI-RFSA 2.9. The other required software is PXI-1470 Support.
PXI-1470 Obsolete Status has been announced by National Instruments, but the PXI Vector Signal Analyzer will still be available for purchase and repairs by Apex Waves.
Model | PXI-1470 |
---|---|
Manufacturer | National Instruments |
Type | PXI Vector Signal Analyzer |
Frequency Range | 50 MHz to 26.5 GHz |
Minimum Resolution Bandwidth | 100 Hz |
Maximum Resolution Bandwidth | 50 MHz |
Calibration Interval | 1 year |
Dimensions | 8.5 × 6.4 × 5.1 in. |
Weight | 8.6 lb. |
Warranty | 2-3 Year Warranty |
PXI-1470 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."