PXI-8196, 2.0 GHz Pentium M 760 Processor, PXI Controller
4.9/5 | 9 ratings
Fast Quote
Quoted Price

Need an Official Quote?

 

National Instruments PXI-8196 Embedded Controller

The National Instruments PXI-8196 is a high-performance, microprocessor-based Embedded Controller designed for use in PXI systems. This controller (Part Numbers: 779911-00, 779911-01, 779912-00, 779912-01) is powered by a 2.0 GHz Intel Pentium M 760 processor and includes 512 MB of DDR2 SDRAM, expandable to 1 GB or 2 GB using two DDR2 SO-DIMM modules. It also features a 30 GB or larger internal hard drive with a Fast Ultra ATA100 interface, making it well-suited for data-intensive applications.

The PXI-8196 includes an integrated Intel Graphics Media Accelerator 900 and provides an external SMB connector that can function as either a trigger input/output or watchdog timer. This SMB connector allows users to pass timing and trigger signals to and from the PXI trigger bus within a PXI system. Additionally, the PXI-8196 is equipped with a PCI-based GPIB controller and an ExpressCard/34 slot for system expansion.

This Embedded Controller is offered in two environmental configurations. The standard version operates within a temperature range of 5 to 50 °C, while the extended-temperature version supports an operating range from 0 to 55 °C. Both models are reliable solutions for a range of demanding industrial and laboratory settings.

The PXI-8196 supports a variety of National Instruments software platforms, including LabVIEW, Measurement Studio, and LabWindows/CVI. It is also compatible with NI-VISA, a uniform API used to communicate with and control a wide range of instruments across serial, GPIB, VXI, and PXI interfaces.

In terms of connectivity, the PXI-8196 provides a broad set of standard and extended I/O options. These include a VGA port (15-pin DSUB) for video output, a COM1 serial port (9-pin DSUB), an Ethernet port (RJ45), a parallel port (36-pin champ), and a USB interface consisting of four stacked 4-pin Series A ports. It also includes a GPIB interface (25-pin Micro D), a trigger input/output port (SMB), and an ExpressCard/34 slot. While the PXI-8196 does not have a native PS/2 connector, a PS/2 keyboard and mouse can still be used with the help of a USB Y-splitter cable.

The controller typically ships with Microsoft Windows XP pre-installed. Although National Instruments has announced the PXI-8196 as obsolete, it remains available for purchase and repair through Apex Waves. Apex Waves continues to support this controller with factory calibration, fast delivery, and optional software integration assistance.

ModelPXI-8196
Part Numbers779911-00, 779911-01, 779912-00, 779912-01
ManufacturerNational Instruments
HTS Code8471500150
TypePXI Controller
Slot Requirements1 system slot and 3 controller expansion slots
CPU2.0 GHz Pentium M 760
Standard RAM512 MB DDR2 SDRAM
Maximum RAM Capacity2 GB (2 x 1 GB DDR2 SO-DIMMs)
Hard Drive InterfaceUltra ATA100 (30 GB or larger)
Operating TemperatureStandard: 5 to 50 °C, Extended: 0 to 55 °C
Dimensions3.2 x 5.1 x 8.5 in.
Weight1.7 lb.
WarrantyThree Year Warranty
PXI-8196 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

Associated part numbers for the PXI-8196:

1.91435E-07, 1.91435E-17, 191134C-01, 191134D-01, 191244B-01, 191244C-01, 191244D-01, 191435-722, 191435A-012, 191435A-022, 191435A-712, 191435A-722, 191435B-012, 191435B-022, 191435B-712, 191435B-722, 191435C-022, 191435C-712, 191435C-722, 191435D-722, 191435E-712, 191435E-722, 779911-00, 779911-01, 779911-11, 779911-33, 779912-00, 779912-01, 779912-33


Associated NSNs for the PXI-8196:

5998-01-549-8927 (5998015498927), 5998-01-567-2161 (5998015672161), 7025-01-596-6834 (7025015966834), 5998016416375, 5998-01-641-6375 (5998016416375)

National Instruments PXI-8196 Frequently Asked Questions

Question: Why are there multiple part numbers for the PXI 8196 Controller?

Answer: The PXI 8196 Controller has several operating systems available, as well as a bade model and an extended temperature model. Part number 779911-01 is the base model with Windows XP (English) installed and part number 779912-01 is the extended temperature model with Windows XP (English) installed. Part number 779911-00 is the base model with Localized OS, while part number 779912-00 is the extended temperature model with Localized OS.

 

Question: What is the Dual-Channel DDR2 RAM maximum on the NI PXI-8196 Embedded Controller? 

Answer: On the NI PXI-8196 Embedded Controller, the Dual-Channel DDR2 RAM maximum is 2 GB.

 

Question: Does the PXI-8196 have a GPIB (IEEE 488.2) Interface?

Answer: Yes, the PXI-8196 has a GPIB (IEEE 488.2) Interface.

 

Question: What is the typical current for the NI PXI-8196 at +5 V voltage?

Answer: The typical current for the NI PXI-8196 at +5 V is 5.0 A, and the maximum current is 7.0 A

  PXI-8196 PDF Manuals

  PXI-8196 Diagrams


Why Buy From Apex Waves:

Apex Waves Youtube Video

"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: PAI-8196, PXJ-8196, PXI-I196, PXI-8W96, PXI-81I6

PXI-8196



Modular Systems > National Instruments > PXI Controllers

PXI-8196, 2.0 GHz Pentium M 760 Processor, PXI Controller
4.9/5 | 9 ratings

Call now for best pricing
1-800-915-6216

National Instruments PXI-8196 Embedded Controller

The National Instruments PXI-8196 is a high-performance, microprocessor-based Embedded Controller designed for use in PXI systems. This controller (Part Numbers: 779911-00, 779911-01, 779912-00, 779912-01) is powered by a 2.0 GHz Intel Pentium M 760 processor and includes 512 MB of DDR2 SDRAM, expandable to 1 GB or 2 GB using two DDR2 SO-DIMM modules. It also features a 30 GB or larger internal hard drive with a Fast Ultra ATA100 interface, making it well-suited for data-intensive applications.

The PXI-8196 includes an integrated Intel Graphics Media Accelerator 900 and provides an external SMB connector that can function as either a trigger input/output or watchdog timer. This SMB connector allows users to pass timing and trigger signals to and from the PXI trigger bus within a PXI system. Additionally, the PXI-8196 is equipped with a PCI-based GPIB controller and an ExpressCard/34 slot for system expansion.

This Embedded Controller is offered in two environmental configurations. The standard version operates within a temperature range of 5 to 50 °C, while the extended-temperature version supports an operating range from 0 to 55 °C. Both models are reliable solutions for a range of demanding industrial and laboratory settings.

The PXI-8196 supports a variety of National Instruments software platforms, including LabVIEW, Measurement Studio, and LabWindows/CVI. It is also compatible with NI-VISA, a uniform API used to communicate with and control a wide range of instruments across serial, GPIB, VXI, and PXI interfaces.

In terms of connectivity, the PXI-8196 provides a broad set of standard and extended I/O options. These include a VGA port (15-pin DSUB) for video output, a COM1 serial port (9-pin DSUB), an Ethernet port (RJ45), a parallel port (36-pin champ), and a USB interface consisting of four stacked 4-pin Series A ports. It also includes a GPIB interface (25-pin Micro D), a trigger input/output port (SMB), and an ExpressCard/34 slot. While the PXI-8196 does not have a native PS/2 connector, a PS/2 keyboard and mouse can still be used with the help of a USB Y-splitter cable.

The controller typically ships with Microsoft Windows XP pre-installed. Although National Instruments has announced the PXI-8196 as obsolete, it remains available for purchase and repair through Apex Waves. Apex Waves continues to support this controller with factory calibration, fast delivery, and optional software integration assistance.

ModelPXI-8196
Part Numbers779911-00, 779911-01, 779912-00, 779912-01
ManufacturerNational Instruments
HTS Code8471500150
TypePXI Controller
Slot Requirements1 system slot and 3 controller expansion slots
CPU2.0 GHz Pentium M 760
Standard RAM512 MB DDR2 SDRAM
Maximum RAM Capacity2 GB (2 x 1 GB DDR2 SO-DIMMs)
Hard Drive InterfaceUltra ATA100 (30 GB or larger)
Operating TemperatureStandard: 5 to 50 °C, Extended: 0 to 55 °C
Dimensions3.2 x 5.1 x 8.5 in.
Weight1.7 lb.
WarrantyThree Year Warranty
PXI-8196 ManualUser Manual and Maintenance Manual Available for Download
PriceContact a sales representative for a quote.

National Instruments PXI-8196 Frequently Asked Questions

Question: Why are there multiple part numbers for the PXI 8196 Controller?

Answer: The PXI 8196 Controller has several operating systems available, as well as a bade model and an extended temperature model. Part number 779911-01 is the base model with Windows XP (English) installed and part number 779912-01 is the extended temperature model with Windows XP (English) installed. Part number 779911-00 is the base model with Localized OS, while part number 779912-00 is the extended temperature model with Localized OS.

 

Question: What is the Dual-Channel DDR2 RAM maximum on the NI PXI-8196 Embedded Controller? 

Answer: On the NI PXI-8196 Embedded Controller, the Dual-Channel DDR2 RAM maximum is 2 GB.

 

Question: Does the PXI-8196 have a GPIB (IEEE 488.2) Interface?

Answer: Yes, the PXI-8196 has a GPIB (IEEE 488.2) Interface.

 

Question: What is the typical current for the NI PXI-8196 at +5 V voltage?

Answer: The typical current for the NI PXI-8196 at +5 V is 5.0 A, and the maximum current is 7.0 A

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150