Modular Systems > National Instruments > PXI Relay Modules




Or speak to a sales representative for additional information:
PXI-2542 Request for Availablility
PXI-2542, 6.6 GHz, PXI RF Relay Module
Need an Official Quote?
National Instruments PXI-2542 Switching Module
The National Instruments PXI-2542 (Part Number: 778572-42) is a terminated switching module that serves to route RF signals for creation test applications. It has superior solid-state relays that offer remarkable advantages, such as a boundless mechanical life and quick switching time. Front-mount SMA connectors offer simple association with the user’s RF gadgets and the module has termination on each channel and COM line. The termination of the channel and the COM lines help lessen reflections of the RF signal and ensure the user’s instruments.
This model includes an input trigger that is sourced by another instrument or by programming and causes the NI PXI-2542 to advance to the following section in the scan list. The triggers can be routed to any of the PXI TTL triggers or to the PXI star trigger. If no outside trigger input is accessible, the user can have the software trigger to the NI PXI-2542 advance to the following entry in the scan list.
LabVIEW and LabWindows/CVI are innovative program improvement software packages for data acquisition and control applications incorporated in this model. LabVIEW utilizes graphical programming, while LabWindows/CVI upgrades traditional programming languages. The two packages incorporate broad libraries for data acquisition, instrument control, data analysis, and graphical data presentation. Utilizing LabVIEW or LabWindows/CVI can fundamentally diminish the development time for the user’s data acquisition and control application.
If you are interested in this model and you want to learn more about its options, special features, and specifications, you can read its manual, which is available on the ApexWaves.com website.
Model | PXI-2542 (778572-42) |
---|---|
Manufacturer | National Instruments |
Type | PXI RF Relay Module |
Banks | 4 |
Switch Bandwidth | 6.6 GHz |
Characteristic Impedance | 50 Ohms |
Dimensions | 8.5 x 0.8 x 5.1 in. |
Weight | 19.5 oz. |
Warranty | 2-3 Year Warranty |
PXI-2542 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the PXI-2542:
153939A-01L, 153939B-01L, 153939C-01L, 153939D-01L, 778572-42
National Instruments PXI-2542 Frequently Asked Questions
Question: What switch type does the PXI-2542 have?
Answer: The PXI-2542 has FET switches.
Question: What is the minimum input frequency for the NI PXI-2542?
Answer: The minimum input frequency for the NI PXI-2542 is 10 MHz.
Question: What type of I/O connectors does the PXI-2542 have on the front panel?
Answer: The PXI-2542 has 12 SMA jacks, female on the front panel.
Question: What is the scan rate of the PXI-2542 RF Relay Module?
Answer: The PXI-2542 RF Relay Module has a scan rate of 8,000 cycles/s.
PXI-2542 PDF Manuals
NI PXI PXIE 2542 SPECIFICATIONS.PDF
PXI PXIE 2542 2543 2544 LETTER OF VOLATILITY.PDF
PXI-2542 Diagrams
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXI-2542
Modular Systems > National Instruments > PXI Relay Modules
PXI-2542, 6.6 GHz, PXI RF Relay Module
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments PXI-2542 Switching Module
The National Instruments PXI-2542 (Part Number: 778572-42) is a terminated switching module that serves to route RF signals for creation test applications. It has superior solid-state relays that offer remarkable advantages, such as a boundless mechanical life and quick switching time. Front-mount SMA connectors offer simple association with the user’s RF gadgets and the module has termination on each channel and COM line. The termination of the channel and the COM lines help lessen reflections of the RF signal and ensure the user’s instruments.
This model includes an input trigger that is sourced by another instrument or by programming and causes the NI PXI-2542 to advance to the following section in the scan list. The triggers can be routed to any of the PXI TTL triggers or to the PXI star trigger. If no outside trigger input is accessible, the user can have the software trigger to the NI PXI-2542 advance to the following entry in the scan list.
LabVIEW and LabWindows/CVI are innovative program improvement software packages for data acquisition and control applications incorporated in this model. LabVIEW utilizes graphical programming, while LabWindows/CVI upgrades traditional programming languages. The two packages incorporate broad libraries for data acquisition, instrument control, data analysis, and graphical data presentation. Utilizing LabVIEW or LabWindows/CVI can fundamentally diminish the development time for the user’s data acquisition and control application.
If you are interested in this model and you want to learn more about its options, special features, and specifications, you can read its manual, which is available on the ApexWaves.com website.
Model | PXI-2542 (778572-42) |
---|---|
Manufacturer | National Instruments |
Type | PXI RF Relay Module |
Banks | 4 |
Switch Bandwidth | 6.6 GHz |
Characteristic Impedance | 50 Ohms |
Dimensions | 8.5 x 0.8 x 5.1 in. |
Weight | 19.5 oz. |
Warranty | 2-3 Year Warranty |
PXI-2542 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXI-2542 Frequently Asked Questions
Question: What switch type does the PXI-2542 have?
Answer: The PXI-2542 has FET switches.
Question: What is the minimum input frequency for the NI PXI-2542?
Answer: The minimum input frequency for the NI PXI-2542 is 10 MHz.
Question: What type of I/O connectors does the PXI-2542 have on the front panel?
Answer: The PXI-2542 has 12 SMA jacks, female on the front panel.
Question: What is the scan rate of the PXI-2542 RF Relay Module?
Answer: The PXI-2542 RF Relay Module has a scan rate of 8,000 cycles/s.
PXI-2542 PDF Manuals & Diagrams
PXI-2542 PDF Manuals
NI PXI PXIE 2542 SPECIFICATIONS.PDF
PXI PXIE 2542 2543 2544 LETTER OF VOLATILITY.PDF
PXI-2542 Diagrams
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."