National Instruments - PXI Signal Generator Modules - PXIe-5696National Instruments - PXI Signal Generator Modules - PXIe-5696 - WiringPXIe-5696 NewPXIe-5696 | Legacy, Refurbished and New Surplus
National Instruments - PXI Signal Generator Modules - PXIe-5696
National Instruments - PXI Signal Generator Modules - PXIe-5696 - Wiring
PXIe-5696 New
PXIe-5696 | Legacy, Refurbished and New Surplus

PXIe-5696

4.48/5 | 12 ratings

Modular Systems > National Instruments > PXI Signal Generator Modules

Part Number PXIe-5696
Manufacturer/Brand National Instruments
Description: PXIe-5696, 2 Slot, Amplitude Extender for use with the NI PXIe-5654
Request for Availablility
Fast Quote
Quoted Price
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Need an Official Quote?

 

Or speak to a sales representative for additional information:


National Instruments PXIe-5696 Amplitude Extender

The National Instruments PXIe-5696 (part number: 783128-01) is an Amplitude Extender designed for use with the PXIe-5654 RF Analog Signal Generator. When used together, the PXIe-5696 raises the amplitude range up to 27 dBm. Equipped with 2 slots, this amplitude extender is an invaluable tool for all manner of applications that use the PXIe-5654.

To achieve optimal functionality between the PXIe-5696 and the PXIe-5654, cabling should be kept as short as possible to avoid picking up excess noise. A 30 minute warmup time before use helps ensure that both devices are at a stable operating temperature.

The DC power requirements of the PXIe-5696 differs depending on the power rail that is used. The maximum current drawn by a power rail of +3.3 V is 3 A, while the typical draw is 2.2 A. A power rail of +12 V has a maximum current draw of 2.8 A and a typical draw of 1.6 A.

Designed to withstand a wide range of indoor environmental conditions, the PXIe-5696 functions well in altitudes up to 2,000 m. The device should only be operated in locations where the temperatures are kept within a range of 0 °C to 55 °C. In addition, the relative humidity of the operating environment should be noncondensing and kept within a range of 10% to 90%.

The 3U PXI Express Module size of the PXIe-5696 measures 4.1 cm x 13.0 cm x 21.4 cm (1.6 in. x 5.1 in. x 8.4 in.) in dimensions, and it weighs an easily portable 894 g (31.5 oz).

Model NamePXIe-5696
Part Number783128-01
Part TypeAmplitude Extender
For Use WithNI PXIe-5654
Maximum DC Power Requirement3 A (+3.3 V), 2.8 A (+12 V)
Typical DC Power Requirement2.2 A (+3.3 V), 1.6 A (+12 V)
Slots2
Dimensions4.1 cm x 13.0 cm x 21.4 cm (1.6 in. x 5.1 in. x 8.4 in.)
Weight894 g (31.5 oz)
WarrantyThree Year Warranty
ManufacturerNational Instruments

National Instruments PXIe-5696 Frequently Asked Questions

What is the role of the PXIe-5696 with the PXIe-5654?

You can use the PXIe-5696 AE to extend the amplitude range and enhance the amplitude accuracy of the PXIe-5654 from -110 dBm to +30 dBm, according to frequency.

Is the PXIe-5696 compatible with other PXIe analog signal generators?

No, the PXIe-5696 amplitude extender is built specifically for the PXIe-5654 analog signal generator.

How do I connect the PXIe-5654 to the PXIe-5696?

You can conect the PXIe-5654 and PXIe-5696 hardware modules using high quality SMA-to-SMA and SMB-to-SMB coaxial cables.​​​​​​​

  PXIe-5696 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: OXIE-5696, LXIE-5696, PXIF-5696, PXIE-5T96, PXIE-56I6

PXIe-5696



Modular Systems > National Instruments > PXI Signal Generator Modules

PXIe-5696
4.48/5 | 12 ratings

PXIe-5696, 2 Slot, Amplitude Extender for use with the NI PXIe-5654

Request for Availablility
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping
  Get Pricing

Call now for best pricing
1-800-915-6216

National Instruments PXIe-5696 Amplitude Extender

The National Instruments PXIe-5696 (part number: 783128-01) is an Amplitude Extender designed for use with the PXIe-5654 RF Analog Signal Generator. When used together, the PXIe-5696 raises the amplitude range up to 27 dBm. Equipped with 2 slots, this amplitude extender is an invaluable tool for all manner of applications that use the PXIe-5654.

To achieve optimal functionality between the PXIe-5696 and the PXIe-5654, cabling should be kept as short as possible to avoid picking up excess noise. A 30 minute warmup time before use helps ensure that both devices are at a stable operating temperature.

The DC power requirements of the PXIe-5696 differs depending on the power rail that is used. The maximum current drawn by a power rail of +3.3 V is 3 A, while the typical draw is 2.2 A. A power rail of +12 V has a maximum current draw of 2.8 A and a typical draw of 1.6 A.

Designed to withstand a wide range of indoor environmental conditions, the PXIe-5696 functions well in altitudes up to 2,000 m. The device should only be operated in locations where the temperatures are kept within a range of 0 °C to 55 °C. In addition, the relative humidity of the operating environment should be noncondensing and kept within a range of 10% to 90%.

The 3U PXI Express Module size of the PXIe-5696 measures 4.1 cm x 13.0 cm x 21.4 cm (1.6 in. x 5.1 in. x 8.4 in.) in dimensions, and it weighs an easily portable 894 g (31.5 oz).

Model NamePXIe-5696
Part Number783128-01
Part TypeAmplitude Extender
For Use WithNI PXIe-5654
Maximum DC Power Requirement3 A (+3.3 V), 2.8 A (+12 V)
Typical DC Power Requirement2.2 A (+3.3 V), 1.6 A (+12 V)
Slots2
Dimensions4.1 cm x 13.0 cm x 21.4 cm (1.6 in. x 5.1 in. x 8.4 in.)
Weight894 g (31.5 oz)
WarrantyThree Year Warranty
ManufacturerNational Instruments

National Instruments PXIe-5696 Frequently Asked Questions

What is the role of the PXIe-5696 with the PXIe-5654?

You can use the PXIe-5696 AE to extend the amplitude range and enhance the amplitude accuracy of the PXIe-5654 from -110 dBm to +30 dBm, according to frequency.

Is the PXIe-5696 compatible with other PXIe analog signal generators?

No, the PXIe-5696 amplitude extender is built specifically for the PXIe-5654 analog signal generator.

How do I connect the PXIe-5654 to the PXIe-5696?

You can conect the PXIe-5654 and PXIe-5696 hardware modules using high quality SMA-to-SMA and SMB-to-SMB coaxial cables.​​​​​​​

Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn