PXIe-2512, 7-Channel, PXI Signal Insertion Switch Module
Need an Official Quote?
National Instruments PXIe-2512 PXI Signal Insertion Switch Module
The PXIe-2512 (Part Number: 780587-12) is a Switch Module for Signal Insertion from National Instruments. The instrument comes with built-in FET relays. The NI PXIe-2512 Signal Insertion Switch Module offers seven different channels for testing. The high-performance special design enables users to implement the module for various testing applications. The built-in fault insertion unit (FIU) enables users to conduct electronic reliability tests and helps fulfill testing needs for applications involving hardware-in-the-loop (HIL). It also offers the capability to simulate open or interrupted connection. It enables users to meet various testing criteria. The user can also short connections between pins, short to battery voltages, or to ground. This can be accomplished separately for each channel.
The NI PXIe-2512 Signal Insertion Switch Module can offer continuous or pulsed current. The maximum value of continuous current is 10 amperes, which can be provided in the per channel or common mode of operation. The maximum value for pulsed current is 50 amperes for a maximum interval of 600 microseconds. The typical value of DC path resistance is 16 milliohms. The NI PXIe-2512 module also incorporates overcurrent and over temperature detection capabilities.
The NI PXIe 2512 depicts extraordinary dynamic characteristics. The typical time for relay operation is eight microseconds. The maximum value of time for relay operation is 35 microseconds. The input trigger of the device has a minimum pulse width of 150 nanoseconds. There is also a programmable output trigger. The pulse width for the output trigger ranges from 1 to 62 microseconds. The NI PXIe-2512 is suitable for testing control systems and engine control units. This module can be operated with the LabVIEW Real-Time Module for such testing requirements.
Model | PXIe-2512 |
---|---|
Part Number | 780587-12 |
Manufacturer | National Instruments |
Type | PXI Signal Insertion Switch Module |
Channels | 7 |
Relay Type | FET |
Switch Bandwidth | 800 kHz |
Dimensions | 8.5 x 1.6 x 5.1 in. |
Weight | 14.2 oz. |
Warranty | 2-3 Year Warranty |
PXIe-2512 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the PXIe-2512:
196431A-01L, 196431B-01L, 196431C-01L, 780587-12
National Instruments PXIe-2512 Frequently Asked Questions
Question: What is the maximum switching voltage DC for the PXIe-2512?
Answer: The maximum switching voltage DC for the PXIe-2512 is 50 V.
Question: What type of front panel connectors are on the NI PXIe-2512?
Answer: The NI PXIe-2512 has two DSUB, 8 positions, male front panel connectors.
Question: What is the output trigger pulse width on the PXIe-2512?
Answer: On the PXIe-2512, the output trigger pulse width is programmable from 1 µs to 62 µs.
Question: What are the power requirements for the NI PXIe-2512?
Answer: The NI PXIe-2512 has a power requirement of 14.7 W at +12 V and 1.4 W at 3.3 V.
PXIe-2512 PDF Manuals
NI PXI PXIE 2512 SPECIFICATIONS.PDF
PXI PXIE 2512 2514 LETTER OF VOLATILITY.PDF
Driver Downloads for PXIe-2512
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-2512
Modular Systems > National Instruments > PXI Signal Insertion Modules
PXIe-2512, 7-Channel, PXI Signal Insertion Switch Module
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments PXIe-2512 PXI Signal Insertion Switch Module
The PXIe-2512 (Part Number: 780587-12) is a Switch Module for Signal Insertion from National Instruments. The instrument comes with built-in FET relays. The NI PXIe-2512 Signal Insertion Switch Module offers seven different channels for testing. The high-performance special design enables users to implement the module for various testing applications. The built-in fault insertion unit (FIU) enables users to conduct electronic reliability tests and helps fulfill testing needs for applications involving hardware-in-the-loop (HIL). It also offers the capability to simulate open or interrupted connection. It enables users to meet various testing criteria. The user can also short connections between pins, short to battery voltages, or to ground. This can be accomplished separately for each channel.
The NI PXIe-2512 Signal Insertion Switch Module can offer continuous or pulsed current. The maximum value of continuous current is 10 amperes, which can be provided in the per channel or common mode of operation. The maximum value for pulsed current is 50 amperes for a maximum interval of 600 microseconds. The typical value of DC path resistance is 16 milliohms. The NI PXIe-2512 module also incorporates overcurrent and over temperature detection capabilities.
The NI PXIe 2512 depicts extraordinary dynamic characteristics. The typical time for relay operation is eight microseconds. The maximum value of time for relay operation is 35 microseconds. The input trigger of the device has a minimum pulse width of 150 nanoseconds. There is also a programmable output trigger. The pulse width for the output trigger ranges from 1 to 62 microseconds. The NI PXIe-2512 is suitable for testing control systems and engine control units. This module can be operated with the LabVIEW Real-Time Module for such testing requirements.
Model | PXIe-2512 |
---|---|
Part Number | 780587-12 |
Manufacturer | National Instruments |
Type | PXI Signal Insertion Switch Module |
Channels | 7 |
Relay Type | FET |
Switch Bandwidth | 800 kHz |
Dimensions | 8.5 x 1.6 x 5.1 in. |
Weight | 14.2 oz. |
Warranty | 2-3 Year Warranty |
PXIe-2512 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXIe-2512 Frequently Asked Questions
Question: What is the maximum switching voltage DC for the PXIe-2512?
Answer: The maximum switching voltage DC for the PXIe-2512 is 50 V.
Question: What type of front panel connectors are on the NI PXIe-2512?
Answer: The NI PXIe-2512 has two DSUB, 8 positions, male front panel connectors.
Question: What is the output trigger pulse width on the PXIe-2512?
Answer: On the PXIe-2512, the output trigger pulse width is programmable from 1 µs to 62 µs.
Question: What are the power requirements for the NI PXIe-2512?
Answer: The NI PXIe-2512 has a power requirement of 14.7 W at +12 V and 1.4 W at 3.3 V.
PXIe-2512 PDF Manuals & Diagrams
PXIe-2512 PDF Manuals
NI PXI PXIE 2512 SPECIFICATIONS.PDF
PXI PXIE 2512 2514 LETTER OF VOLATILITY.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."