Modular Systems > National Instruments > SC Series




Or speak to a sales representative for additional information:
SC-2062 In Stock | Ships Today
SC-2062, 8-Channel, Electromechanical Relay Digital Output Board
Need an Official Quote?
National Instruments SC-2062 Electromechanical Relay Digital Output Board
The SC-2062 is an Electromechanical Relay Board with multiple different part numbers: 776336-02 with a 0.2 m NB7 SC-205X Cable and 776336-12 with a 0.4 m NB7 SC-205x Cable. It can also be found with part number 180937C-01. This Relay Board can be mounted to sit on a workbench or in a rack-mount chassis with a flat plastic cover or metal wraparound cover. Like the other models in the SC-206x Series, the NI SC-2062 can be linked to any 8-bit digital port of many NI DAQ instruments. The user simply has to utilize the SC-205x Series cable adapters. Several of the DAQ devices which can be linked to the SC-2062 include: the E Series/60xxE, 6503 (DIO-24), 6533 (DIO-32HS), as well as 6508 (DIO-96). The NI SC-2062 does not require any software other than what is required for the Data Acquisition Board used with it.
The SC-2062 enables the user to effortlessly control various field digital signals with a computer that has a National Instruments data acquisition board. When the SC-2062 is used with a model from the SC-205x Series, the SC-2062 can deliver relay output for the NI data acquisition boards for the following computers: PC/XT/AT, Macintosh II, and IBM PS/2 Micro Channel computers.
There are three links for each channel on the NI SC-2062: NO, NC, and COM. There is a tiny opening between the screw terminal blocks of nearby channels. A note of caution is that while connecting or disconnecting signal lines to the screw terminals, it is necessary to turn the power off the lines. Variations between the lines and the SC-2062 ground generate a shock risk while joining the lines. Additionally, power signals to ground should not surpass the maximum input or output signal ratings on the SC-2062 Relay to prevent the board from being damaged. The NI device is equipped with one 26-pin male ribbon-cable connector and 26 screw terminals.
The NI device measures 5.2 x 4.9 x 1.8 in. in physical dimensions. It has a recommended operating temperature range of 0° to 70° C, a storage temperature range of -55° to 125° C, noncondensing operating and storage humidity ranges of 5% to 90%.
Model | SC-2062 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 776336-02, 776336-12, 180937C-01 |
Series | SC Series |
Type | Electromechanical Relay |
Channels | 8 |
Relay Type | SPDT (1 Form C) |
Dimensions | 5.2 by 4.9 by 1.8 in. |
I/O Connectors | One 26-pin male ribbon-cable connector and 26 screw terminals |
Warranty | Three Year Warranty |
SC-2062 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the SC-2062:
180935-01, 180935-01B, 180935C-01, 180937C-01, 776336-02, 776336-12
Associated NSNs for the SC-2062:
5998-01-645-9500 (5998016459500)
National Instruments SC-2062 Frequently Asked Questions
Question: What devices are compatible with the NI SC-2062?
Answer: The devices that are compatible with the NI SC-2062 include: 60xxE (E Series), 6503 (DIO-24), 6533 (DIO-32HS), and 6508 (DIO-96).
Question: What size rackmount does the SC-2062 fit in?
Answer: The SC-2062 fits in a 19 in. rackmount, which can also fit a device from the SC-205x Series at the same time.
Question: What type of relays does the SC-062 have?
Answer: The SC-2062 has SPDT (1 Form C) Relays.
Question: What type of I/O connectors does the NI SC-2062 Relay have?
Answer: The NI SC-2062 Relay has one 26-pin male ribbon-cable connector and 26 screw terminals.
Question: What is the working voltage of the SC-2062?
Answer: The working voltage of the SC-2062 is 250 Vrms contact-to-contact and 250 Vrms contact-to-ground.
SC-2062 PDF Manuals
ARCHIVED AT DIO 32F USER MANUAL.PDF
ARCHIVED AT MIO 16D USER MANUAL.PDF
ARCHIVED AT MIO 64F 5 USER MANUAL.PDF
ARCHIVED BNC 208X SERIES USER MANUAL.PDF
ARCHIVED CB 27T TBX 68T AND CB 68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE.PDF
ARCHIVED NB MIO 16X USER MANUAL.PDF
ARCHIVED NI 435X USER MANUAL.PDF
NOTE TO USERS SC 206X SERIES BOARDS REQUIRE UL RECOGNIZED COMPONENT STYLE NO. 1569 WIRING.PDF
SC 205X SERIES USER MANUAL.PDF
SC 206X SERIES USER MANUAL.PDF
SC 207X SERIES USER MANUAL.PDF
USING MODULES AND ACCESSORIES WITH THE SC 2056.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
SC-2062
Modular Systems > National Instruments > SC Series
SC-2062, 8-Channel, Electromechanical Relay Digital Output Board
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments SC-2062 Electromechanical Relay Digital Output Board
The SC-2062 is an Electromechanical Relay Board with multiple different part numbers: 776336-02 with a 0.2 m NB7 SC-205X Cable and 776336-12 with a 0.4 m NB7 SC-205x Cable. It can also be found with part number 180937C-01. This Relay Board can be mounted to sit on a workbench or in a rack-mount chassis with a flat plastic cover or metal wraparound cover. Like the other models in the SC-206x Series, the NI SC-2062 can be linked to any 8-bit digital port of many NI DAQ instruments. The user simply has to utilize the SC-205x Series cable adapters. Several of the DAQ devices which can be linked to the SC-2062 include: the E Series/60xxE, 6503 (DIO-24), 6533 (DIO-32HS), as well as 6508 (DIO-96). The NI SC-2062 does not require any software other than what is required for the Data Acquisition Board used with it.
The SC-2062 enables the user to effortlessly control various field digital signals with a computer that has a National Instruments data acquisition board. When the SC-2062 is used with a model from the SC-205x Series, the SC-2062 can deliver relay output for the NI data acquisition boards for the following computers: PC/XT/AT, Macintosh II, and IBM PS/2 Micro Channel computers.
There are three links for each channel on the NI SC-2062: NO, NC, and COM. There is a tiny opening between the screw terminal blocks of nearby channels. A note of caution is that while connecting or disconnecting signal lines to the screw terminals, it is necessary to turn the power off the lines. Variations between the lines and the SC-2062 ground generate a shock risk while joining the lines. Additionally, power signals to ground should not surpass the maximum input or output signal ratings on the SC-2062 Relay to prevent the board from being damaged. The NI device is equipped with one 26-pin male ribbon-cable connector and 26 screw terminals.
The NI device measures 5.2 x 4.9 x 1.8 in. in physical dimensions. It has a recommended operating temperature range of 0° to 70° C, a storage temperature range of -55° to 125° C, noncondensing operating and storage humidity ranges of 5% to 90%.
Model | SC-2062 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 776336-02, 776336-12, 180937C-01 |
Series | SC Series |
Type | Electromechanical Relay |
Channels | 8 |
Relay Type | SPDT (1 Form C) |
Dimensions | 5.2 by 4.9 by 1.8 in. |
I/O Connectors | One 26-pin male ribbon-cable connector and 26 screw terminals |
Warranty | Three Year Warranty |
SC-2062 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments SC-2062 Frequently Asked Questions
Question: What devices are compatible with the NI SC-2062?
Answer: The devices that are compatible with the NI SC-2062 include: 60xxE (E Series), 6503 (DIO-24), 6533 (DIO-32HS), and 6508 (DIO-96).
Question: What size rackmount does the SC-2062 fit in?
Answer: The SC-2062 fits in a 19 in. rackmount, which can also fit a device from the SC-205x Series at the same time.
Question: What type of relays does the SC-062 have?
Answer: The SC-2062 has SPDT (1 Form C) Relays.
Question: What type of I/O connectors does the NI SC-2062 Relay have?
Answer: The NI SC-2062 Relay has one 26-pin male ribbon-cable connector and 26 screw terminals.
Question: What is the working voltage of the SC-2062?
Answer: The working voltage of the SC-2062 is 250 Vrms contact-to-contact and 250 Vrms contact-to-ground.
SC-2062 PDF Manuals & Diagrams
SC-2062 PDF Manuals
ARCHIVED AT DIO 32F USER MANUAL.PDF
ARCHIVED AT MIO 16D USER MANUAL.PDF
ARCHIVED AT MIO 64F 5 USER MANUAL.PDF
ARCHIVED BNC 208X SERIES USER MANUAL.PDF
ARCHIVED CB 27T TBX 68T AND CB 68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE.PDF
ARCHIVED NB MIO 16X USER MANUAL.PDF
ARCHIVED NI 435X USER MANUAL.PDF
NOTE TO USERS SC 206X SERIES BOARDS REQUIRE UL RECOGNIZED COMPONENT STYLE NO. 1569 WIRING.PDF
SC 205X SERIES USER MANUAL.PDF
SC 206X SERIES USER MANUAL.PDF
SC 207X SERIES USER MANUAL.PDF
USING MODULES AND ACCESSORIES WITH THE SC 2056.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."