SCXI-1192, 8-Channel, SPDT Relay Module
Need an Official Quote?
National Instruments SCXI-1192 Relay Module
The SCXI-1192 general-purpose 18 GHz module can handle RF signals to a maximum of 18 GHz. This module has 8 SPDT relays with 2 channels per relay and is not supportive of routing signals to the high-voltage analog bus. The maximum rated voltage of the module is 30 V, whereas the maximum rated current is 2 A at 30 V. For the NI SCXI-1192 and other SCXI modules, the user has the option to auto-detect the modules or manually add them. The choice is based on the user’s application. When the user chooses auto-detect and the chassis is not an SCXI-2000 remote chassis, then the user must ensure the chassis has been connected to an NI instrument. It is imperative to remember to not take the SCXI 1192 Relay Module out of a chassis that is powered on. Doing so may result in harm to the module.
The NI SCXI-1192 has 24 screw-on SMA jacks for the I/O connectors. The relays on this module are latching electromechanical relays with a gold plate contact material. Since this Relay Module has latching relays, there is not a defined power-up state. Instead, the relays will maintain their state in case of power loss. The rest mode of the SCXI-1192 joins NC to COM for every relay. In addition, the NI SCXI-1192 can be utilized to route signals from two RF sources to a single RF measurement instrument. These measurement instruments include a Scope, a Spectrum Analyzer, or a Power Meter.
SCXI-1192 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves.
Model | SCXI-1192 |
---|---|
Manufacturer | National Instruments |
Type | Relay Module |
Configuration | 8-Channel SPDT |
Number of Channels per Relay | 2 |
I/O Connectors | 24 SMA jacks |
Dimensions | 1.2 in. × 6.7 in. × 7.6 in. |
Weight | 2 lb. 7 oz. |
Warranty | 2-3 Year Warranty |
SCXI-1192 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the SCXI-1192:
186676B-04, 186676C-04, 187436A-01, 187670A-01, 776572-92
National Instruments SCXI-1192 Frequently Asked Questions
Question: How do I test and configure the SCXI-1192?
Answer: To test and configure the SCXI-1192, run measurement and automation explorer (MAX).
Question: What should I do if I get stuck during the configuration or testing of the SCXI 1192?
Answer: If you need help during the configuration process of your SCXI 1192, open the Measurement & Automation Help file.
Question: What is the maximum rated voltage of the switch on the NI SCXI-1192?
Answer: For the NI SCXI-1192, the maximum rated voltage of the switch is 30 V and the maximum rated current is 2 A at 30 V.
SCXI-1192 PDF Manuals
ARCHIVED NI SCXI-1192 SPECIFICATIONS.PDF
ARCHIVED SCXI 1190 1191 1192 USER MANUAL.PDF
ARCHIVED SCXI 1362 ADAPTER KIT INSTALLATION GUIDE.PDF
ARCHIVED TRADITIONAL NI DAQ USER MANUAL.PDF
NI SWITCHES GETTING STARTED GUIDE FOR NI SCXI SWITCH MODULES.PDF
Driver Downloads for SCXI-1192
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
SCXI-1192
Modular Systems > National Instruments > SCXI
SCXI-1192, 8-Channel, SPDT Relay Module
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments SCXI-1192 Relay Module
The SCXI-1192 general-purpose 18 GHz module can handle RF signals to a maximum of 18 GHz. This module has 8 SPDT relays with 2 channels per relay and is not supportive of routing signals to the high-voltage analog bus. The maximum rated voltage of the module is 30 V, whereas the maximum rated current is 2 A at 30 V. For the NI SCXI-1192 and other SCXI modules, the user has the option to auto-detect the modules or manually add them. The choice is based on the user’s application. When the user chooses auto-detect and the chassis is not an SCXI-2000 remote chassis, then the user must ensure the chassis has been connected to an NI instrument. It is imperative to remember to not take the SCXI 1192 Relay Module out of a chassis that is powered on. Doing so may result in harm to the module.
The NI SCXI-1192 has 24 screw-on SMA jacks for the I/O connectors. The relays on this module are latching electromechanical relays with a gold plate contact material. Since this Relay Module has latching relays, there is not a defined power-up state. Instead, the relays will maintain their state in case of power loss. The rest mode of the SCXI-1192 joins NC to COM for every relay. In addition, the NI SCXI-1192 can be utilized to route signals from two RF sources to a single RF measurement instrument. These measurement instruments include a Scope, a Spectrum Analyzer, or a Power Meter.
SCXI-1192 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves.
Model | SCXI-1192 |
---|---|
Manufacturer | National Instruments |
Type | Relay Module |
Configuration | 8-Channel SPDT |
Number of Channels per Relay | 2 |
I/O Connectors | 24 SMA jacks |
Dimensions | 1.2 in. × 6.7 in. × 7.6 in. |
Weight | 2 lb. 7 oz. |
Warranty | 2-3 Year Warranty |
SCXI-1192 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments SCXI-1192 Frequently Asked Questions
Question: How do I test and configure the SCXI-1192?
Answer: To test and configure the SCXI-1192, run measurement and automation explorer (MAX).
Question: What should I do if I get stuck during the configuration or testing of the SCXI 1192?
Answer: If you need help during the configuration process of your SCXI 1192, open the Measurement & Automation Help file.
Question: What is the maximum rated voltage of the switch on the NI SCXI-1192?
Answer: For the NI SCXI-1192, the maximum rated voltage of the switch is 30 V and the maximum rated current is 2 A at 30 V.
SCXI-1192 PDF Manuals & Diagrams
SCXI-1192 PDF Manuals
ARCHIVED NI SCXI-1192 SPECIFICATIONS.PDF
ARCHIVED SCXI 1190 1191 1192 USER MANUAL.PDF
ARCHIVED SCXI 1362 ADAPTER KIT INSTALLATION GUIDE.PDF
ARCHIVED TRADITIONAL NI DAQ USER MANUAL.PDF
NI SWITCHES GETTING STARTED GUIDE FOR NI SCXI SWITCH MODULES.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."