The NI SCXI-1502 (Part Number: 779514-01) is a member of the SCXI Series by National Instruments. This High Performance Thermocouple Module has 32 channels. The SCXI 1502 module can be used with the following operating systems: Windows 7/Vista x64, Windows 7/Vista x86, Windows XP, Windows 2000, LabVIEW Real-Time Phar Lap, and Linux. For these operating systems, the module will work with NI-DAQmx 8.1. This module is not supported by Windows NT or Max OS X.
The National Instruments SCXI-1502 High Performance Thermocouple Module has 32 pins on the front panel. In column A, there are several descriptions for the pins. NC means no connection and RSVD means reserved. The channels are numbered beginning at CH 0 -, then CH 1 –, etc. for column B. Column C starts at CH 0 +, then CH 1 +, etc. For reference, the pin-out can be found in the user manual.
The NI SCXI 1502 module has the capability to be externally calibrated. However, calibration services can no longer be obtained at NI.
SCXI-1502 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves.
Model | SCXI-1502 |
---|---|
Manufacturer | National Instruments |
Part Number | 779514-01 |
Type | High Performance Thermocouple Module |
Channels | 32 |
Driver | NI-DAQmx 8.1 |
Warranty | 2-3 Year Warranty |
SCXI-1502 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the SCXI-1502:
185540K-01, 193640A-01, 193640B-01, 193640C-01L, 779514-01
National Instruments SCXI-1502 Frequently Asked Questions
Question: How do you measure calibration input and output points on the SCXI-1502?
Answer: To measure calibration input and output points on the SCXI-1502, you supply reference signals to the specified physical channel and measure the outputs.
Question: What terminal do you use to measure the module output in the SCXI 1502?
Answer: The terminal that you will use to measure the module output in the SCXI 1502 depends on the configuration of the module in MAX.
Question: Why am I getting a message that says “calhandle in” with the NI SCXI-1502?
Answer: When using the NI SCXI-1502, the reading “calhandle in” is a reference to the calibration session that you created using DAQmx Initialize External Calibration VI.
Driver Downloads for SCXI-1502
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
SCXI-1502
Modular Systems > National Instruments > SCXI
SCXI-1502, 32-Channel, High Performance Thermocouple Module
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Drivers
National Instruments SCXI-1502 High Performance Thermocouple Module
The NI SCXI-1502 (Part Number: 779514-01) is a member of the SCXI Series by National Instruments. This High Performance Thermocouple Module has 32 channels. The SCXI 1502 module can be used with the following operating systems: Windows 7/Vista x64, Windows 7/Vista x86, Windows XP, Windows 2000, LabVIEW Real-Time Phar Lap, and Linux. For these operating systems, the module will work with NI-DAQmx 8.1. This module is not supported by Windows NT or Max OS X.
The National Instruments SCXI-1502 High Performance Thermocouple Module has 32 pins on the front panel. In column A, there are several descriptions for the pins. NC means no connection and RSVD means reserved. The channels are numbered beginning at CH 0 -, then CH 1 –, etc. for column B. Column C starts at CH 0 +, then CH 1 +, etc. For reference, the pin-out can be found in the user manual.
The NI SCXI 1502 module has the capability to be externally calibrated. However, calibration services can no longer be obtained at NI.
SCXI-1502 Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves.
Model | SCXI-1502 |
---|---|
Manufacturer | National Instruments |
Part Number | 779514-01 |
Type | High Performance Thermocouple Module |
Channels | 32 |
Driver | NI-DAQmx 8.1 |
Warranty | 2-3 Year Warranty |
SCXI-1502 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments SCXI-1502 Frequently Asked Questions
Question: How do you measure calibration input and output points on the SCXI-1502?
Answer: To measure calibration input and output points on the SCXI-1502, you supply reference signals to the specified physical channel and measure the outputs.
Question: What terminal do you use to measure the module output in the SCXI 1502?
Answer: The terminal that you will use to measure the module output in the SCXI 1502 depends on the configuration of the module in MAX.
Question: Why am I getting a message that says “calhandle in” with the NI SCXI-1502?
Answer: When using the NI SCXI-1502, the reading “calhandle in” is a reference to the calibration session that you created using DAQmx Initialize External Calibration VI.