Modular Systems > National Instruments > SCXI




Or speak to a sales representative for additional information:
SCXI-2000 In Stock | Ships Today
SCXI-2000, 4-Slot, Chassis
Need an Official Quote?
National Instruments SCXI-2000 Chassis
The NI SCXI-2000 Chassis can hold four SCXI modules maximum. This Chassis is powered with regular AC power and supplies an environment with minimal noise for signal conditioning, providing power, and control circuitry for the SCXI modules. This General-Purpose Chassis can be utilized with current and future SCXI modules, making it a diverse model perfect for users with versatile application demands. There are many types of optional devices which can also be used with the SCXI 2000 to amplify, filter, isolate, and multiplex different signal types, including: thermocouples, resistance temperature detectors, strain gauges, digital I/O signals, analog outputs, current inputs, and high-voltage inputs. There are also cables and terminal blocks with screw terminals, BNC connectors, or thermocouple plugs available to link the user’s modules as well.
The National Instruments SCXI-2000 Chassis comes with the NI-DAQ driver software. NI-DAQ has an expansive library of functions that can be called upon by the user from their application programming settings. Some of the functions included are sequences for analog input, buffered data acquisition, analog output, waveform generation, digital I/O, counter/timer operations, SCXI, RTSI, self-calibration, messaging, and obtaining information to the extended memory.
On the front panel of the NI SCXI-2000, there are status LEDs which specify the Chassis’ activity. There is also an RS-232 connector, a power switch, an indicator light, a reset button, slot 0/power supply, a backplane, DIP switches, module guides, and front threaded strips. On the back panel, there are back threaded strips, a back connector space, a power entry module, a fuse, backplane fuses, a fan and filter, and a voltage selection wheel.
SCXI-2000 Obsolete Status has been announced by National Instruments, but the Chassis will still be available for purchase and repairs by Apex Waves.
Model | SCXI-2000 |
---|---|
Manufacturer | National Instruments |
Type | Chassis |
Module Slots | 4 |
Supported Baud Rates | 300, 600, 1200, 2400, 4800, or 9600 bps; 19.2, 38.4, or 57.6 kbps |
Isolation | RS-485 Port: 42 V |
Connectors | RS-232 and RS-485 |
Weight | 8 lb 8 oz.) |
Warranty | 2-3 Year Warranty |
SCXI-2000 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the SCXI-2000:
1.83039E-26, 1.83039E-28, 18303.5, 18303.9, 183035C-01, 183035D-01, 183035F-01, 183039B-01, 183039C-01, 183039C-31, 183039C-32, 183039C-33, 183039D-01, 183039D-31, 183039D-32, 183039D-33, 183039F-01, 183039F-31, 183039F-32, 183039F-33, 183039G-01, 183039G-31, 183039G-32, 183039G-33, 183039H-01, 183039H-31, 183039H-32, 183039H-33, 183039J-01, 183039J-31, 183039J-32, 183039J-33, 183039K-01, 183039K-31, 183039K-32, 183039K-33, 183091A-01, 777140-01, 777140-02, 777140-03, 777140-04, 777140-05, 777140-06, 777140-07
National Instruments SCXI-2000 Frequently Asked Questions
Question: What is the difference between the two SCXI-2000 part numbers: 183039J-01 and 183039J-31?
Answer: The SCXI-2000 two part numbers are differentiated as follows: 183039J-01 is a basic chassis assembly. 183039J-31 is a 240 VAC SCXI-2000 chassis assembly that includes 183039J-01.
Question: What serial communication ports are built into the NI SCXI-2000?
Answer: The NI SCXI-2000 has built-in RS-232 and RS-485 serial communication ports.
Question: What is the default baud rate of the SCXI 2000?
Answer: The SCXI 2000 has a default baud rate of 9600 bps.
Question: Can you use the NI SCXI-2000 to perform long-distance, multidrop configurations?
Answer: Yes, the NI SCXI-2000 can be used with the RS-485 network for long-distance, multidrop configurations.
SCXI-2000 PDF Manuals
ARCHIVED LABVIEW DATA ACQUISITION BASICS MANUAL.PDF
ARCHIVED LOOKOUT 3.7 ADDENDUM.PDF
ARCHIVED LOOKOUT OBJECT REFERENCE MANUAL.PDF
ARCHIVED LOOKOUT REFERENCE MANUAL.PDF
ARCHIVED NI DAQ USER MANUAL FOR PC COMPATIBLES.PDF
ARCHIVED SCXI 1200 USER MANUAL AND SPECIFICATIONS.PDF
ARCHIVED SCXI 2400 USER MANUAL AND SPECIFICATIONS.PDF
SCXI 1120 D USER MANUAL AND SPECIFICATIONS.PDF
SCXI 1127 1128 USER MANUAL.PDF
SCXI 1371 RACK MOUNT KIT INSTALLATION GUIDE.PDF
SCXI 1372 DUAL RACK MOUNT KIT INSTALLATION GUIDE.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
SCXI-2000
Modular Systems > National Instruments > SCXI
SCXI-2000, 4-Slot, Chassis
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments SCXI-2000 Chassis
The NI SCXI-2000 Chassis can hold four SCXI modules maximum. This Chassis is powered with regular AC power and supplies an environment with minimal noise for signal conditioning, providing power, and control circuitry for the SCXI modules. This General-Purpose Chassis can be utilized with current and future SCXI modules, making it a diverse model perfect for users with versatile application demands. There are many types of optional devices which can also be used with the SCXI 2000 to amplify, filter, isolate, and multiplex different signal types, including: thermocouples, resistance temperature detectors, strain gauges, digital I/O signals, analog outputs, current inputs, and high-voltage inputs. There are also cables and terminal blocks with screw terminals, BNC connectors, or thermocouple plugs available to link the user’s modules as well.
The National Instruments SCXI-2000 Chassis comes with the NI-DAQ driver software. NI-DAQ has an expansive library of functions that can be called upon by the user from their application programming settings. Some of the functions included are sequences for analog input, buffered data acquisition, analog output, waveform generation, digital I/O, counter/timer operations, SCXI, RTSI, self-calibration, messaging, and obtaining information to the extended memory.
On the front panel of the NI SCXI-2000, there are status LEDs which specify the Chassis’ activity. There is also an RS-232 connector, a power switch, an indicator light, a reset button, slot 0/power supply, a backplane, DIP switches, module guides, and front threaded strips. On the back panel, there are back threaded strips, a back connector space, a power entry module, a fuse, backplane fuses, a fan and filter, and a voltage selection wheel.
SCXI-2000 Obsolete Status has been announced by National Instruments, but the Chassis will still be available for purchase and repairs by Apex Waves.
Model | SCXI-2000 |
---|---|
Manufacturer | National Instruments |
Type | Chassis |
Module Slots | 4 |
Supported Baud Rates | 300, 600, 1200, 2400, 4800, or 9600 bps; 19.2, 38.4, or 57.6 kbps |
Isolation | RS-485 Port: 42 V |
Connectors | RS-232 and RS-485 |
Weight | 8 lb 8 oz.) |
Warranty | 2-3 Year Warranty |
SCXI-2000 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments SCXI-2000 Frequently Asked Questions
Question: What is the difference between the two SCXI-2000 part numbers: 183039J-01 and 183039J-31?
Answer: The SCXI-2000 two part numbers are differentiated as follows: 183039J-01 is a basic chassis assembly. 183039J-31 is a 240 VAC SCXI-2000 chassis assembly that includes 183039J-01.
Question: What serial communication ports are built into the NI SCXI-2000?
Answer: The NI SCXI-2000 has built-in RS-232 and RS-485 serial communication ports.
Question: What is the default baud rate of the SCXI 2000?
Answer: The SCXI 2000 has a default baud rate of 9600 bps.
Question: Can you use the NI SCXI-2000 to perform long-distance, multidrop configurations?
Answer: Yes, the NI SCXI-2000 can be used with the RS-485 network for long-distance, multidrop configurations.
SCXI-2000 PDF Manuals & Diagrams
SCXI-2000 PDF Manuals
ARCHIVED LABVIEW DATA ACQUISITION BASICS MANUAL.PDF
ARCHIVED LOOKOUT 3.7 ADDENDUM.PDF
ARCHIVED LOOKOUT OBJECT REFERENCE MANUAL.PDF
ARCHIVED LOOKOUT REFERENCE MANUAL.PDF
ARCHIVED NI DAQ USER MANUAL FOR PC COMPATIBLES.PDF
ARCHIVED SCXI 1200 USER MANUAL AND SPECIFICATIONS.PDF
ARCHIVED SCXI 2400 USER MANUAL AND SPECIFICATIONS.PDF
SCXI 1120 D USER MANUAL AND SPECIFICATIONS.PDF
SCXI 1127 1128 USER MANUAL.PDF
SCXI 1371 RACK MOUNT KIT INSTALLATION GUIDE.PDF
SCXI 1372 DUAL RACK MOUNT KIT INSTALLATION GUIDE.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."