Modular Systems > National Instruments > Serial Interface Devices




Or speak to a sales representative for additional information:
AT-232-4 In Stock | Ships Today
AT-232/4, 4-Port, Serial Interface Card
Need an Official Quote?
National Instruments AT-232/4 Serial Interface
The NI AT-232/4 is a 4-port serial interface. The AT-232/4 is manufactured by National Instruments. The part number of the NI AT-232/4 is 777312-04.
A serial interface enables the user to connect and control external serial hardware, e.g., terminals, modems, and various other devices using asynchronous serial interfaces which support a variety of protocols. Modern serial interface cards have less fault rates, consume less power, and have high data rates.
The NI AT-232/4 Serial Interface can be used as a plug-in card which connects any computer to other serial devices. Each port connects the host equipment to the DTE (Data Terminal Equipment) or DCE (Data Communication Equipment) via registered jacks (RJ45) or modular phone jacks (10-position). The AT-232/4 is compatible with Windows 2000/9x. The AT-232/4 also interrupts sharing between the ports. This serial interface offers an optimum current range of 340 mA to 450 mA at 5V.
A Recommended Standard 232 (RS-232) interface can be used to run the AT-232/4 adapter. To certify error-free decoding of the data at the receiver’s side, the AT-232/4 includes RTS/CTS hardware-handshake lines. The AT-232/4 can be powered on via a USB port; therefore, it doesn’t require any external power. The NI AT-232/4 enables bi-directional data transfer by providing a full-duplex RS-232 port. ISA (Industry Standard Architecture) bus connects to the AT-232/4 adapter. The AT-232/4 has FIFO depth/size of 16B which implies the requirement of 16B of data for buffering. The humidity operating range of the NI AT-232/4 is 10% to 90%.
Model | AT-232/4 |
---|---|
Manufacturer | National Instruments |
Part Number | 777312-04 |
Type | Serial Interface Card |
Data Transfer Rate | 115.2 kbps |
Data Link Protocol | RS-232 |
Number of Ports | 4 |
Current Range at 5V | 340 mA - 450 mA |
Humidity Range Operating | 10 - 90% |
Height | 4.2 in. |
Depth | 6.5 in. |
Warranty | 2-3 Year Warranty |
AT-232/4 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments AT-232/4 Frequently Asked Questions
Question: Is the NI AT-232/4 an isolated serial interface?
Answer: There are versions of the NI AT-232/4 that are isolated and non-isolated.
Question: What is the FIFO size of the AT-232/4?
Answer: The FIFO size of the AT-232/4 is 16 B.
Question: What are the power requirements of the NI AT-232/4?
Answer: The power requirements of the NI AT-232/4 are +5 VDC; 110 mA typical, 150 mA maximum.
AT-232-4 PDF Manuals
ARCHIVED GETTING STARTED WITH YOUR AT SERIAL HARDWARE AND SOFTWARE FOR WINDOWS NT.PDF
ARCHIVED GETTING STARTED WITH YOUR SERIAL HARDWARE AND SOFTWARE FOR WINDOWS NT.PDF
SERIAL QUICK REFERENCE GUIDE.PDF
USING AT SERIAL WITH LINUX.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
AT-232-4
Modular Systems > National Instruments > Serial Interface Devices
AT-232/4, 4-Port, Serial Interface Card
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments AT-232/4 Serial Interface
The NI AT-232/4 is a 4-port serial interface. The AT-232/4 is manufactured by National Instruments. The part number of the NI AT-232/4 is 777312-04.
A serial interface enables the user to connect and control external serial hardware, e.g., terminals, modems, and various other devices using asynchronous serial interfaces which support a variety of protocols. Modern serial interface cards have less fault rates, consume less power, and have high data rates.
The NI AT-232/4 Serial Interface can be used as a plug-in card which connects any computer to other serial devices. Each port connects the host equipment to the DTE (Data Terminal Equipment) or DCE (Data Communication Equipment) via registered jacks (RJ45) or modular phone jacks (10-position). The AT-232/4 is compatible with Windows 2000/9x. The AT-232/4 also interrupts sharing between the ports. This serial interface offers an optimum current range of 340 mA to 450 mA at 5V.
A Recommended Standard 232 (RS-232) interface can be used to run the AT-232/4 adapter. To certify error-free decoding of the data at the receiver’s side, the AT-232/4 includes RTS/CTS hardware-handshake lines. The AT-232/4 can be powered on via a USB port; therefore, it doesn’t require any external power. The NI AT-232/4 enables bi-directional data transfer by providing a full-duplex RS-232 port. ISA (Industry Standard Architecture) bus connects to the AT-232/4 adapter. The AT-232/4 has FIFO depth/size of 16B which implies the requirement of 16B of data for buffering. The humidity operating range of the NI AT-232/4 is 10% to 90%.
Model | AT-232/4 |
---|---|
Manufacturer | National Instruments |
Part Number | 777312-04 |
Type | Serial Interface Card |
Data Transfer Rate | 115.2 kbps |
Data Link Protocol | RS-232 |
Number of Ports | 4 |
Current Range at 5V | 340 mA - 450 mA |
Humidity Range Operating | 10 - 90% |
Height | 4.2 in. |
Depth | 6.5 in. |
Warranty | 2-3 Year Warranty |
AT-232/4 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments AT-232/4 Frequently Asked Questions
Question: Is the NI AT-232/4 an isolated serial interface?
Answer: There are versions of the NI AT-232/4 that are isolated and non-isolated.
Question: What is the FIFO size of the AT-232/4?
Answer: The FIFO size of the AT-232/4 is 16 B.
Question: What are the power requirements of the NI AT-232/4?
Answer: The power requirements of the NI AT-232/4 are +5 VDC; 110 mA typical, 150 mA maximum.
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"