National Instruments PXIe-8280 PXI Ethernet Interface Module
The PXIe-8280 (Part Number: 788261-01) is a cutting-edge 50-Gigabit remote direct memory access (RDMA) interface designed for PXI Express applications. Featuring a single-slot PXI Express module with a 50-Gigabit Ethernet QSFP28 port, it supports RDMA over Converged Ethernet (RoCE). With a Gen3 x8 PCI Express connection, it ensures high-performance data transfer.
This module draws power from both 3.3 V and 12 V power rails. The current drawn varies depending on the cable connected. With a Passive Direct Connect Cable Type, it typically draws 0.61 A (18.33 W) from the +3.3 V rail and 1.36 A (18.33 W) from the +12 V rail. Using an Optical Cable Type, typical current draws are 1.12 A (20.02 W) for +3.3 V and 1.36 A (20.02 W) for +12 V.
Operating within a temperature range of 0 °C to 55 °C, it is suitable for indoor use. Storage temperature ranges from -40 °C to 71 °C. It operates in humidity conditions ranging from 10% to 90% RH and can be stored in humidity conditions from 5% to 95% RH, both noncondensing. The product is suitable for use in environments with a Pollution Degree of 2 and altitudes of up to 2,000 m.
The PXIe-8280 requires strict environmental requirements. It is capable of withstanding non-operating vibration at 2.4 g RMS and running vibration at 0.3 g RMS between 5 Hz and 500 Hz. With an 11 ms pulse duration, the operating shock tolerance is rated at 30 g, half-sine.
Applications requiring fast data transfer across Ethernet connections are best suited for this interface. Its Mellanox OCP card-based QSFP28 port guarantees dependable connectivity. Applications involving high-performance computing, data center networking, and industrial automation can all benefit from this module.
It is advised to strain-relieve any cables close to input connectors in order to guarantee optimum performance and longevity. Directionality bias should be avoided while applying strain relief. The PXIe-8280 provides a flexible solution for demanding data transfer requirements in a range of industrial and networking contexts thanks to its small form factor and sturdy construction.
Model Name | PXIe-8280 |
---|---|
Part Number | 788261-01 |
Product Type | 50-Gigabit RDMA Interface |
Port Type | QSFP28 port based on Mellanox OCP card |
Data Rate Per Port | Up to 50 GbE |
PXI Express Link Configuration | Gen3 x8 PCI Express connection |
Power Draw (Passive Cable) | (+3.3 V): Typical 0.61 A, Maximum 0.92 A +12 V: Typical 1.36 A, Maximum 2.04 A |
Power Draw (Optical Cable) | (+3.3 V): Typical 1.12 A, Maximum 1.68 A +12 V: Typical 1.36 A, Maximum 2.04 A |
Operating Temperature | 0 °C to 55 °C |
Storage Temperature | -40 °C to 71 °C |
Operating Humidity | 10% RH to 90% RH, noncondensing |
Storage Humidity | 5% RH to 95% RH, noncondensing |
Pollution Degree | 2 |
Maximum Altitude | 2,000 m |
National Instruments PXIe-8280 Frequently Asked Questions
Question: What is the port type for PXIe-8280?
Answer: The PXIe-8280 uses the QSFP28 port based on the Mellanox OCP card.
Question: How do I install the NI PXIe-8280 in a PXI Express chassis?
Answer: The PXIe-8280 is meant for installation in a suitable PXI Express chassis. It takes up one or multiple peripheral slots and links to the chassis backplane, allowing it to communicate with other PXI/PXIe modules.
Question: Can the PXIe-8280 work in temperate regions?
Answer: Yes, it has an operating temperature of 0 °C to 50 °C.
PXIe-8280 PDF Manuals
PXIE 8280 DECLARATION OF CONFORMITY.PDF
PXIE 8280 DIMENSIONAL DRAWINGS.PDF
PXIE 8280 ENVIRONMENTAL AND SAFETY INFORMATION.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-8280
Modular Systems > National Instruments > Serial Interface Devices
PXIe-8280, One QSFP28 Port, 50 Gigabit Data Rate, Remote Direct Memory Access, PXI Ethernet Interface Module
1-800-915-6216
- Description
- Technical Specifications
- Frequently Asked Questions
- Manuals & PDFs
National Instruments PXIe-8280 PXI Ethernet Interface Module
The PXIe-8280 (Part Number: 788261-01) is a cutting-edge 50-Gigabit remote direct memory access (RDMA) interface designed for PXI Express applications. Featuring a single-slot PXI Express module with a 50-Gigabit Ethernet QSFP28 port, it supports RDMA over Converged Ethernet (RoCE). With a Gen3 x8 PCI Express connection, it ensures high-performance data transfer.
This module draws power from both 3.3 V and 12 V power rails. The current drawn varies depending on the cable connected. With a Passive Direct Connect Cable Type, it typically draws 0.61 A (18.33 W) from the +3.3 V rail and 1.36 A (18.33 W) from the +12 V rail. Using an Optical Cable Type, typical current draws are 1.12 A (20.02 W) for +3.3 V and 1.36 A (20.02 W) for +12 V.
Operating within a temperature range of 0 °C to 55 °C, it is suitable for indoor use. Storage temperature ranges from -40 °C to 71 °C. It operates in humidity conditions ranging from 10% to 90% RH and can be stored in humidity conditions from 5% to 95% RH, both noncondensing. The product is suitable for use in environments with a Pollution Degree of 2 and altitudes of up to 2,000 m.
The PXIe-8280 requires strict environmental requirements. It is capable of withstanding non-operating vibration at 2.4 g RMS and running vibration at 0.3 g RMS between 5 Hz and 500 Hz. With an 11 ms pulse duration, the operating shock tolerance is rated at 30 g, half-sine.
Applications requiring fast data transfer across Ethernet connections are best suited for this interface. Its Mellanox OCP card-based QSFP28 port guarantees dependable connectivity. Applications involving high-performance computing, data center networking, and industrial automation can all benefit from this module.
It is advised to strain-relieve any cables close to input connectors in order to guarantee optimum performance and longevity. Directionality bias should be avoided while applying strain relief. The PXIe-8280 provides a flexible solution for demanding data transfer requirements in a range of industrial and networking contexts thanks to its small form factor and sturdy construction.
Model Name | PXIe-8280 |
---|---|
Part Number | 788261-01 |
Product Type | 50-Gigabit RDMA Interface |
Port Type | QSFP28 port based on Mellanox OCP card |
Data Rate Per Port | Up to 50 GbE |
PXI Express Link Configuration | Gen3 x8 PCI Express connection |
Power Draw (Passive Cable) | (+3.3 V): Typical 0.61 A, Maximum 0.92 A +12 V: Typical 1.36 A, Maximum 2.04 A |
Power Draw (Optical Cable) | (+3.3 V): Typical 1.12 A, Maximum 1.68 A +12 V: Typical 1.36 A, Maximum 2.04 A |
Operating Temperature | 0 °C to 55 °C |
Storage Temperature | -40 °C to 71 °C |
Operating Humidity | 10% RH to 90% RH, noncondensing |
Storage Humidity | 5% RH to 95% RH, noncondensing |
Pollution Degree | 2 |
Maximum Altitude | 2,000 m |
National Instruments PXIe-8280 Frequently Asked Questions
Question: What is the port type for PXIe-8280?
Answer: The PXIe-8280 uses the QSFP28 port based on the Mellanox OCP card.
Question: How do I install the NI PXIe-8280 in a PXI Express chassis?
Answer: The PXIe-8280 is meant for installation in a suitable PXI Express chassis. It takes up one or multiple peripheral slots and links to the chassis backplane, allowing it to communicate with other PXI/PXIe modules.
Question: Can the PXIe-8280 work in temperate regions?
Answer: Yes, it has an operating temperature of 0 °C to 50 °C.
PXIe-8280 PDF Manuals & Diagrams
PXIe-8280 PDF Manuals
PXIE 8280 DECLARATION OF CONFORMITY.PDF
PXIE 8280 DIMENSIONAL DRAWINGS.PDF
PXIE 8280 ENVIRONMENTAL AND SAFETY INFORMATION.PDF