National Instruments USB-485/4 Serial Interface Device
The USB-485/4 (Part Numbers: 778476-104, 778476-94, 778476-54, 778476-44, 778476-14) is a 4-Port version of the Serial Interface Device by National Instruments. This device can be installed as a standard serial port. The user’s existing application allows the device to be installed with ease. The user can also install the device with applications written with NI-VISA. This instrument allows the user to transform a USB port into an ASP port. This transformation makes communication with serial devices possible. The NI USB-485/4 has a DB-9 male I/O connector. This Serial Interface Device’s case material is made of hard plastic with a metal baseplate.
The USB-485/4 enables users to communicate with multiple devices at a time. A data transfer rate of 460.8 kb/s is another great feature of this device. The National Instruments USB-485/4 also offers effective Discharge Protection. This Discharge Protection is Electrostatic in nature.
The power needs of the NI USB-485/4 Serial Interface Device from an external supply start at 9 Volts. The maximum value of this power requirement is 30 Volts. The typical power requirement is 225 mA. The maximum power need is mA. This Serial Interface Device can handle RTS/CTS hardware handshake lines. This device has an automatic transceiver-control mode as well. This mode is used for 2-wire RS-485 devices. The National Instruments USB-485/4 allows for extensive cable lengths up to 4,000 ft. This hardware has the feature of software-selectable biasing and is compatible with any package with the Microsoft serial driver interface.
Model | USB-485/4 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 778476-104, 778476-94, 778476-54, 778476-44, 778476-14 |
Type | Serial Interface Device |
Ports | 4 |
Supported Serial Protocols | RS-422/RS-485 |
FIFO Size | 128 Bytes |
Dimensions | 8.3 × 4.9 × 1.4 in. |
Weight | 0.83 lb. |
Warranty | 2-3 Year Warranty |
USB-485/4 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated NSNs for the USB-485-4:
5963-01-594-5883 (5963015945883)
National Instruments USB-485/4 Frequently Asked Questions
Question: Why does the USB-485/4 have multiple part numbers?
Answer: The USB-485/4 has several power input options with different part numbers for each one. The first part number, 778476-104, is China 220 VAC. The next part number, 778476-94, is Korea 220 VAC. The third part number, 778476-54, is North America 240 VAC. Next, part number 778476-44 is Universal Euro 240 VAC. Finally, part number 778476-14 is United States 120 VAC.
Question: Which applications is the NI USB-485/4 compatible with?
Answer: The NI USB-485/4 is compatible with any application that utilizes COM ports on Windows OS.
Question: How many devices can the National Instruments USB-485/4 communicate with?
Answer: The National Instruments USB-485/4 can communicate with a maximum of 31 devices.
USB-485-4 PDF Manuals
NI SERIAL HARDWARE SPECIFICATIONS GUIDE.PDF
NI SERIAL HARDWARE SPECIFICATIONS AND FEATURES GUIDE.PDF
SERIAL QUICK REFERENCE GUIDE.PDF
USB SERIAL HARDWARE AND SOFTWARE INSTALLATION GUIDE AND SPECIFICATIONS.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
USB-485-4
Modular Systems > National Instruments > Serial Interface Devices
USB-485/4, 4-Port, RS-485/RS-422 Serial Interface Device
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments USB-485/4 Serial Interface Device
The USB-485/4 (Part Numbers: 778476-104, 778476-94, 778476-54, 778476-44, 778476-14) is a 4-Port version of the Serial Interface Device by National Instruments. This device can be installed as a standard serial port. The user’s existing application allows the device to be installed with ease. The user can also install the device with applications written with NI-VISA. This instrument allows the user to transform a USB port into an ASP port. This transformation makes communication with serial devices possible. The NI USB-485/4 has a DB-9 male I/O connector. This Serial Interface Device’s case material is made of hard plastic with a metal baseplate.
The USB-485/4 enables users to communicate with multiple devices at a time. A data transfer rate of 460.8 kb/s is another great feature of this device. The National Instruments USB-485/4 also offers effective Discharge Protection. This Discharge Protection is Electrostatic in nature.
The power needs of the NI USB-485/4 Serial Interface Device from an external supply start at 9 Volts. The maximum value of this power requirement is 30 Volts. The typical power requirement is 225 mA. The maximum power need is mA. This Serial Interface Device can handle RTS/CTS hardware handshake lines. This device has an automatic transceiver-control mode as well. This mode is used for 2-wire RS-485 devices. The National Instruments USB-485/4 allows for extensive cable lengths up to 4,000 ft. This hardware has the feature of software-selectable biasing and is compatible with any package with the Microsoft serial driver interface.
Model | USB-485/4 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 778476-104, 778476-94, 778476-54, 778476-44, 778476-14 |
Type | Serial Interface Device |
Ports | 4 |
Supported Serial Protocols | RS-422/RS-485 |
FIFO Size | 128 Bytes |
Dimensions | 8.3 × 4.9 × 1.4 in. |
Weight | 0.83 lb. |
Warranty | 2-3 Year Warranty |
USB-485/4 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments USB-485/4 Frequently Asked Questions
Question: Why does the USB-485/4 have multiple part numbers?
Answer: The USB-485/4 has several power input options with different part numbers for each one. The first part number, 778476-104, is China 220 VAC. The next part number, 778476-94, is Korea 220 VAC. The third part number, 778476-54, is North America 240 VAC. Next, part number 778476-44 is Universal Euro 240 VAC. Finally, part number 778476-14 is United States 120 VAC.
Question: Which applications is the NI USB-485/4 compatible with?
Answer: The NI USB-485/4 is compatible with any application that utilizes COM ports on Windows OS.
Question: How many devices can the National Instruments USB-485/4 communicate with?
Answer: The National Instruments USB-485/4 can communicate with a maximum of 31 devices.
USB-485-4 PDF Manuals & Diagrams
USB-485-4 PDF Manuals
NI SERIAL HARDWARE SPECIFICATIONS GUIDE.PDF
NI SERIAL HARDWARE SPECIFICATIONS AND FEATURES GUIDE.PDF
SERIAL QUICK REFERENCE GUIDE.PDF
USB SERIAL HARDWARE AND SOFTWARE INSTALLATION GUIDE AND SPECIFICATIONS.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."