Modular Systems > National Instruments > Serial Interface Devices




Or speak to a sales representative for additional information:
USB-8501 Request for Availablility
USB-8501, 1- or 2-Port, CAN Interface Device
Need an Official Quote?
National Instruments USB-8501 CAN Interface Device
The NI USB-8501 (Part Numbers: 786306-01 and 786307-01) is a Low-Speed/Fault Tolerant Controller Area Network (CAN) Interface Device from National Instruments. This device is fully compatible with the NI-XNET drivers. The USB-8501 is offered in two variations: with one port and with two ports. This device is bus-powered. Thus, you can operate this device by connecting to any standard USB 2.0 port, since it will draw the required power from the host port without needing an external power adapter or power supply.
The NI USB-8501 CAN Interface Device is a viable solution in applications where thousands of CAN signals and CAN frames are involved, such as automation, bus monitoring, control, and more. The DMA engine in the USB-8501 utilizes the integrated processes and onboard hardware resources to move CAN signals and frames between the user program and the interface without putting any stress on the CPU of the host machine. Thus, the NI USB-8501 CAN Interface Device can operate with minimal message latency and without using any hardware resources of the host processor, even while handling the most complicated applications.
The three-pin COMBICON connector on the USB-8501 is provided to let the device synchronize the onboard time-base with various kinds of external devices. Moreover, the COMBICON connector can also be used for external triggering. This CAN Interface Device comes equipped with an NXP TJA1055T transceiver that can operate at a maximum baud rate of 125 Kbps. The above-mentioned synch port is a 5V TTL compatible port. The NI USB-8501 has a 2 meter long captive USB cable.
Model | USB-8501 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 786306-01 and 786307-01 |
Type | CAN Interface Device |
Ports | 1 or 2 |
Bus Connector | USB 2.0 |
CAN Physical Layer | Low-Speed/Fault Tolerant |
Dimensions | 1 Port: 3.30 in. x 4.05 in. x 0.98 in. 2 Ports: 3.65 in. x 4.05 in. x 0.98 in. |
Weight | 1 Port: 7.30 oz. 2 Ports: 7.58 oz. |
Warranty | 2-3 Year Warranty |
USB-8501 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the USB-8501:
147444A-01L, 147444A-02L, 147444B-01L, 147444B-02L, 147447A-01L, 147447A-02L, 147616A-01L, 147616A-02L, 786306-01, 786307-01
Driver Downloads for USB-8501
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
USB-8501
Modular Systems > National Instruments > Serial Interface Devices
USB-8501, 1- or 2-Port, CAN Interface Device
1-800-915-6216
- Description
- Technical Specifications
- Drivers
National Instruments USB-8501 CAN Interface Device
The NI USB-8501 (Part Numbers: 786306-01 and 786307-01) is a Low-Speed/Fault Tolerant Controller Area Network (CAN) Interface Device from National Instruments. This device is fully compatible with the NI-XNET drivers. The USB-8501 is offered in two variations: with one port and with two ports. This device is bus-powered. Thus, you can operate this device by connecting to any standard USB 2.0 port, since it will draw the required power from the host port without needing an external power adapter or power supply.
The NI USB-8501 CAN Interface Device is a viable solution in applications where thousands of CAN signals and CAN frames are involved, such as automation, bus monitoring, control, and more. The DMA engine in the USB-8501 utilizes the integrated processes and onboard hardware resources to move CAN signals and frames between the user program and the interface without putting any stress on the CPU of the host machine. Thus, the NI USB-8501 CAN Interface Device can operate with minimal message latency and without using any hardware resources of the host processor, even while handling the most complicated applications.
The three-pin COMBICON connector on the USB-8501 is provided to let the device synchronize the onboard time-base with various kinds of external devices. Moreover, the COMBICON connector can also be used for external triggering. This CAN Interface Device comes equipped with an NXP TJA1055T transceiver that can operate at a maximum baud rate of 125 Kbps. The above-mentioned synch port is a 5V TTL compatible port. The NI USB-8501 has a 2 meter long captive USB cable.
Model | USB-8501 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 786306-01 and 786307-01 |
Type | CAN Interface Device |
Ports | 1 or 2 |
Bus Connector | USB 2.0 |
CAN Physical Layer | Low-Speed/Fault Tolerant |
Dimensions | 1 Port: 3.30 in. x 4.05 in. x 0.98 in. 2 Ports: 3.65 in. x 4.05 in. x 0.98 in. |
Weight | 1 Port: 7.30 oz. 2 Ports: 7.58 oz. |
Warranty | 2-3 Year Warranty |
USB-8501 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."