National Instruments USRP-2954 USRP Software Defined Radio Device
The USRP-2954 (Part Number: 783153-01) is a USRP Software Defined Radio Device by National Instruments. This device comes equipped with all the necessary hardware and software resources for testing and designing wireless communication systems. The NI USRP-2954 is widely used in a variety of advanced research applications, such as LTE relaying, MIMO (multi-input, multi-output), RF compressive sampling, etc. This device comes equipped with a highly precise internal reference clock which has unmatched synchronization capabilities and frequency accuracy.
The NI USRP-2954 has a fixed Kintex-7 410T FPGA. On this device, there are 2 output channels and 2 input channels available. The two receiving channels or input channels incorporated in the USRP-2954 have a frequency range of 10 MHz to 6 GHz and a gain range of 0 dB to 37.5 dB.
The GPS Disciplined Oscillator (or GPSDO) utilized in the NI USRP-2954 consumes 0.7 watts of power when used with an active antenna. The frequency accuracy of the OCXO depends on several factors. However, you can add an external reference source to achieve superior frequency accuracy for complicated applications where systems should work in tight synchronization.
This USRP Software Defined Radio Device is intended to be operated in indoor environments only and has an operating temperature range of 23 °C ± 5 °C. This device can acquire samples at a rate of up to 200 MS/s I/Q sample rate. The digital-to-analog converter has a SFDR range of 80 dB and operates with a resolution of 16-bits.
Model | USRP-2954 |
---|---|
Manufacturer | National Instruments |
Part Number | 783153-01 |
Type | USRP Software Defined Radio Device |
Input Channels | 2 |
Output Channels | 2 |
RF Frequency Range | 10 MHz to 6 GHz |
Bus Connector | Ethernet, MXIe |
Dimensions | 10.5 in. × 1.6 in. × 8.6 in. |
Weight | 3.50 lb. |
Warranty | 2-3 Year Warranty |
USRP-2954 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the USRP-2954:
156485A-08L, 156485D-08L, 156485E-08L, 156485F-08L, 156485G-08L, 156485H-08L, 156485J-08L, 199856A-08L, 200491A-01, 200820A-01, 783153-01, 786407-01
National Instruments USRP-2954 Frequently Asked Questions
Question: What is the maximum I/Q sample rate of the USRP-2954?
Answer: The maximum IQ sample rate is 200 MS/s
Question: What is the gain range of the USRP-2954?
Answer: The gain range of the USRP-2954 is 0 dB to 31.5 dB
Question: What is the resolution of the USRP-2954's DAC?
Answer: The DAC resolution is 16 bits
USRP-2954 PDF Manuals
MIMO PROTOTYPING SYSTEM GETTING STARTED GUIDE.PDF
NI USRP 2944 USRP-2954 LETTER OF VOLATILITY.PDF
USRP 2950 2952 2953 2954 2955 GETTING STARTED GUIDE.PDF
Driver Downloads for USRP-2954
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
USRP-2954
Modular Systems > National Instruments > USRP Software Defined Radio Devices
USRP-2954, 10 MHz to 6 GHz, USRP Software Defined Radio Device
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
- Drivers
National Instruments USRP-2954 USRP Software Defined Radio Device
The USRP-2954 (Part Number: 783153-01) is a USRP Software Defined Radio Device by National Instruments. This device comes equipped with all the necessary hardware and software resources for testing and designing wireless communication systems. The NI USRP-2954 is widely used in a variety of advanced research applications, such as LTE relaying, MIMO (multi-input, multi-output), RF compressive sampling, etc. This device comes equipped with a highly precise internal reference clock which has unmatched synchronization capabilities and frequency accuracy.
The NI USRP-2954 has a fixed Kintex-7 410T FPGA. On this device, there are 2 output channels and 2 input channels available. The two receiving channels or input channels incorporated in the USRP-2954 have a frequency range of 10 MHz to 6 GHz and a gain range of 0 dB to 37.5 dB.
The GPS Disciplined Oscillator (or GPSDO) utilized in the NI USRP-2954 consumes 0.7 watts of power when used with an active antenna. The frequency accuracy of the OCXO depends on several factors. However, you can add an external reference source to achieve superior frequency accuracy for complicated applications where systems should work in tight synchronization.
This USRP Software Defined Radio Device is intended to be operated in indoor environments only and has an operating temperature range of 23 °C ± 5 °C. This device can acquire samples at a rate of up to 200 MS/s I/Q sample rate. The digital-to-analog converter has a SFDR range of 80 dB and operates with a resolution of 16-bits.
Model | USRP-2954 |
---|---|
Manufacturer | National Instruments |
Part Number | 783153-01 |
Type | USRP Software Defined Radio Device |
Input Channels | 2 |
Output Channels | 2 |
RF Frequency Range | 10 MHz to 6 GHz |
Bus Connector | Ethernet, MXIe |
Dimensions | 10.5 in. × 1.6 in. × 8.6 in. |
Weight | 3.50 lb. |
Warranty | 2-3 Year Warranty |
USRP-2954 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments USRP-2954 Frequently Asked Questions
Question: What is the maximum I/Q sample rate of the USRP-2954?
Answer: The maximum IQ sample rate is 200 MS/s
Question: What is the gain range of the USRP-2954?
Answer: The gain range of the USRP-2954 is 0 dB to 31.5 dB
Question: What is the resolution of the USRP-2954's DAC?
Answer: The DAC resolution is 16 bits
USRP-2954 PDF Manuals & Diagrams
USRP-2954 PDF Manuals
MIMO PROTOTYPING SYSTEM GETTING STARTED GUIDE.PDF
NI USRP 2944 USRP-2954 LETTER OF VOLATILITY.PDF
USRP 2950 2952 2953 2954 2955 GETTING STARTED GUIDE.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."