VXI-1200, 9-slot, FlexFrame VXIbus Mainframe
Need an Official Quote?
National Instruments VXI-1200 FlexFrame VXIbus Mainframe
The VXI-1200 (Part Numbers: 777432-01, 777432-02, 777432-03, 777432-04, 777432-05, 777432-06) is a portable, 5U FlexFrame VXIbus Mainframe produced by National Instruments. The NI VXI-1200 is built with 9 slots. The VXI-1200 is capable of holding a maximum of six C-size VXI modules and as many as three B-size VME or VXI modules. The VXI-1200 is VXIplug&play compatible and complies with the VXIbus Specification Revision 1.4 standards. This VXIbus Mainframe can be used with a plug-in Personality module to enable the B0 or C0 slot to work as the mainframe VXIbus Slot 0 location.
The NI VXI-1200 AC input is auto-frequency and auto-voltage ranging. This FlexFrame VXIbus Mainframe does not necessitate the configuration of a voltage selection switch. The backplane of the VXI-1200 utilizes active-automatic VME interrupt acknowledge and bus grant daisy chaining. Therefore, manually configuring the backplane switch settings and jumpers is not necessary.
The NI VXI-1200 can be used with an adjustable rackmount, which provides varying extensions for rack-mounting configurations. The VXI-1200 has a modular design, allowing the VXIbus Mainframe to be virtually wireless. This FlexFrame VXIbus Mainframe has high MTBF and low MTTR. The VXI-1200 is equipped with fans that have speed control capability. Speed control of the fans helps decrease acoustic noise. The National Instruments VXI-1200 conforms to the safety protocols of EN61010-1. The VXI-1200 is approved by EMI standards with FCC Class A Verified and EC certifications.
VXI-1200 Obsolete Status has been announced by National Instruments, but the mainframe will still be available for purchase and repairs by Apex Waves.
Model | VXI-1200 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 777432-01, 777432-02, 777432-03, 777432-04, 777432-05, 777432-06 |
Type | FlexFrame VXIbus Mainframe |
Input Voltage Range | 90 to 250 VRMS |
Slots | 9 |
Maximum Power Available | 720 W |
Cooling Capacity per Slot | Typically 80 W per slot |
Power Consumption | 1440 W line power maximum |
Dimensions | 14.02 in. x 8.72 in. x 28.32 in. |
Weight | 35 lb. |
Warranty | 2-3 Year Warranty |
VXI-1200 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the VXI-1200:
134380A-01, 134381A-01, 134385A-01, 191200A-01, 191200A-31, 777432-01, 777432-02, 777432-03, 777432-04, 777432-05, 777432-06
National Instruments VXI-1200 Frequently Asked Questions
Question: What is the input frequency range of the VXI-1200?
Answer: The VXI-1200 has an input frequency range of 47 to 440 Hz.
Question: What is the maximum power available to the modules of the VXI-1200?
Answer: The maximum power, under operating temperatures of 0° to 50° C, is 720 W.
Question: How do you access the filter of the VXI-1200?
Answer: The filter of the VXI-1200 can be accessed from the rear of the mainframe
VXI-1200 PDF Manuals
ARCHIVED EMI REDUCTION FOR VXI-1200 FLEXFRAME.PDF
ARCHIVED VXI-1200 USER MANUAL.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
VXI-1200
Modular Systems > National Instruments > VXI and VME
VXI-1200, 9-slot, FlexFrame VXIbus Mainframe
1-800-915-6216
- Description
- Technical Specifications
- FAQ
- Manuals & PDFs
National Instruments VXI-1200 FlexFrame VXIbus Mainframe
The VXI-1200 (Part Numbers: 777432-01, 777432-02, 777432-03, 777432-04, 777432-05, 777432-06) is a portable, 5U FlexFrame VXIbus Mainframe produced by National Instruments. The NI VXI-1200 is built with 9 slots. The VXI-1200 is capable of holding a maximum of six C-size VXI modules and as many as three B-size VME or VXI modules. The VXI-1200 is VXIplug&play compatible and complies with the VXIbus Specification Revision 1.4 standards. This VXIbus Mainframe can be used with a plug-in Personality module to enable the B0 or C0 slot to work as the mainframe VXIbus Slot 0 location.
The NI VXI-1200 AC input is auto-frequency and auto-voltage ranging. This FlexFrame VXIbus Mainframe does not necessitate the configuration of a voltage selection switch. The backplane of the VXI-1200 utilizes active-automatic VME interrupt acknowledge and bus grant daisy chaining. Therefore, manually configuring the backplane switch settings and jumpers is not necessary.
The NI VXI-1200 can be used with an adjustable rackmount, which provides varying extensions for rack-mounting configurations. The VXI-1200 has a modular design, allowing the VXIbus Mainframe to be virtually wireless. This FlexFrame VXIbus Mainframe has high MTBF and low MTTR. The VXI-1200 is equipped with fans that have speed control capability. Speed control of the fans helps decrease acoustic noise. The National Instruments VXI-1200 conforms to the safety protocols of EN61010-1. The VXI-1200 is approved by EMI standards with FCC Class A Verified and EC certifications.
VXI-1200 Obsolete Status has been announced by National Instruments, but the mainframe will still be available for purchase and repairs by Apex Waves.
Model | VXI-1200 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 777432-01, 777432-02, 777432-03, 777432-04, 777432-05, 777432-06 |
Type | FlexFrame VXIbus Mainframe |
Input Voltage Range | 90 to 250 VRMS |
Slots | 9 |
Maximum Power Available | 720 W |
Cooling Capacity per Slot | Typically 80 W per slot |
Power Consumption | 1440 W line power maximum |
Dimensions | 14.02 in. x 8.72 in. x 28.32 in. |
Weight | 35 lb. |
Warranty | 2-3 Year Warranty |
VXI-1200 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments VXI-1200 Frequently Asked Questions
Question: What is the input frequency range of the VXI-1200?
Answer: The VXI-1200 has an input frequency range of 47 to 440 Hz.
Question: What is the maximum power available to the modules of the VXI-1200?
Answer: The maximum power, under operating temperatures of 0° to 50° C, is 720 W.
Question: How do you access the filter of the VXI-1200?
Answer: The filter of the VXI-1200 can be accessed from the rear of the mainframe
VXI-1200 PDF Manuals & Diagrams
VXI-1200 PDF Manuals
ARCHIVED EMI REDUCTION FOR VXI-1200 FLEXFRAME.PDF
ARCHIVED VXI-1200 USER MANUAL.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."