National Instruments PXIe-5110 PXI Oscilloscope
The PXIe-5110 (Part Numbers: 785767-01, 785767-11, 785768-01, and 785768-11) is a PXI Oscilloscope from National Instruments. Designed with a PXIe Bus Connector, this device utilizes a maximum bandwidth of 100 MHz and operates with a sampling rate up to 1 GS/s. Equipped with two simultaneously sampled analog input channels with ground referenced BNC connectors, the oscilloscope is built for a range of applications with a referenced single ended input type.
While all four of the part numbers for the NI PXIe-5110 feature 2 channels, 8 bits of resolution, and a sampling rate of 1 GS/S- they differ in their onboard memory sizes and additional attributes. Both part numbers 785767-01 and 785767-11 have 64 MB of onboard memory, but the latter part variation also includes CableSense technology. Similarly, part numbers 785768-01 and 785768-11 have 512 MB of onboard memory, while the second variation is equipped with CableSense. For those part numbers with CableSense, the pulse voltage is 0.4 V, and the pulse rise time is 4 ns.
The NI PXIe-5110 can be accessed with the NI-SCOPE driver software for the installation of multiple programs, allowing the oscilloscope to be used with various types of application software such as LabWindows/CVI, Measurement Studio, MS-Visual C/C++, LabVIEW, and .NET. The PXI Oscilloscope has both AC and DC input coupling along with multiple triggering modes, making it suitable for both automated and partially automated test applications. Additionally, this device is an excellent choice for high-level synchronization of PXI modules and data throughput.
In terms of power, the current draw for +3.3 V DC is 1.82 A, while the current draw for +12 V DC is 0.83 A. The power draw for each voltage rail is 6 W for +3.3 V DC and 10 W for +12 V DC, for a total of 16 W. The maximum amount of power allowed for the PXIe-5110 is 30 W. With a Gen 1 x4 module form factor, this oscilloscope has an operating temperature range of 0 °C to 55 °C and a storage temperature range of 40 °C to 71 °C.
Model | PXIe-5110 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 785767-01, 785767-11, 785768-01, 785768-11 |
Type | PXI Oscilloscope |
Voltage Input Channels | 2 |
Maximum Sample Rate | 1 GS/s |
Analog Input Resolution | 8 Bits |
Total Maximum Power | 30 W |
Bus Connector Type | PXI Express |
Analog Input Voltage Range | -20 V to 20 V |
Analog Input Impedance | 1 MOhm, 50 Ohm |
Maximum Bandwidth | 100 MHz |
Dimensions | 0.8 in × 5.1 in × 8.5 in. |
Weight | 13.4 oz. |
Warranty | 2-3 Year Warranty |
PXIe-5110 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for the PXIe-5110:
142013A-01L, 142013A-11L, 142013A-31L, 142013A-33L, 142013C-01L, 142013C-11L, 142013D-11L, 147871A-10L, 147871A-110L, 147871A-111L, 147871A-11L, 147871B-10L, 147871B-110L, 147871B-111L, 147871B-11L, 147871C-10L, 200603A-01, 785767-01, 785767-11, 785768-01, 785768-11
National Instruments PXIe-5110 Frequently Asked Questions
Question: What humidity range does the PXIe-5110 Oscilloscope operate with?
Answer: The operating humidity range of the device is 10% to 90% (noncondensing).
Question: What type of analog input does the device have?
Answer: The PXIe-5110 has referenced single-ended analog inputs
Question: What is the timebase frequency of the oscilloscope's onboard clock?
Answer: The internal oscillator onboard clock has a timebase frequency of 500 MHz.
Question: What triggers are supported by the PXIe-5110?
Answer: The PXI Oscilloscope supports Reference (Stop), Reference (Arm), Start, and Advance Triggers.
PXIe-5110 PDF Manuals
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI 5110 5111 5113 LETTER OF VOLATILITY.PDF
PXIE 5110 5111 5113 GETTING STARTED GUIDE.PDF
PXIE 5110 CALIBRATION PROCEDURE.PDF
PXIE 5110 SAFETY ENVIRONMENTAL AND REGULATORY INFORMATION.PDF
Driver Downloads for PXIe-5110
OS Compatibility:
Win XP 32-bit, Win 7 32-bit, Win 10 32-bit
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
PXIe-5110
Oscilloscopes > National Instruments > Oscilloscopes
PXIe-5110, 2 Simultaneously Sampled Channels, 8 Bit Resolution, PXI Oscilloscope
1-800-915-6216
- Description
- Technical Specifications
- FAQs
- Manuals & PDFs
- Drivers
National Instruments PXIe-5110 PXI Oscilloscope
The PXIe-5110 (Part Numbers: 785767-01, 785767-11, 785768-01, and 785768-11) is a PXI Oscilloscope from National Instruments. Designed with a PXIe Bus Connector, this device utilizes a maximum bandwidth of 100 MHz and operates with a sampling rate up to 1 GS/s. Equipped with two simultaneously sampled analog input channels with ground referenced BNC connectors, the oscilloscope is built for a range of applications with a referenced single ended input type.
While all four of the part numbers for the NI PXIe-5110 feature 2 channels, 8 bits of resolution, and a sampling rate of 1 GS/S- they differ in their onboard memory sizes and additional attributes. Both part numbers 785767-01 and 785767-11 have 64 MB of onboard memory, but the latter part variation also includes CableSense technology. Similarly, part numbers 785768-01 and 785768-11 have 512 MB of onboard memory, while the second variation is equipped with CableSense. For those part numbers with CableSense, the pulse voltage is 0.4 V, and the pulse rise time is 4 ns.
The NI PXIe-5110 can be accessed with the NI-SCOPE driver software for the installation of multiple programs, allowing the oscilloscope to be used with various types of application software such as LabWindows/CVI, Measurement Studio, MS-Visual C/C++, LabVIEW, and .NET. The PXI Oscilloscope has both AC and DC input coupling along with multiple triggering modes, making it suitable for both automated and partially automated test applications. Additionally, this device is an excellent choice for high-level synchronization of PXI modules and data throughput.
In terms of power, the current draw for +3.3 V DC is 1.82 A, while the current draw for +12 V DC is 0.83 A. The power draw for each voltage rail is 6 W for +3.3 V DC and 10 W for +12 V DC, for a total of 16 W. The maximum amount of power allowed for the PXIe-5110 is 30 W. With a Gen 1 x4 module form factor, this oscilloscope has an operating temperature range of 0 °C to 55 °C and a storage temperature range of 40 °C to 71 °C.
Model | PXIe-5110 |
---|---|
Manufacturer | National Instruments |
Part Numbers | 785767-01, 785767-11, 785768-01, 785768-11 |
Type | PXI Oscilloscope |
Voltage Input Channels | 2 |
Maximum Sample Rate | 1 GS/s |
Analog Input Resolution | 8 Bits |
Total Maximum Power | 30 W |
Bus Connector Type | PXI Express |
Analog Input Voltage Range | -20 V to 20 V |
Analog Input Impedance | 1 MOhm, 50 Ohm |
Maximum Bandwidth | 100 MHz |
Dimensions | 0.8 in × 5.1 in × 8.5 in. |
Weight | 13.4 oz. |
Warranty | 2-3 Year Warranty |
PXIe-5110 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
National Instruments PXIe-5110 Frequently Asked Questions
Question: What humidity range does the PXIe-5110 Oscilloscope operate with?
Answer: The operating humidity range of the device is 10% to 90% (noncondensing).
Question: What type of analog input does the device have?
Answer: The PXIe-5110 has referenced single-ended analog inputs
Question: What is the timebase frequency of the oscilloscope's onboard clock?
Answer: The internal oscillator onboard clock has a timebase frequency of 500 MHz.
Question: What triggers are supported by the PXIe-5110?
Answer: The PXI Oscilloscope supports Reference (Stop), Reference (Arm), Start, and Advance Triggers.
PXIe-5110 PDF Manuals & Diagrams
PXIe-5110 PDF Manuals
MAINTAIN FORCED AIR COOLING NOTE TO USERS.PDF
NI 5110 5111 5113 LETTER OF VOLATILITY.PDF
PXIE 5110 5111 5113 GETTING STARTED GUIDE.PDF
PXIE 5110 CALIBRATION PROCEDURE.PDF
PXIE 5110 SAFETY ENVIRONMENTAL AND REGULATORY INFORMATION.PDF