Test & Measurement Misc > National Instruments > Terminal Blocks




Or speak to a sales representative for additional information:
CAL-4353 Request for Availablility
CAL-4353, 2 Second Settling Time, 30 g Peak Operating Shock, Terminal Block for Use With the PXIe-4353
Need an Official Quote?
National Instruments CAL-4353 Calibration Terminal Block
The CAL-4353 (Part Number: 781350-01) Front-Mounting Calibration Accessory by National Instruments is an essential tool designed to facilitate precise calibration of the PXIe-4353 32-Channel, 24-Bit PXI Temperature Input Module. This accessory ensures accurate temperature measurements by providing a means to calibrate and verify the performance of the input module.
Because of its intuitive design, the CAL-4353 makes it simple to front-mount, which streamlines the calibration procedure. It provides versatility in calibration methods by being compatible with both 2-wire voltage calibrators and 4-wire resistance calibrators. This accessory has several safety features to guard against malfunctions. The inputs are safeguarded against ±30 VDC to ground and between TC+ and TC–, thereby reducing the possibility of damage during calibration processes.
It is recommended that the CAL-4353 be calibrated on a yearly basis, or more frequently, in order to preserve peak performance. Furthermore, in order to guarantee consistent and accurate results, it is recommended to allow 15 minutes for warm-up prior to beginning calibration processes.
The CAL-4353's compact size and weight of 525 g make it easy to handle and include into calibration setups. Its measurements are 15.28 x 12.95 cm (6.02 × 5.10 in.).
The device is intended to function in an ambient temperature range of 0°C to 55°C and can tolerate non-condensing relative humidity values of 0% to 90%. It is feasible to store food at temperatures between -40°C and 71°C and non-condensing relative humidity levels between 5% and 95%.
The CAL-4353 is designed to fulfill MIL-PRF-28800F Class 2 standards, withstanding shocks up to 30 g peak, half-sine, and 11 ms pulse throughout operation. In order to provide dependability in demanding situations, it also withstands random vibrations in both working and non-operating phases.
Model Name | CAL-4353 |
---|---|
Part Number(s) | 781350-01 |
Manufacturer | National Instruments |
Input Compatibility | 4-wire resistance and 2-wire voltage calibrators |
Protection | ±30 VDC to ground, ±30 VDC between TC+ and TC– |
Calibration Interval | 1 year |
Warm-up Time | 15 minutes |
Dimensions | 15.28 x 12.95 cm (6.02 x 5.10 in.) |
Weight | 525 g (18.5 oz) |
Operating Temperature | 0°C to 55°C |
Operating Humidity | 0% to 90%, non-condensing |
Storage Temperature | -40°C to 71°C |
Storage Humidity | 5% to 95%, non-condensing |
Shock Resistance | 30 g peak, half-sine, 11 ms pulse |
National Instruments CAL-4353 Frequently Asked Questions
Question: What is the role of the CAL-4353 in the PXIe-4353?
Answer: The CAL-4353 Front-Mounting Calibration Accessory facilitates the precise calibration of the PXIe-4353 32-Channel, 24-Bit PXI Temperature Input Module.
Question: Does the CAL-4353 work with other PXIe modules?
Answer: No, it is built specifically for the PXIe-4353.
Question: How many channels does the CAL-4353 have?
Answer: The CAL-4353 features 32 differential analog input channels.
CAL-4353 PDF Manuals
CAL-4353 CALIBRATION PROCEDURE.PDF
CAL-4353 DECLARATION OF CONFORMITY.PDF
CAL-4353 DIMENSIONAL DRAWINGS.PDF
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
CAL-4353
Test & Measurement Misc > National Instruments > Terminal Blocks
CAL-4353, 2 Second Settling Time, 30 g Peak Operating Shock, Terminal Block for Use With the PXIe-4353
1-800-915-6216
- Description
- Technical Specifications
- Frequently Asked Questions
- Manuals & PDFs
National Instruments CAL-4353 Calibration Terminal Block
The CAL-4353 (Part Number: 781350-01) Front-Mounting Calibration Accessory by National Instruments is an essential tool designed to facilitate precise calibration of the PXIe-4353 32-Channel, 24-Bit PXI Temperature Input Module. This accessory ensures accurate temperature measurements by providing a means to calibrate and verify the performance of the input module.
Because of its intuitive design, the CAL-4353 makes it simple to front-mount, which streamlines the calibration procedure. It provides versatility in calibration methods by being compatible with both 2-wire voltage calibrators and 4-wire resistance calibrators. This accessory has several safety features to guard against malfunctions. The inputs are safeguarded against ±30 VDC to ground and between TC+ and TC–, thereby reducing the possibility of damage during calibration processes.
It is recommended that the CAL-4353 be calibrated on a yearly basis, or more frequently, in order to preserve peak performance. Furthermore, in order to guarantee consistent and accurate results, it is recommended to allow 15 minutes for warm-up prior to beginning calibration processes.
The CAL-4353's compact size and weight of 525 g make it easy to handle and include into calibration setups. Its measurements are 15.28 x 12.95 cm (6.02 × 5.10 in.).
The device is intended to function in an ambient temperature range of 0°C to 55°C and can tolerate non-condensing relative humidity values of 0% to 90%. It is feasible to store food at temperatures between -40°C and 71°C and non-condensing relative humidity levels between 5% and 95%.
The CAL-4353 is designed to fulfill MIL-PRF-28800F Class 2 standards, withstanding shocks up to 30 g peak, half-sine, and 11 ms pulse throughout operation. In order to provide dependability in demanding situations, it also withstands random vibrations in both working and non-operating phases.
Model Name | CAL-4353 |
---|---|
Part Number(s) | 781350-01 |
Manufacturer | National Instruments |
Input Compatibility | 4-wire resistance and 2-wire voltage calibrators |
Protection | ±30 VDC to ground, ±30 VDC between TC+ and TC– |
Calibration Interval | 1 year |
Warm-up Time | 15 minutes |
Dimensions | 15.28 x 12.95 cm (6.02 x 5.10 in.) |
Weight | 525 g (18.5 oz) |
Operating Temperature | 0°C to 55°C |
Operating Humidity | 0% to 90%, non-condensing |
Storage Temperature | -40°C to 71°C |
Storage Humidity | 5% to 95%, non-condensing |
Shock Resistance | 30 g peak, half-sine, 11 ms pulse |
National Instruments CAL-4353 Frequently Asked Questions
Question: What is the role of the CAL-4353 in the PXIe-4353?
Answer: The CAL-4353 Front-Mounting Calibration Accessory facilitates the precise calibration of the PXIe-4353 32-Channel, 24-Bit PXI Temperature Input Module.
Question: Does the CAL-4353 work with other PXIe modules?
Answer: No, it is built specifically for the PXIe-4353.
Question: How many channels does the CAL-4353 have?
Answer: The CAL-4353 features 32 differential analog input channels.
CAL-4353 PDF Manuals & Diagrams
CAL-4353 PDF Manuals
CAL-4353 CALIBRATION PROCEDURE.PDF
CAL-4353 DECLARATION OF CONFORMITY.PDF
CAL-4353 DIMENSIONAL DRAWINGS.PDF
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."