Test & Measurement Misc > National Instruments > Terminal Blocks

National Instruments - Terminal Blocks - CAL-9214National Instruments - Terminal Blocks - CAL-9214 - WiringCAL-9214 NewCAL-9214 | Legacy, Refurbished and New Surplus
National Instruments - Terminal Blocks - CAL-9214
National Instruments - Terminal Blocks - CAL-9214 - Wiring
CAL-9214 New
CAL-9214 | Legacy, Refurbished and New Surplus
Same Day Calibration Available
2-3 Year Warranty Included
Free Ground Shipping

Or speak to a sales representative for additional information:


CAL-9214 Request for Availablility

CAL-9214, 23°C ±5°C; RH < 80%, 16 Input Channels, NI Calibration Terminal Block
4.6/5 | 8 ratings
Fast Quote
Quoted Price

Need an Official Quote?

 

National Instruments CAL-9214 Calibration Terminal Block

The CAL-9214 (Part Number: 781771-01) is a National Instruments-designed special-purpose calibration terminal block to be used with the high-precision NI 9214 thermocouple input module. The CAL-9214 is able to perform exacting calibration via solid connections of the 16 channels for thermocouples and 3 for cold-junction compensations in the module. It's the perfect complement that will assure one that an accurate result would be gained by the use of the NI 9214 at temperature measurements.

The CAL-9214 connects directly to the front connector of the NI 9214 and is securely fastened using two jackscrews. The system of connection ensures stability without the slightest chance of interference or loss of signal. The design has a pinout configuration for precision calibration and testing, thus allowing the connection of high-accuracy voltage and resistance calibrators. The CAL-9214 should be correctly installed without overtightening the screws for continued functionality.

This terminal block is critical in calibration and verification procedures. It allows for controlled testing of voltage and resistance across the NI 9214's channels, supporting verification of as-found and as-left conditions. During calibration, the CAL-9214 allows for adjustments to the NI 9214 voltage and CJC channels to meet specified accuracy requirements under defined environmental conditions. It also extends to updating EEPROM for keeping calibration coefficients and settings directly in the module for performance consistency.

The CAL-9214 uses a certain specification in environmental parameters for optimal results. The ambient temperature it requires is 23°C ±5°C; shielded copper wire should be used to reduce noise and thermal offsets. Safety and functionality require not connecting voltages over 10 VDC with the CAL-9214. Extremely robust, the compatibility of a high-precision calibration system like Fluke 5520A makes it an ideal choice in many high-demand industrial and laboratory requirements.

Model NameCAL-9214
Part Number781771-01
Part TypeCalibration Terminal Block
Thermocouple Channels16 Input Channels
CJC Channels3 cold-junction compensation channels
Connection TypeDirect to NI 9214 front connector
Voltage RangeUp to 10 VDC
Environmental Conditions23°C ±5°C; RH < 80%
CompatibilityFor NI 9214 module
Secure MountingDual jackscrews

National Instruments CAL-9214 Frequently Asked Questions

Question: What is the role of the CAL-9214 in the PXIe-9214?

Answer: The CAL-9214 Calibration Terminal Block streamlines the calibration of the NI-9214 module.

Question: Does the CAL-9214 work with other NI modules?

Answer: No, the CAL-9214 is built specifically for the NI 9214.

Question: What calibrators is the CAL-9214 compatible?

Answer: The CAL-9214 is compatible with Fluke 5520A and 5522A calibrators.

  CAL-9214 PDF Manuals


Why Buy From Apex Waves:

Apex Waves Youtube Video

"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."



Delivery:    
UPS, FedEX and DHL – Free Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.net Visa Master Card American Express BB&T Better Business Bureau Dun & Bradstreet
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: Facebook Icon Twitter Icon LinkedIn Icon
Common Typos: CZL-9214, CAP-9214, CAL-9Q14, CAL-9W14, CAL-92Q4

CAL-9214



Test & Measurement Misc > National Instruments > Terminal Blocks

CAL-9214, 23°C ±5°C; RH < 80%, 16 Input Channels, NI Calibration Terminal Block
4.6/5 | 8 ratings

Call now for best pricing
1-800-915-6216

National Instruments CAL-9214 Calibration Terminal Block

The CAL-9214 (Part Number: 781771-01) is a National Instruments-designed special-purpose calibration terminal block to be used with the high-precision NI 9214 thermocouple input module. The CAL-9214 is able to perform exacting calibration via solid connections of the 16 channels for thermocouples and 3 for cold-junction compensations in the module. It's the perfect complement that will assure one that an accurate result would be gained by the use of the NI 9214 at temperature measurements.

The CAL-9214 connects directly to the front connector of the NI 9214 and is securely fastened using two jackscrews. The system of connection ensures stability without the slightest chance of interference or loss of signal. The design has a pinout configuration for precision calibration and testing, thus allowing the connection of high-accuracy voltage and resistance calibrators. The CAL-9214 should be correctly installed without overtightening the screws for continued functionality.

This terminal block is critical in calibration and verification procedures. It allows for controlled testing of voltage and resistance across the NI 9214's channels, supporting verification of as-found and as-left conditions. During calibration, the CAL-9214 allows for adjustments to the NI 9214 voltage and CJC channels to meet specified accuracy requirements under defined environmental conditions. It also extends to updating EEPROM for keeping calibration coefficients and settings directly in the module for performance consistency.

The CAL-9214 uses a certain specification in environmental parameters for optimal results. The ambient temperature it requires is 23°C ±5°C; shielded copper wire should be used to reduce noise and thermal offsets. Safety and functionality require not connecting voltages over 10 VDC with the CAL-9214. Extremely robust, the compatibility of a high-precision calibration system like Fluke 5520A makes it an ideal choice in many high-demand industrial and laboratory requirements.

Model NameCAL-9214
Part Number781771-01
Part TypeCalibration Terminal Block
Thermocouple Channels16 Input Channels
CJC Channels3 cold-junction compensation channels
Connection TypeDirect to NI 9214 front connector
Voltage RangeUp to 10 VDC
Environmental Conditions23°C ±5°C; RH < 80%
CompatibilityFor NI 9214 module
Secure MountingDual jackscrews

National Instruments CAL-9214 Frequently Asked Questions

Question: What is the role of the CAL-9214 in the PXIe-9214?

Answer: The CAL-9214 Calibration Terminal Block streamlines the calibration of the NI-9214 module.

Question: Does the CAL-9214 work with other NI modules?

Answer: No, the CAL-9214 is built specifically for the NI 9214.

Question: What calibrators is the CAL-9214 compatible?

Answer: The CAL-9214 is compatible with Fluke 5520A and 5522A calibrators.

CAL-9214 PDF Manuals & Diagrams

  CAL-9214 PDF Manuals

CAL-9214 DECLARATION OF CONFORMITY.PDF

NI 9214 CALIBRATION PROCEDURE.PDF


Why Buy From Apex Waves

Apex Waves Youtube Video

"The business transaction was super easy and friendly."


"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"


"They were very helpful to get me the test equipment that I need."


Delivery: UPS, FedEX and DHL – Free FedEx Ground on all orders
Overnight, Next Day Air or Expedited shipping options available
International delivery available
Same day shipping for in-stock on location
Warranty: All of our products are covered by our Apex Waves Warranty.
3 Year Warranty - New Surplus Parts
2 Year Warranty - Refurbished Parts
Returns: No hassle return policy.
Dedicated customer service team.
Payment: Authorize.Net paypal visa card master card american express card BB&T Bank better business bureau
Quick Quotes: Receive Price & Availability Today!
Calibration: Ask About Our Tiered Calibration Levels
Option & Modules: Confirm Your Requirements or Versions
Repair: Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Share this page: facebook twitter linkedIn