Test & Measurement Misc > National Instruments > Terminal Blocks




Or speak to a sales representative for additional information:
DR500R-A-160-160 In Stock | Ships Today
CAN Breakout Box, 14 Ports, 7 D-SUB Male Connectors, 197864B-01L, Terminal Block
Need an Official Quote?
National Instruments CAN Breakout Box Terminal Block
The CAN Breakout Box Terminal Block (part number: 197864B-01L) from National Instruments is made for flexible connectivity with PC interfaces or high-, low-, and single-wire Controller Area Network (CAN) devices. Fourteen ports total—seven D-SUB male connectors and seven COMBICON five-pin detachable screw-terminal connections—are included in this breakout box. These ports enable direct wire harness or NI CAN cable connections with ease.
Power can be applied to the V+ pin, which is necessary for some CAN transceivers to operate correctly. This is ensured by an onboard power supply. A switch on the front panel allows users to suit different network requirements by selecting 120 Ω, 60 Ω, or no termination on the network. For convenience, an optional AC adapter is offered. The device supports an input power range of +8 to 30 VDC and outputs +12 VDC on the V+ pin.
The DIN rail mountable CAN Breakout Box makes it simple to integrate into test rigs and cabinets and is appropriate for desktop applications. It's a great option for a variety of industrial and scientific environments because of its adaptability. Because the box supports the same pinouts as all NI CAN interfaces, it can be used widely with high-speed/FD, low-speed, and single-wire CAN networks. This ease of use and consistent performance across many devices are made possible by the compatibility of all NI CAN connections, interfaces, and accessories.
Sturdy construction and useful design components improve the CAN Breakout Box's usage. Its seven screw-terminal plug-equipped COMBICON 5-pin connectors provide safe and simple connections, and its seven D-SUB male connectors follow the CiA-DS-102 pinout standard that is shared by all NI CAN interfaces. A dependable and constant connection framework for several gadgets is ensured by this approach.
Model Name | CAN Breakout Box |
---|---|
Part Number(s) | 197864B-01L |
Part Type | Terminal Block |
Number of Ports | 14 |
Connector Types | 7 D-SUB male connectors, 7 COMBICON 5-pin screw-terminal connectors |
Onboard Power Supply | Accepts +8 to 30 VDC, outputs +12 VDC on V+ pin |
Termination Options | User-selectable: 120 Ω, 60 Ω, or no termination |
Network Compatibility | High-speed/FD, low-speed, and single-wire CAN networks |
Mounting Options | Desktop or DIN rail mountable |
Pinout Standard | CiA-DS-102, compatible with all NI CAN interfaces |
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
DR500R-A-160-160
Test & Measurement Misc > National Instruments > Terminal Blocks
CAN Breakout Box, 14 Ports, 7 D-SUB Male Connectors, 197864B-01L, Terminal Block
1-800-915-6216
- Description
- Technical Specifications
National Instruments CAN Breakout Box Terminal Block
The CAN Breakout Box Terminal Block (part number: 197864B-01L) from National Instruments is made for flexible connectivity with PC interfaces or high-, low-, and single-wire Controller Area Network (CAN) devices. Fourteen ports total—seven D-SUB male connectors and seven COMBICON five-pin detachable screw-terminal connections—are included in this breakout box. These ports enable direct wire harness or NI CAN cable connections with ease.
Power can be applied to the V+ pin, which is necessary for some CAN transceivers to operate correctly. This is ensured by an onboard power supply. A switch on the front panel allows users to suit different network requirements by selecting 120 Ω, 60 Ω, or no termination on the network. For convenience, an optional AC adapter is offered. The device supports an input power range of +8 to 30 VDC and outputs +12 VDC on the V+ pin.
The DIN rail mountable CAN Breakout Box makes it simple to integrate into test rigs and cabinets and is appropriate for desktop applications. It's a great option for a variety of industrial and scientific environments because of its adaptability. Because the box supports the same pinouts as all NI CAN interfaces, it can be used widely with high-speed/FD, low-speed, and single-wire CAN networks. This ease of use and consistent performance across many devices are made possible by the compatibility of all NI CAN connections, interfaces, and accessories.
Sturdy construction and useful design components improve the CAN Breakout Box's usage. Its seven screw-terminal plug-equipped COMBICON 5-pin connectors provide safe and simple connections, and its seven D-SUB male connectors follow the CiA-DS-102 pinout standard that is shared by all NI CAN interfaces. A dependable and constant connection framework for several gadgets is ensured by this approach.
Model Name | CAN Breakout Box |
---|---|
Part Number(s) | 197864B-01L |
Part Type | Terminal Block |
Number of Ports | 14 |
Connector Types | 7 D-SUB male connectors, 7 COMBICON 5-pin screw-terminal connectors |
Onboard Power Supply | Accepts +8 to 30 VDC, outputs +12 VDC on V+ pin |
Termination Options | User-selectable: 120 Ω, 60 Ω, or no termination |
Network Compatibility | High-speed/FD, low-speed, and single-wire CAN networks |
Mounting Options | Desktop or DIN rail mountable |
Pinout Standard | CiA-DS-102, compatible with all NI CAN interfaces |
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."