National Instruments 786848-01 Oscilloscope Probe
Part Number 786848-01 is the identifying part number for the National Instruments CC5002X Oscilloscope Probe. The 786848-01 has a -3 dB bandwidth ranging from DC to 2 MHz. The rise time for the probe is 175 ns or less.The maximum continuous input range is 500 A while the maximum peak current value is non-continuous 50 A. Similarly, the amplitude accuracy is ± 1.0% rdg. ± 5 mV for up to 500A and ± 2.0% rdg. to 700 A peak (DC, and 45 to 66 Hz). Furthermore, the output voltage rate is 0.01 V/A.The noise is equivalent to 25 mA rms or less for a 20 MHz band measuring instrument.
The 786848-01 also has a maximum rated power of 7.2 VA while the supply voltage is ±12 V ±0.5 V. The effect of external magnetic fields is equivalent to 800 mA or less, for DC and 60 Hz input at a magnetic field of 400 A/m. Furthermore, the temperature coefficient of sensitivity is ±2 % rdg or less during input of 50 Hz 500 A within the operating temperature range.
The 786848-01 is recommended for operation between temperatures of 0 °C to 40 °C at a relative humidity of 80% or less. Likewise, it is designed for indoor use only and should be operated within a maximum altitude of 2000 m. On the other hand, it can be stored between -10 °C to 50 °C at the same level of relative humidity. There is a 1 year period of guaranteed accuracy for the probe accounting for opening/closing up to 10000 times.
The diameter of measurable conductors for the 786848-01 is 20 mm. The length of the sensor cable is approximately 2 m while the length of the power supply cable is 1 m. The probe weighs approximately 520 g and comes with an instruction manual and a carrying case. In terms of physical dimensions, the sensor measures 176 W×69H×27 Dmm (approx.) while the terminator measures 27H×55W×18D mm (approx.). It complies with the EN61010 safety and the EN61326 EMC standards.
Part Number | 786848-01 |
---|---|
Model Name | CC5002X |
Part Type | Oscilloscope Probe |
Measure Frequency | 2 MHz |
Probe Type | Current |
Measure Current | 500 A |
Maximum Rated Power | 7.2 VA |
Output Voltage Rate | 0.01 V/A |
Operating Temperature | 0 °C to 40 °C |
Period of Guaranteed Accuracy | 1 year (Opening/closing up to 10000 times) |
Why Buy From Apex Waves:
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"
"They were very helpful to get me the test equipment that I need."
786848-01
Modular Systems > National Instruments > Accessories
786848-01, 2 MHz, 500 A, 0.01 V/A, CC5002X Oscilloscope Probe
1-800-915-6216
- Description
- Technical Specifications
- Manuals & PDFs
National Instruments 786848-01 Oscilloscope Probe
Part Number 786848-01 is the identifying part number for the National Instruments CC5002X Oscilloscope Probe. The 786848-01 has a -3 dB bandwidth ranging from DC to 2 MHz. The rise time for the probe is 175 ns or less.The maximum continuous input range is 500 A while the maximum peak current value is non-continuous 50 A. Similarly, the amplitude accuracy is ± 1.0% rdg. ± 5 mV for up to 500A and ± 2.0% rdg. to 700 A peak (DC, and 45 to 66 Hz). Furthermore, the output voltage rate is 0.01 V/A.The noise is equivalent to 25 mA rms or less for a 20 MHz band measuring instrument.
The 786848-01 also has a maximum rated power of 7.2 VA while the supply voltage is ±12 V ±0.5 V. The effect of external magnetic fields is equivalent to 800 mA or less, for DC and 60 Hz input at a magnetic field of 400 A/m. Furthermore, the temperature coefficient of sensitivity is ±2 % rdg or less during input of 50 Hz 500 A within the operating temperature range.
The 786848-01 is recommended for operation between temperatures of 0 °C to 40 °C at a relative humidity of 80% or less. Likewise, it is designed for indoor use only and should be operated within a maximum altitude of 2000 m. On the other hand, it can be stored between -10 °C to 50 °C at the same level of relative humidity. There is a 1 year period of guaranteed accuracy for the probe accounting for opening/closing up to 10000 times.
The diameter of measurable conductors for the 786848-01 is 20 mm. The length of the sensor cable is approximately 2 m while the length of the power supply cable is 1 m. The probe weighs approximately 520 g and comes with an instruction manual and a carrying case. In terms of physical dimensions, the sensor measures 176 W×69H×27 Dmm (approx.) while the terminator measures 27H×55W×18D mm (approx.). It complies with the EN61010 safety and the EN61326 EMC standards.
Part Number | 786848-01 |
---|---|
Model Name | CC5002X |
Part Type | Oscilloscope Probe |
Measure Frequency | 2 MHz |
Probe Type | Current |
Measure Current | 500 A |
Maximum Rated Power | 7.2 VA |
Output Voltage Rate | 0.01 V/A |
Operating Temperature | 0 °C to 40 °C |
Period of Guaranteed Accuracy | 1 year (Opening/closing up to 10000 times) |
Why Buy From Apex Waves
"The business transaction was super easy and friendly."
"Hand carrying parts to fedex directly to make sure I get them overnight. Great service"